共 2 条
Cross-linked poly-vinyl polymers versus polyureas as designed supports for catalytically active M0 nanoclusters -: Part I.: Nanometer scale structure of the polyurea support EnCat™ 40
被引:8
|作者:
Bolfa, C.
Zoleo, A.
Sassi, A. S.
Maniero, A. L.
Pears, D.
Jerabek, K.
Corain, B.
机构:
[1] Dipartimento Sci Chim, I-35131 Padua, Italy
[2] CNR, Ist Sci & Tecnol Mol, Sez Padova, I-35131 Padua, Italy
[3] Reaxa Ltd, Manchester M9 8ZS, Lancs, England
[4] Acad Sci Czech Republic, Inst Chem Proc Fundamentals, CR-16502 Prague, Czech Republic
关键词:
ESR spectroscopy;
functional resins;
ISEC (inverse steric exclusion chromatography);
water;
THF;
nanopores;
D O I:
10.1016/j.molcata.2007.06.011
中图分类号:
O64 [物理化学(理论化学)、化学物理学];
学科分类号:
070304 ;
081704 ;
摘要:
The cross-linked polymer EnCat (TM) 40 (polyurea) is investigated on the micro-(ESEM) and nanometer scale (ISEC, ESR, C-13 CP MAS NMR) both in the dry (ESEM, C-13 CP MAS NMR) and in the swollen state.(ISEC, ESR, C-13 CP MAS NMR). After swelling with THF or DMF, nanoporous domains featured by ca. 1.2 nm pores are clearly detected with ISEC. ESR analysis based on the evaluation of the rotational mobility of a suitable spin probe dissolved in THF, DMF, MeOH and PhCH3 as swelling media, does qualitatively confirm the presence of nanoporosity also in MeOH- and PhCH3-swollen EnCat (TM) 40. Our manifold analysis reveals the lack of any detectable nanoporosity in water. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 239
页数:7
相关论文