Exergy and Economic Investigation of Different Strategies of Hybrid Systems Consisting of Gas Turbine (GT) and Solid Oxide Fuel Cell (SOFC)

被引:4
作者
Pirkandi, Jamasb [1 ]
Maroufi, Arman [2 ]
Ommian, Mohammad [1 ]
机构
[1] Malek Ashtar Univ Technol, Fac Aerosp, Tehran, Iran
[2] Islamic Azad Univ, Qazvin Branch, Fac Ind & Mech Engn, Qazvin, Iran
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2022年 / 14卷 / 01期
关键词
Hybrid system; micro gas turbine; thermoeconomic; solid oxide fuel cell; PERFORMANCE ANALYSIS; THERMODYNAMIC ANALYSIS; POWER-PLANT; CYCLE; MODEL; OPTIMIZATION;
D O I
10.30880/ijie.2022.14.01.011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Gas turbines and solid oxide fuel cells can be combined in two different strategies to create a new high-efficiency hybrid system. In most hybrid systems, the fuel cell is located directly before the combustion chamber (pressurized type) or after the turbine (atmospheric type). The indirect hybrid system is another compound that has been less studied. In this system, the fuel cell and the gas turbine cycle are located in two separate cycles and heat exchange was done by a heat exchanger. The main purpose of this article is to compare the exergy and economic performance of direct and indirect hybrid systems. The results show that the direct hybrid system with pressurized fuel cell has better performance than the other two types of hybrid system. High electrical efficiency, low rate of irreversibility and pollution, and low cost of electricity generation, as well as appropriate cost of purchase, installation and system setup, are the characteristics of this type of hybrid systems. Analyzes of this study showed that the only positive feature of direct atmospheric fuel cell systems is high production capacity and indirect hybrid systems are less efficient than direct systems.
引用
收藏
页码:127 / 139
页数:13
相关论文
共 28 条
[1]   Electrochemical model for performance analysis of a tubular SOFC [J].
Akkaya, Ali Volkan .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (01) :79-98
[2]   Thermoeconomic modeling and parametric study of hybrid SOFC-gas turbine-steam turbine power plants ranging from 1.5 to 10 MWe [J].
Arsalis, Alexandros .
JOURNAL OF POWER SOURCES, 2008, 181 (02) :313-326
[3]   Macroscopic modeling of solid oxide fuel cell (SOFC) and model-based control of SOFC and gas turbine hybrid system [J].
Bao, Cheng ;
Wang, Ying ;
Feng, Daili ;
Jiang, Zeyi ;
Zhang, Xinxin .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2018, 66 :83-140
[4]  
Bejan A., 1995, Thermal design and optimization
[5]   Hybrid solid oxide fuel cells-gas turbine systems for combined heat and power: A review [J].
Buonomano, Annamaria ;
Calise, Francesco ;
d'Accadia, Massimo Dentice ;
Palombo, Adolfo ;
Vicidomini, Maria .
APPLIED ENERGY, 2015, 156 :32-85
[6]   Modelling of simple hybrid solid oxide fuel cell and gas turbine power plant [J].
Chan, SH ;
Ho, HK ;
Tian, Y .
JOURNAL OF POWER SOURCES, 2002, 109 (01) :111-120
[7]   Thermo-economic optimization of an indirectly coupled solid oxide fuel cell/gas turbine hybrid power plant [J].
Cheddie, Denver F. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (02) :1702-1709
[8]   Thermo-economic modeling of an indirectly coupled solid oxide fuel cell/gas turbine hybrid power plant [J].
Cheddie, Denver F. ;
Murray, Renique .
JOURNAL OF POWER SOURCES, 2010, 195 (24) :8134-8140
[9]   Integration of A Solid Oxide Fuel Cell into A 10 MW Gas Turbine Power Plant [J].
Cheddie, Denver F. .
ENERGIES, 2010, 3 (04) :754-769
[10]   Parametric analysis and optimization for exergoeconomic performance of a combined system based on solid oxide fuel cell-gas turbine and supercritical carbon dioxide Brayton cycle [J].
Chen, Yunru ;
Wang, Meng ;
Liso, Vincenzo ;
Samsatli, Sheila ;
Samsatli, Nouri J. ;
Jing, Rui ;
Chen, Jincan ;
Li, Ning ;
Zhao, Yingru .
ENERGY CONVERSION AND MANAGEMENT, 2019, 186 :66-81