Presurgical finite element analysis from routine computed tomography studies for craniofacial distraction: II. An engineering prediction model for gradual correction of asymmetric skull deformities

被引:26
作者
Remmler, D [1 ]
Olson, L
Duke, D
Ekstrom, CG
Matthews, D
Ullrich, CG
机构
[1] Univ Nebraska, Dept Mech Engn, Walter Scott Engn Ctr N104, Med Ctr, Lincoln, NE 68588 USA
[2] Carolinas Med Ctr, Dept Surg, Charlotte, NC 28203 USA
[3] Carolinas Med Ctr, Dept Radiol, Charlotte, NC 28203 USA
[4] Mayo Clin, Dept Neurol Surg, Coll Engn, Rochester, MN USA
关键词
D O I
10.1097/00006534-199810000-00011
中图分类号
R61 [外科手术学];
学科分类号
摘要
Finite element analysis from routine computed tomography studies (CT/FEA) allows clinicians to predict the mechanical and anatomic consequences of specific distraction systems before human application. A realistic three-dimensional CT/FEA engineering model of an actual plagiocephalic infant with unicoronal synostosis was developed using 4215 parabolic triangular shell elements and intracranial pressure conditions ranging from 10 to 20 mmHg. The completed finite element analysis model was used to predict the anatomic outcome of multiaxial distraction delivered by hypothetical patterns of rod and node distraction units. The predictions for the various patterns of distraction units were also compared quantitatively with respect to force, stress, strain, and intracranial volume. Best anatomic corrections were achieved with bilateral patterns of distraction units that simultaneously elongated the ipsilateral cranium and shortened the contralateral cranium. Greatest strain levels were experienced within the osteotomy callus, greatest stress levels at the appliance anchorage sites, and the greatest rod force at the ipsilateral lower coronal position.
引用
收藏
页码:1395 / 1404
页数:10
相关论文
共 60 条
[1]   AN IMAGING-BASED COMPUTATIONAL AND EXPERIMENTAL-STUDY OF SKULL FRACTURE - FINITE-ELEMENT MODEL DEVELOPMENT [J].
BANDAK, FA ;
VORST, MJV ;
STUHMILLER, LM ;
MLAKAR, PF ;
CHILTON, WE ;
STUHMILLER, JH .
JOURNAL OF NEUROTRAUMA, 1995, 12 (04) :679-688
[2]  
Barone C M, 1993, J Craniofac Surg, V4, P177, DOI 10.1097/00001665-199307000-00013
[3]  
BLINKOV SM, 1968, HUMAN BRAIN FIGURES, P1941
[4]   USE OF DISTRACTION OSTEOGENESIS FOR MAXILLARY ADVANCEMENT - PRELIMINARY-RESULTS [J].
BLOCK, MS ;
BRISTER, GD .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (03) :282-286
[5]   ANTERIOR MAXILLARY ADVANCEMENT USING TOOTH-SUPPORTED DISTRACTION OSTEOGENESIS [J].
BLOCK, MS ;
CERVINI, D ;
CHANG, A ;
GOTTSEGEN, GB .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 53 (05) :561-565
[6]   Le Fort III advancement with gradual distraction using internal devices [J].
Chin, M ;
Toth, BA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (04) :819-830
[7]   Distraction osteogenesis in maxillofacial surgery using internal devices: Review of five cases [J].
Chin, M ;
Toth, BA .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (01) :45-53
[8]   Monobloc distraction osteogenesis during infancy: Report of a case and presentation of a new device [J].
Cohen, SR ;
Boydston, W ;
Burstein, FD ;
Hudgins, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (07) :1919-1924
[9]   Maxillary-midface distraction in children with cleft lip and palate: A preliminary report [J].
Cohen, SR ;
Burstein, FD ;
Stewart, MB ;
Rathburn, MA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (05) :1421-1428
[10]   DISTRACTION OSTEOGENESIS OF THE HUMAN CRANIOFACIAL SKELETON - INITIAL EXPERIENCE WITH A NEW DISTRACTION SYSTEM [J].
COHEN, SR ;
RUTRICK, RE ;
BURSTEIN, FD .
JOURNAL OF CRANIOFACIAL SURGERY, 1995, 6 (05) :368-374