Recurrent scleral patch graft shrinkage and Ahmed valve tube exposure

被引:0
|
作者
Mansoori, Tarannum [1 ]
机构
[1] Anand Eye Inst, Dept Glaucoma, Hyderabad, India
关键词
Silicone oil induced glaucoma; Ahmed Glaucoma Valve; Tube Exposure; Scleral patch graft melt; RISK-FACTORS; GLAUCOMA; COMPLICATIONS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To report a case of recurrent Ahmed glaucoma valve (AGV) tube exposure due to scleral patch graft (SPG) melt Background : AGV is a useful modality in the management of medically refractory glaucoma. Human donor SPG has been employed to cover the external portion of the tube to prevent its exposure. Case Description : A 23 year old male with Anterior chamber intraocular lens (ACIOL) had undergone retinal detachment (RD) surgery with silicone oil insertion (SOI) followed by SO removal (SOR), re- RD and SO re-injection, followed by implantation of Ahmed glaucoma valve (AGV) for uncontrolled glaucoma in the right eye. Three months after the AGV implantation, he presented with exposure of the subconjuctival portion of AGV tube with melted, displaced and shrunk donor sclera graft, which was managed by placing larger sized, full thickness, donor scleral patch graft (SPG) over the exposed tube. Six months later, he presented again with tube exposure and the donor SPG was found to be retracted nasally and shrunk to one fourth of its original size. The AC portion of the tube was blocked by the SO bubble and the emulsified SO could be seen inside the exposed tube. The patient underwent SOR with tube explantation and intraocular pressure was later controlled with transscleral cyclophotocoagulation and medical management. Conclusion : SPG thinning and the overlying conjunctival erosion can occur after the AGV implantation. This can cause AGV tube exposure and hence, long - term patient follow up is essential to ensure timely identification of this possible complication and prompt treatment.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 50 条
  • [41] Repositioning of Ahmed glaucoma valve tube in the anterior chamber with prolene sutures to manage tube-endothelial touch
    Dada, T.
    Gupta, R.
    Tinwala, S., I
    Sobti, A.
    Panda, A.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2012, 4 (02) : 309 - 311
  • [42] Bleb reconstruction using donor scleral patch graft for late bleb leak and hypotony
    O'Rourke, Michael
    Moran, Sarah
    Collins, Niamh
    Doyle, Aoife
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 1039 - 1046
  • [43] Preservation of corneal endothelium after pars plana tube insertion of the Ahmed glaucoma valve
    Chihara, Etsuo
    Umemoto, Mitsuyoshi
    Tanito, Masaki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (02) : 119 - 127
  • [44] Supracapsular fixation for repositioning Ahmed glaucoma valve in case with tube-endothelial touch
    Gupta, Shikha
    Markan, Ashish
    Azmira, Kishan
    Dada, Tanuj
    Gupta, Viney
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (01) : 212 - 216
  • [45] A Novel Technique for Recurrent Tube Exposure Repair
    Kang, J. Minjy
    Hsia, Yen Cheng
    Han, Ying
    CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2020, 2020
  • [46] Serial intracameral visualization of the Ahmed glaucoma valve tube by anterior segment optical coherence tomography
    H-Y Lopilly Park
    K I Jung
    C K Park
    Eye, 2012, 26 : 1256 - 1262
  • [47] Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation
    Byun, Yong Soo
    Lee, Na Young
    Park, Chan Kee
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (02) : 114 - 119
  • [48] Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation
    Yong Soo Byun
    Na Young Lee
    Chan Kee Park
    Japanese Journal of Ophthalmology, 2009, 53 : 114 - 119
  • [49] Effect of Postoperative Trimming of the Tube Portion of Ahmed Glaucoma Valve on Corneal Endothelial Cell Loss
    Lee, Ko Eun
    Sung, Kyung Rim
    Shin, Joong Won
    JOURNAL OF GLAUCOMA, 2022, 31 (02) : 102 - 108
  • [50] Biometric Predictability in Combined Cataract Surgery and Ahmed Glaucoma Valve Implantation Depending on Tube Position
    Marta, Ana
    Coelho, Joao
    Vieira, Rita
    Figueiredo, Ana
    Reis, Rita
    Sampaio, Isabel
    Meneres, Maria Joao
    Meneres, Pedro
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2037 - 2045