Performance of noninvasive ventilation algorithms on ICU ventilators during pressure support: a clinical study

被引:56
作者
Vignaux, Laurence [1 ,2 ]
Tassaux, Didier [1 ,2 ]
Carteaux, Guillaume [3 ]
Roeseler, Jean [4 ]
Piquilloud, Lise [1 ,2 ]
Brochard, Laurent [3 ,5 ,6 ]
Jolliet, Philippe [7 ,8 ,9 ]
机构
[1] Hop Univ Geneve, Serv Soins Intensifs, Geneva, Switzerland
[2] Univ Geneva, Fac Med, Geneva, Switzerland
[3] Ctr Hosp Albert Chenevier Henri Mondor, AP HP, Creteil, France
[4] Clin Univ St Luc, Serv Soins Intensifs, B-1200 Brussels, Belgium
[5] Hop Henri Mondor, INSERM, U 955, F-94010 Creteil, France
[6] Univ Paris 12, Creteil, France
[7] CHU Vaudois, Serv Med Intens Adulte, Lausanne, Switzerland
[8] CHU Vaudois, Ctr Brules, Lausanne, Switzerland
[9] Univ Lausanne, Fac Biol & Med, Lausanne, Switzerland
关键词
Noninvasive ventilation; Mechanical ventilation; Patient-ventilator interaction; Asynchrony; ACUTE RESPIRATORY-FAILURE; MECHANICAL VENTILATION; ASYNCHRONY;
D O I
10.1007/s00134-010-1994-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.
引用
收藏
页码:2053 / 2059
页数:7
相关论文
共 15 条
  • [1] Antonelli M, 2001, INTENS CARE MED, V27, pS188
  • [2] AIRWAY LEAK SIZE IN NEONATES AND AUTOCYCLING OF 3 FLOW-TRIGGERED VENTILATORS
    BERNSTEIN, G
    KNODEL, E
    HELDT, GP
    [J]. CRITICAL CARE MEDICINE, 1995, 23 (10) : 1739 - 1744
  • [3] NONINVASIVE VENTILATION FOR ACUTE EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    BROCHARD, L
    MANCEBO, J
    WYSOCKI, M
    LOFASO, F
    CONTI, G
    RAUSS, A
    SIMONNEAU, G
    BENITO, S
    GASPARETTO, A
    LEMAIRE, F
    ISABEY, D
    HARF, A
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (13) : 817 - 822
  • [4] Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger
    Calderini, E
    Confalonieri, M
    Puccio, PG
    Francavilla, N
    Stella, L
    Gregoretti, C
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (07) : 662 - 667
  • [5] Noninvasive versus conventional mechanical ventilation - An epidemiologic survey
    Carlucci, A
    Richard, JC
    Wysocki, M
    Lepage, E
    Brochard, L
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (04) : 874 - 880
  • [6] Increased use of noninvasive ventilation in French intensive care units
    Demoule, Alexandre
    Girou, Emmanuelle
    Richard, Jean-Christophe
    Taille, Solenne
    Brochard, Laurent
    [J]. INTENSIVE CARE MEDICINE, 2006, 32 (11) : 1747 - 1755
  • [7] Noninvasive respiratory ventilation in severe hypoxemic failure - A randomized clinical trial
    Ferrer, M
    Esquinas, A
    Leon, M
    Gonzalez, G
    Alarcon, A
    Torres, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (12) : 1438 - 1444
  • [8] Noninvasive ventilation in acute respiratory failure
    Hill, Nicholas S.
    Brennan, John
    Garpestad, Erik
    Nava, Stefano
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (10) : 2402 - 2407
  • [9] Acute applications of noninvasive positive pressure ventilation
    Liesching, T
    Kwok, H
    Hill, NS
    [J]. CHEST, 2003, 124 (02) : 699 - 713
  • [10] Noninvasive ventilation in acute respiratory failure - A meta-analysis update
    Peter, JV
    Moran, JL
    Phillips-Hughes, J
    Warn, D
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (03) : 555 - 562