Bioanalytical methods for the detection of duloxetine and thioctic acid in plasma using ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS)

被引:2
|
作者
Wei, Zhuodu [1 ]
Jeong, Hyeon-Cheol [1 ]
Kang, Ye-Ji [1 ,4 ]
Jang, Jaesang [2 ]
Kim, Myoung-Hwan [3 ]
Shin, Kwang-Hee [1 ]
机构
[1] Kyungpook Natl Univ, Coll Pharm, Res Inst Pharmaceut Sci, 80 Daehak Ro, Daegu 41566, South Korea
[2] Korea United Pharm Inc, Seoul 06116, South Korea
[3] NDIC Inc, Preclin Res Ctr, Hwaseong 18469, South Korea
[4] Anim & Plant Quarantine Agcy, Bacterial Dis Div, Gimcheon 39660, South Korea
基金
新加坡国家研究基金会;
关键词
Duloxetine; Thioctic Acid; Liquid Chromatography; Mass Spectrometry; ALPHA-LIPOIC ACID; RAT PLASMA; DIABETIC-NEUROPATHY; LC-MS/MS; VALIDATION; IONIZATION; QUETIAPINE; ASSAY;
D O I
10.12793/tcp.2022.30.e10
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Duloxetine and thioctic acid (TA) are standard drugs for treating diabetic neuropathy, a primary complication associated with diabetes. In this study, ultra performance liquid chromatography coupled with tandem mass spectrometry methods was successfully developed and validated for quantifying duloxetine and TA in biological samples. The protein precipitation method was used to extract duloxetine, TA and their internal standards from beagle dog plasma. A Hypersil Gold C18 column (150 x 2.1 mm, 1.9 mu m) was used for the experiment. Isocratic elution with 0.1% formic acid in acetonitrile (A) and 0.1% formic acid (B) was used for duloxetine, whereas a gradient elution with 0.03% acetic acid (A) and acetonitrile (B) was used for TA. The validated parameters included linearity, sensitivity, accuracy, precision, selectivity, matrix effect, stability, and recovery under different conditions. The linear ranges of the calibration curves for duloxetine and TA were 5-800 ng/mL and 5-1,000 ng/mL, respectively. An intra- and inter-run precision of +/- 15% can be observed in all quality control samples. These methods were successfully used for pharmacokinetics (PKs) studies in beagle dogs to compare PK differences in a fixed-dose combination including duloxetine and TA and co-administration of the 2 drugs.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 50 条
  • [21] Sensitive Assay of Clenbuterol Residues in Beef by Ultra-High Performance Liquid Chromatography Coupled with Mass Spectrometry (UPLC-MS/MS) and Solid-Phase Extraction
    Martha F. Medellín-Martínez
    Israel Luna-Zavala
    Maricela Martínez-Delgado
    José T. Pérez-Urizar
    Jorge A. Ramírez-Telles
    Omar Patiño-Rodríguez
    Food Analytical Methods, 2018, 11 : 2561 - 2568
  • [22] Sensitive Assay of Clenbuterol Residues in Beef by Ultra-High Performance Liquid Chromatography Coupled with Mass Spectrometry (UPLC-MS/MS) and Solid-Phase Extraction
    Medellin-Martinez, Martha F.
    Luna-Zavala, Israel
    Martinez-Delgado, Maricela
    Perez-Urizar, Jose T.
    Ramirez-Telles, Jorge A.
    Patino-Rodriguez, Omar
    FOOD ANALYTICAL METHODS, 2018, 11 (09) : 2561 - 2568
  • [23] The development and validation of a rapid method for the determination of nitrofurans in honey using high pressure liquid chromatography - tandem mass spectrometry (UPLC-MS-MS)
    Bayer, O. V.
    Yaremchuk, O. S.
    Yevtushenko, T. V.
    Shevchenko, L. V.
    Mykhalska, V. M.
    Dobrozhan, Yu. V.
    Dovhopol, Ya. V.
    Varpikhovskyi, R. L.
    UKRAINIAN JOURNAL OF ECOLOGY, 2018, 8 (01): : 966 - 974
  • [24] Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids
    Keevil, Brian G.
    BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) : 663 - 674
  • [25] Analysis of explosives using ultra performance liquid chromatography (UPLC®) with UV and/or mass spectrometry detection
    Oehrle, Stuart A.
    JOURNAL OF ENERGETIC MATERIALS, 2008, 26 (04) : 197 - 206
  • [26] Determination of Linezolid in Rat Plasma by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry
    Zhang, Lin
    Zheng, Yi
    Wang, Xiaodong
    Zhou, Changsheng
    Jin, Lingxiang
    Pan, Zhenzhen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 : 1130 - 1135
  • [27] Pharmacokinetic Study of Tenacissoside H in Rat Plasma by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry
    Lei, Xuwei
    Zhou, Genzhi
    Fan, Linyu
    Gu, Kaiwen
    Hu, Yue
    Zhang, Mauling
    Yuan, Qian
    Xu, Hongqin
    Zhang, Kaijia
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (03): : 551 - 557
  • [28] ESTIMATION OF MELOXICAM IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS)
    Ganesh, Mani
    Hemalatha, Pushparaj
    Peng, Mei Mei
    Sakthimanigandan, Kalaimani
    Jang, Hyun Tae
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (07) : 867 - 880
  • [29] Development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of ribavirin in human plasma and serum
    Shou, WZ
    Bu, HZ
    Addison, T
    Jiang, XY
    Weng, ND
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (1-2) : 83 - 94
  • [30] Vitamin D metabolite profiling using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jones, Glenville
    Kaufmann, Martin
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2016, 164 : 110 - 114