Recurrent scleral patch graft shrinkage and Ahmed valve tube exposure

被引:0
|
作者
Mansoori, Tarannum [1 ]
机构
[1] Anand Eye Inst, Dept Glaucoma, Hyderabad, India
关键词
Silicone oil induced glaucoma; Ahmed Glaucoma Valve; Tube Exposure; Scleral patch graft melt; RISK-FACTORS; GLAUCOMA; COMPLICATIONS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To report a case of recurrent Ahmed glaucoma valve (AGV) tube exposure due to scleral patch graft (SPG) melt Background : AGV is a useful modality in the management of medically refractory glaucoma. Human donor SPG has been employed to cover the external portion of the tube to prevent its exposure. Case Description : A 23 year old male with Anterior chamber intraocular lens (ACIOL) had undergone retinal detachment (RD) surgery with silicone oil insertion (SOI) followed by SO removal (SOR), re- RD and SO re-injection, followed by implantation of Ahmed glaucoma valve (AGV) for uncontrolled glaucoma in the right eye. Three months after the AGV implantation, he presented with exposure of the subconjuctival portion of AGV tube with melted, displaced and shrunk donor sclera graft, which was managed by placing larger sized, full thickness, donor scleral patch graft (SPG) over the exposed tube. Six months later, he presented again with tube exposure and the donor SPG was found to be retracted nasally and shrunk to one fourth of its original size. The AC portion of the tube was blocked by the SO bubble and the emulsified SO could be seen inside the exposed tube. The patient underwent SOR with tube explantation and intraocular pressure was later controlled with transscleral cyclophotocoagulation and medical management. Conclusion : SPG thinning and the overlying conjunctival erosion can occur after the AGV implantation. This can cause AGV tube exposure and hence, long - term patient follow up is essential to ensure timely identification of this possible complication and prompt treatment.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 50 条
  • [21] Ahmed tube exposure secondary to Prokera implantation
    Prasher, Pawan
    Lehmann, James D.
    Aggarwal, Nalini K.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (04): : 244 - 245
  • [22] Surgical Outcomes of the Ahmed Valve Implantation Following Trans-scleral Cyclophotocoagulation
    Jeon, Yooyoung
    Kim, Jaeyoung
    Nam, Ki Yup
    Hwang, Young Hoon
    Kim, Kyoung Nam
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (02): : 183 - 190
  • [23] Donor scleral graft vs pericardial graft vs scleral flap in tube drainage covering: advantages and disadvantages
    Silva, Nisa
    Bollemeijer, Jan Geert
    Ferreira, Andre
    Meneres, Maria Joao
    Lemij, Hans
    EXPERT REVIEW OF OPHTHALMOLOGY, 2022, 17 (01) : 1 - 10
  • [24] Modified Scleral Tunnel to Prevent Tube Exposure in Patients With Refractory Glaucoma
    Ma, Xiao-hua
    Du, Xiu-juan
    Liu, Bing
    Bi, Hong-sheng
    JOURNAL OF GLAUCOMA, 2016, 25 (11) : 883 - 885
  • [25] Intraocular Endoscopy Resolved Tube Occlusion of an Ahmed Glaucoma Valve
    Kawashima, Rumi
    Baba, Keita
    Matsushita, Kenji
    Soma, Takeshi
    Kurashige, Masako
    Umeda, Daisuke
    Nakamura, Makoto
    Morii, Eiichi
    Nishida, Kohji
    CASE REPORTS IN OPHTHALMOLOGY, 2021, 12 (02): : 706 - 711
  • [26] Outcomes and Complications of Scleral-Fixated Intraocular Lens Combined with Ahmed Tube Surgery
    Sachdev, Nikhel
    Aquino, Maria Cecilia
    Loon, Seng Chee
    Chan, Yiong Huak
    Chew, Paul
    Koh, Victor
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [27] Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma
    Albis-Donado, Oscar
    Gil-Carrasco, Felix
    Romero-Quijada, Rafael
    Thomas, Ravi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (05) : 365 - 373
  • [28] Posterior migration of Ahmed glaucoma valve tube in a patient with Reiger anomaly: a case report
    Vishnu S Gupta
    Harinder S Sethi
    Malvika Gupta
    Anuj Mehta
    Shivram Singh
    Pankaj Yadav
    KPS Malik
    BMC Ophthalmology, 10
  • [29] Patch graft materials for glaucoma tube implants
    Lind, John T.
    Shute, Thomas S.
    Sheybani, Arsham
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (02) : 194 - 198
  • [30] Outcome of Bleb Revision Using Scleral Patch Graft and Conjunctival Advancement
    Au, Leon
    Wechsler, David
    Spencer, Fiona
    Fenerty, Cecilia
    JOURNAL OF GLAUCOMA, 2009, 18 (04) : 331 - 335