Variable Flip Angle Three-Dimensional Fast Spin-Echo Sequence Combined With Outer Volume Suppression for Imaging Trabecular Bone Structure of the Proximal Femur
被引:30
|
作者:
Han, Misung
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
Han, Misung
[1
]
Chiba, Ko
论文数: 0引用数: 0
h-index: 0
机构:
Nagasaki Univ, Sch Med, Dept Orthopaed Surg, Nagasaki 852, JapanUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
Chiba, Ko
[2
]
Banerjee, Suchandrima
论文数: 0引用数: 0
h-index: 0
机构:
GE Healthcare, Appl Sci Lab, Menlo Pk, CA USAUniv Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
Banerjee, Suchandrima
[3
]
论文数: 引用数:
h-index:
机构:
Carballido-Gamio, Julio
[1
]
论文数: 引用数:
h-index:
机构:
Krug, Roland
[1
]
机构:
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
trabecular bone structure;
3D fast spin echo;
variable flip angle;
proximal femur;
outer volume suppression;
CONFIRMATION BIAS;
D O I:
10.1002/jmri.24673
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
BackgroundTo demonstrate the feasibility of using a variable flip angle three-dimensional fast spin-echo (3D VFA-FSE) sequence combined with outer volume suppression for imaging trabecular bone structure at the proximal femur in vivo at 3 Tesla. MethodsThe 3D VFA-FSE acquisition was optimized to minimize blurring and to provide high signal-to-noise ratio (SNR) from bone marrow. Outer volume suppression was achieved by applying three quadratic-phase radio-frequency pulses. The SNR and trabecular bone structures from 3D VFA-FSE were compared with those from previously demonstrated multiple-acquisition 3D balanced steady-state free precision (bSSFP) using theoretical simulations, ex vivo experiments, and in vivo experiments. ResultsOur simulation demonstrated that 3D VFA-FSE can provide at least 35% higher SNR than 3D bSSFP, which was confirmed by the ex vivo and in vivo experiments. The ex vivo experiments demonstrated a good correlation and agreement between bone structural paramters obtained with the two sequences. The proposed sequence depicted trabecular bone structure at the proxiaml femur in vivo well without visible suppression artifacts and provided a mean SNR of 11.0. ConclusionThe 3D VFA-FSE sequence combined with outer volume suppression can depict the trabecular bone structure of the proximal femur in vivo with minimal blurring and high SNR efficiency. J. Magn. Reson. Imaging 2015;41:1300-1310. (c) 2014 Wiley Periodicals, Inc.