Bioanalytical methods for the detection of duloxetine and thioctic acid in plasma using ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS)

被引:2
作者
Wei, Zhuodu [1 ]
Jeong, Hyeon-Cheol [1 ]
Kang, Ye-Ji [1 ,4 ]
Jang, Jaesang [2 ]
Kim, Myoung-Hwan [3 ]
Shin, Kwang-Hee [1 ]
机构
[1] Kyungpook Natl Univ, Coll Pharm, Res Inst Pharmaceut Sci, 80 Daehak Ro, Daegu 41566, South Korea
[2] Korea United Pharm Inc, Seoul 06116, South Korea
[3] NDIC Inc, Preclin Res Ctr, Hwaseong 18469, South Korea
[4] Anim & Plant Quarantine Agcy, Bacterial Dis Div, Gimcheon 39660, South Korea
基金
新加坡国家研究基金会;
关键词
Duloxetine; Thioctic Acid; Liquid Chromatography; Mass Spectrometry; ALPHA-LIPOIC ACID; RAT PLASMA; DIABETIC-NEUROPATHY; LC-MS/MS; VALIDATION; IONIZATION; QUETIAPINE; ASSAY;
D O I
10.12793/tcp.2022.30.e10
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Duloxetine and thioctic acid (TA) are standard drugs for treating diabetic neuropathy, a primary complication associated with diabetes. In this study, ultra performance liquid chromatography coupled with tandem mass spectrometry methods was successfully developed and validated for quantifying duloxetine and TA in biological samples. The protein precipitation method was used to extract duloxetine, TA and their internal standards from beagle dog plasma. A Hypersil Gold C18 column (150 x 2.1 mm, 1.9 mu m) was used for the experiment. Isocratic elution with 0.1% formic acid in acetonitrile (A) and 0.1% formic acid (B) was used for duloxetine, whereas a gradient elution with 0.03% acetic acid (A) and acetonitrile (B) was used for TA. The validated parameters included linearity, sensitivity, accuracy, precision, selectivity, matrix effect, stability, and recovery under different conditions. The linear ranges of the calibration curves for duloxetine and TA were 5-800 ng/mL and 5-1,000 ng/mL, respectively. An intra- and inter-run precision of +/- 15% can be observed in all quality control samples. These methods were successfully used for pharmacokinetics (PKs) studies in beagle dogs to compare PK differences in a fixed-dose combination including duloxetine and TA and co-administration of the 2 drugs.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 50 条
  • [41] Sensitive determination of paroxetine in canine plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Youm, Jeong-Rok
    Lee, Kyung Ryul
    Lee, Hee Joo
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (02) : 138 - 146
  • [42] An ultra-high sensitive bioanalytical method for plasma melatonin by liquid chromatography-tandem mass spectrometry using water as calibration matrix
    Wang, An-Qi
    Wei, Bo-Ping
    Zhang, Yan
    Wang, Yu-Jun
    Xu, Liang
    Lan, Ke
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2259 - 2264
  • [43] Rapid Quantification of Resveratrol in Mouse Plasma by Ultra High Pressure Liquid Chromatography (UPLC) Coupled to Tandem Mass Spectrometry
    Castillo-Pichardo, Linette
    Dharmawardhane, Suranganie
    Rodriguez-Orengo, Jose F.
    [J]. PUERTO RICO HEALTH SCIENCES JOURNAL, 2014, 33 (04) : 151 - 156
  • [44] Analysis of banned veterinary drugs and herbicide residues in shellfish by liquid chromatography-tandem mass spectrometry (LC/MS/MS) and gas chromatography-tandem mass spectrometry (GC/MS/MS)
    Chang, Geng-Ruei
    Chen, Hui-Shan
    Lin, Feng-Yi
    [J]. MARINE POLLUTION BULLETIN, 2016, 113 (1-2) : 579 - 584
  • [45] A liquid chromatography/tandem mass spectrometry assay to quantitate MS-275 in human plasma
    Zhao, Ming
    Rudek, Michelle A.
    Mnasakanyan, Aleksandr
    Hartke, Carol
    Pili, Roberto
    Baker, Sharyn D.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) : 784 - 787
  • [46] Extraction of glucocorticoids from water into acetonitrile using polyol induced extraction with ultra performance liquid chromatography and triple quadrupole mass spectrometry (PIE-UPLC-MS-MS)
    Patel, Shipra
    Snow, Nicholas H.
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (17-20) : 831 - 841
  • [47] A Quantitative Analysis of Memantine in Human Plasma Using Ultra Performance Liquid Chromatography/Tandem Mass Spectrometry
    Dubey, Sunil K.
    Patni, Anil
    Khuroo, Arshad
    Thudi, Nageshwar R.
    Reyar, Simrit
    Kumar, Arun
    Tomar, Manoj S.
    Jain, Rakesh
    Kumar, Nand
    Monif, Tausif
    [J]. E-JOURNAL OF CHEMISTRY, 2009, 6 (04) : 1063 - 1070
  • [48] Novel fast ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and extraction of ethylglucuronide in meconium samples
    Malaca, Sara
    Marchei, Emilia
    Barcelo Martin, Bernardino
    Minutillo, Adele
    Pichini, Simona
    [J]. DRUG TESTING AND ANALYSIS, 2019, 11 (09) : 1471 - 1475
  • [49] Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jain, DS
    Sanyal, M
    Subbaiah, G
    Pande, UC
    Shrivastav, P
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2): : 69 - 74
  • [50] An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma
    Moosavi, Seyed Mojtaba
    Shekar, Kiran
    Fraser, John F.
    Smith, Maree T.
    Ghassabian, Sussan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 : 118 - 122