Proposal and assessment of a novel combined heat and power system: Energy, exergy, environmental and economic analysis

被引:79
作者
Ebrahimi-Moghadam, Amir [1 ]
Moghadam, Ali Jabari [1 ]
Farzaneh-Gord, Mahmood [2 ]
Aliakbari, Karim [3 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[2] Ferdowsi Univ Mashhad, Fac Engn, Mech Engn Dept, Mashhad, Razavi Khorasan, Iran
[3] Tech & Vocat Univ, Fac Montazeri, Dept Mech Engn, Khorasan Razavi Branch, Mashhad, Razavi Khorasan, Iran
关键词
Gas turbine cycle; Kalina cycle; Waste heat recovery; Combined heat and power (CHP); 4E analysis; Net present value (NPV); ORGANIC RANKINE-CYCLE; KALINA CYCLE; GAS-TURBINE; WASTE-HEAT; THERMOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; EXERGOECONOMIC ASSESSMENT; PARAMETRIC ANALYSIS; EMPLOYING KALINA; OPTIMIZATION;
D O I
10.1016/j.enconman.2019.112307
中图分类号
O414.1 [热力学];
学科分类号
摘要
This research aims at developing a small-scale novel cogeneration system to satisfy all of the electrical and heating demands of a typical residential complex. The proposed system is integrated of a gas turbine cycle (GTC) and a Kalina cycle (KC). A comprehensive parametric study is presented for evaluating the proposed system from energy, exergy, environmental and economic (4E) points of view. The system's governing equations are solved and validated through developing a high-accuracy computational code in Engineering Equation Solver (EES) software. The effects of some important design parameters (including compressor pressure ratio, base ammonia concentration, generator pressure and condenser pinch point temperature difference) are investigated on four appropriate criteria of energy efficiency (eta(th)), exergy efficiency (eta(ex)), levelized total emissions (LTE) and levelized total costs (LTC). Furthermore, two economic methods, payback period (PP) and net present value (NPV), are also investigated. The results show that, the simulation outputs at base design conditions are as eta(th) = 69.43%, eta(ex) = 37.90%, LTE = 87998 kg/kW, LTC = 8958 $/kW, PP = 3.34 years and NPV = 878679 $. The results of parametric analysis reveal that there is an optimal compressor pressure ratio which leads to maximum eta(th) and eta(ex) and minimum LTE and LTC. The combustion chamber of GTC has the maximum share in system's total exergy destruction (with 55.95% of total exergy destruction). Also, the entire KC has a low contribution of 3.396% in total exergy destruction.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Energy, exergy and economic analysis of a novel geothermal energy system for wastewater and sludge treatment
    Di Fraia, Simona
    Macaluso, Adriano
    Massarotti, Nicola
    Vanoli, Laura
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 195 : 533 - 547
  • [42] Energy and exergy analysis of a closed Brayton cycle-based combined cycle for solar power tower plants
    Zare, V.
    Hasanzadeh, M.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 128 : 227 - 237
  • [43] Energy, exergy, and economic analyses of a novel liquid air and pumped thermal combined energy storage system
    Li, Junxian
    Wang, Zhikang
    Li, Yihong
    Wei, Guqiang
    Ji, Wei
    Fan, Xiaoyu
    Gao, Zhaozhao
    Chen, Liubiao
    Wang, Junjie
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2025, 330
  • [44] Sensitivity analysis of combined cycle parameters on exergy, economic, and environmental of a power plant
    Javadi, M. A.
    Hoseinzadeh, S.
    Ghasemiasl, R.
    Heyns, P. S.
    Chamkha, A. J.
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (01) : 519 - 525
  • [45] Energy-Exergy, Environmental and Economic Criteria in Combined Heat and Power (CHP) Plants: Indexes for the Evaluation of the Cogeneration Potential
    Torchio, Marco F.
    [J]. ENERGIES, 2013, 6 (05): : 2686 - 2708
  • [46] Proposal and assessment of a novel carbon dioxide energy storage system with electrical thermal storage and ejector condensing cycle: Energy and exergy analysis
    Liu, Zhan
    Liu, Zihui
    Xin, Xuan
    Yang, Xiaohu
    [J]. APPLIED ENERGY, 2020, 269
  • [47] Energy, exergy, economic and environmental (4E) analysis of a novel power/refrigeration cascade system to recover low-grade waste heat at 90-150 °C
    Yu, Mengxiao
    Liu, Xiaobin
    Liu, Zhiqiang
    Yang, Sheng
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 363
  • [48] Exergy analysis of gas turbine trigeneration system for combined production of power heat and refrigeration
    Khaliq, Abdul
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03): : 534 - 545
  • [49] Energy, exergy, economic and environmental analysis and optimization of an adiabatic-isothermal compressed air energy storage coupled with methanol decomposition reaction for combined heat, power and hydrogen generation system
    Zhang, Yufei
    Wang, Haiyang
    Zhang, Peiye
    Li, Ruixiong
    Cai, Xuchao
    Zhang, Wenlong
    Wang, Huanran
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2025, 325
  • [50] Energy, exergy and exergy-economic analysis of a new multigeneration system based on double-flash geothermal power plant and solar power tower
    Javadi, Mohammad Amin
    Abhari, Mani Khalili
    Ghasemiasl, Ramin
    Ghomashi, Hossein
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47