Field-Weakening Control for Efficiency Optimization in a DFIG Connected to a DC-Link

被引:41
作者
Marques, G. D. [1 ]
Iacchetti, Matteo F. [2 ]
机构
[1] Univ Lisbon, Inst Super Tecn, INESC ID, P-1049001 Lisbon, Portugal
[2] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
关键词
DC grids; dc-link; doubly fed induction generator (DFIG); efficiency improvement; field-weakening; FED INDUCTION GENERATOR; SYNCHRONOUS MOTOR DRIVE; DIODE RECTIFIER; POWER-CONTROL; OPERATION; VOLTAGE; SYSTEM; FLUX; MACHINES; BUS;
D O I
10.1109/TIE.2016.2521603
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The field-weakening operation of a doubly fed induction generator (DFIG) connected to a dc-link is analyzed in this paper, in order to optimize the efficiency. In the considered DFIG-dc system, the stator feeds a constant-voltage dc link by a diode bridge, and the rotor current is controlled using a voltage-source inverter connected to the same dc link. Since the stator voltage amplitude is imposed by the dc-link, a variation in stator flux magnitude results in a frequency change. However, in this system, a stator frequency variation over a wide range can be accepted, if the rated flux is not exceeded. Thus, the stator flux amplitude can be adjusted through the magnetization current component by the voltage-source inverter and according to the load level, in order to reduce losses in the machine and in the inverter. This paper presents an optimization analysis and simplified formulae determining the optimal reference magnetization current in the control of the system. Conversely to field weakening in conventional drives, in this case, the enabling of field weakening control is not dependent on rotor speed, but depends on the reference torque. The proposed optimal control is validated through simulation and experimental results.
引用
收藏
页码:3409 / 3419
页数:11
相关论文
共 28 条
[1]   Advanced control of PWM converter with variable-speed induction generator [J].
Ahmed, Tarek ;
Nishida, Katsumi ;
Nakaoka, Mutsuo .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (04) :934-945
[2]   Parameters and volt-ampere ratings of a synchronous motor drive for flux-weakening applications [J].
Bianchi, N ;
Bolognani, S .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (05) :895-903
[3]   Wide-Speed-Range-Operation Dual Stator-Winding Induction Generator DC Generating System for Wind Power Applications [J].
Bu, Feifei ;
Hu, Yuwen ;
Huang, Wenxin ;
Zhuang, Shenglun ;
Shi, Kai .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) :561-573
[4]  
Gecic M., 2014, SERBIAN J ELECT ENG, V11, P257
[5]   A Novel Control Strategy for a Variable-Speed Wind Turbine With a Permanent-Magnet Synchronous Generator [J].
Haque, Md. Enamul ;
Negnevitsky, Michael ;
Muttaqi, Kashem M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (01) :331-339
[6]   A Scheme for the Power Control in a DFIG Connected to a DC Bus via a Diode Rectifier [J].
Iacchetti, Matteo F. ;
Marques, Gil D. ;
Perini, Roberto .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (03) :1286-1296
[7]   Operation and design issues of a doubly fed induction generator stator connected to a dc net by a diode rectifier [J].
Iacchetti, Matteo F. ;
Marques, Gil D. ;
Perini, Roberto .
IET ELECTRIC POWER APPLICATIONS, 2014, 8 (08) :310-319
[9]   Parametric average-value model of synchronous machine-rectifier systems [J].
Jatskevich, J ;
Pekarek, SD ;
Davoudi, A .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :9-18
[10]   Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution [J].
Kakigano, Hiroaki ;
Miura, Yushi ;
Ise, Toshifumi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (12) :3066-3075