摘要
Purpose: To compare image quality and diagnostic accuracy of 0.5 molar gadobenate dimeglumine and 1.0 molar gadobutrol in contrast-enhanced (CE) magnetic resonance angiography (MRA) of the lower extremities interindividually. Materials and Methods: The study was approved by our Institutional Review Board. Written informed consent was obtained from all patients before enrollment in the study. We prospectively included 74 patients (21 women, 53 men; mean age +/- SD: 67.9 +/- 11.0 years) with suspected peripheral occlusive vascular disease. All patients underwent a contrast-enhanced MRA of both lower extremities with either 0.1 mL/kg body weight gadobutrol or gadobenate dimeglumine. Image quality. stenosis grade, and artifacts were assessed by two blinded, independent investigators. Signal intensity (SI), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured by a third investigator. Contrast agent groups were compared to each other using a two-sided Student's t-test. Results: The results did not show significant differences for SI. SNR, or CNR. Both investigators were in significant accordance (P < 0.05) with regard to stenosis detection. Conclusion: We conclude that application of standard clinical doses (0.1 mL/kg body weight) of both contrast agents provides similar diagnostic results and gadolinium dose could be reduced by the application of a single dose of gadobenate dimeglumine for CE run-off MRA.
引用
收藏
页码:1166 / 1171
页数:6
相关论文
共 21 条
  • [1] Contrast-enhanced MR angiography of the run-off vasculature: Intraindividual comparison of gadobenate dimeglumine with gadopentetate dimeglumine
    Knopp, MV
    Giesel, FL
    von Tengg-Kobligk, H
    Radeleff, J
    Requardt, M
    Kirchin, MA
    Hentrich, HR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) : 694 - 702
  • [2] Continuously moving table aortoiliofemoral run-off contrast-enhanced magnetic resonance angiography: image quality analysis in comparison to the multistep acquisition
    Asbach, Patrick
    Meade, Michael D.
    Sattenberg, Ronald J.
    Klessen, Christian
    Huppertz, Alexander
    Heidenreich, Jens O.
    ACTA RADIOLOGICA, 2014, 55 (03) : 266 - 272
  • [3] Intraindividual comparison of 1.0 m gadobutrol and 0.5 m gadopentetate dimeglumine for time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the upper torso
    Fink, C
    Puderbach, M
    Ley, S
    Risse, F
    Kuder, TA
    Bock, M
    Thaler, J
    Plathow, C
    Kauczor, HU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 286 - 290
  • [4] Prospective intraindividual comparison of gadoterate and gadobutrol for cervical and intracranial contrast-enhanced magnetic resonance angiography
    Philip Hoelter
    Stefan Lang
    Marina Weibart
    Manuel Schmidt
    Michael F. X. Knott
    Tobias Engelhorn
    Marco Essig
    Stephan Kloska
    Arnd Doerfler
    Neuroradiology, 2017, 59 : 1233 - 1239
  • [5] Prospective intraindividual comparison of gadoterate and gadobutrol for cervical and intracranial contrast-enhanced magnetic resonance angiography
    Hoelter, Philip
    Lang, Stefan
    Weibart, Marina
    Schmidt, Manuel
    Knott, Michael F. X.
    Engelhorn, Tobias
    Essig, Marco
    Kloska, Stephan
    Doerfler, Arnd
    NEURORADIOLOGY, 2017, 59 (12) : 1233 - 1239
  • [6] Intra-individual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraaortic vessels at 3 Tesla
    Bueltmann, Eva
    Erb, Gunter
    Kirchin, Miles A.
    Klose, Uwe
    Naegele, Thomas
    INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 695 - 702
  • [7] First clinical results in a study of contrast enhanced magnetic resonance angiography with the 1.0 molar gadobutrol in peripheral arterial occlusive disease -: Comparison to intraarterial DSA
    Schäfer, FKW
    Schäfer, PJ
    Jahnke, T
    Walluscheck, K
    Priebe, M
    Hentsch, A
    Heller, M
    Brossmann, J
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (04): : 556 - 564
  • [8] Diagnostic accuracy of contrast-enhanced turbo MR angiography of the abdomen, pelvis and lower extremities: Comparison with IADSA
    Sakaguchi, T
    Mitsuzaki, K
    Yamashita, Y
    Ogata, I
    Tang, Y
    Takahashi, M
    RADIOLOGY, 1998, 209P : 458 - 458
  • [9] Dynamic Contrast-Enhanced Magnetic Resonance Imaging Evaluation of VX2 Carcinoma in a Rabbit Model Comparison of 1.0-M Gadobutrol and 0.5-M Gadopentetate Dimeglumine
    Chang, Jung Min
    Moon, Woo Kyung
    Cha, Joo Hee
    Jung, Eun-Jung
    Cho, Nariya
    Kim, Seung Ja
    INVESTIGATIVE RADIOLOGY, 2010, 45 (10) : 655 - 661
  • [10] Intraindividual Quantitative and Qualitative Comparison of Gadopentetate Dimeglumine and Gadobutrol in Time-Resolved Contrast-Enhanced 4-Dimensional Magnetic Resonance Angiography in Minipigs
    Hadizadeh, Dariusch Reza
    Jost, Gregor
    Pietsch, Hubertus
    Weibrecht, Martin
    Perkuhn, Michael
    Boschewitz, Jack Maria
    Keil, Vera Catharina
    Traeber, Frank
    Kukuk, Guido Matthias
    Schild, Hans Heinz
    Willinek, Winfried Albert
    INVESTIGATIVE RADIOLOGY, 2014, 49 (07) : 457 - 464