Linac reported steering error insensitive to 6 MV FFF transverse beam position deviations

被引:1
|
作者
McAloney, Jacob [1 ]
Biggs, Simon [2 ]
Sobolewski, Matthew [1 ,3 ]
机构
[1] Riverina Canc Care Ctr, Wagga Wagga, NSW, Australia
[2] Radiotherapy AI, Wagga Wagga, NSW, Australia
[3] Northern Beaches Canc Care, Frenchs Forest, Australia
关键词
Beam steering; FFF; Radiation field alignment; TECHNOLOGY;
D O I
10.1007/s13246-021-01067-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinically significant beam position deviations were observed for a 6 MV FFF beam during patient specific QA on an Elekta linear accelerator. There was no significant reported transverse steering error from the machine ion chamber, and routine linac QA practices, including cardinal angle Winston-Lutz test, did not identify the deviations. Subsequent investigation using an electronic portal imaging device (EPID) revealed clinically significant beam position deviations for small steering errors. This prompted investigation into further impact and possible solutions. Testing set-points were established by adjusting transverse steering current to achieve introduced 2 T steering errors. Tests at each set-point included scanning water tank profiles and EPID images. A proposed method for adjusting the 2 T error sensitivity was tested via adjusting the 2 T loop parameter such that a reported error corresponds to specific beam position deviations. The testing set-points resulted in positional deviations of greater than 3 mm for reported errors of less than 1. A new method for improving 2 T error sensitivity was implemented. This work has shown that existing vendor protocol for establishing beam steering error for 6 MV FFF beams can lead to beam position deviations without machine interlocks or significant reported steering errors. Thus, an alternative method of establishing steering error sensitivity based on positional deviations is presented.
引用
收藏
页码:1377 / 1382
页数:6
相关论文
共 4 条
  • [1] Linac reported steering error insensitive to 6 MV FFF transverse beam position deviations
    Jacob McAloney
    Simon Biggs
    Matthew Sobolewski
    Physical and Engineering Sciences in Medicine, 2021, 44 : 1377 - 1382
  • [2] Simplified sigmoidal curve fitting for a 6 MV FFF photon beam of the Halcyon to determine the field size for beam commissioning and quality assurance
    Min-Geon Choi
    Martin Law
    Do-Kun Yoon
    Mikoto Tamura
    Kenji Matsumoto
    Masakazu Otsuka
    Moo-Sub Kim
    Shih-Kien Djeng
    Hajime Monzen
    Tae Suk Suh
    Radiation Oncology, 15
  • [3] Simplified sigmoidal curve fitting for a 6 MV FFF photon beam of the Halcyon to determine the field size for beam commissioning and quality assurance
    Choi, Min-Geon
    Law, Martin
    Yoon, Do-Kun
    Tamura, Mikoto
    Matsumoto, Kenji
    Otsuka, Masakazu
    Kim, Moo-Sub
    Djeng, Shih-Kien
    Monzen, Hajime
    Suh, Tae Suk
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [4] Detector Selection Impact on Small-Field Dosimetry of Collecting Beam Data Measurements among Versa HD 6 MV FFF Beams: A Multi-Institutional Variability Analysis
    Ceylan, Cemile
    Gungor, Boran
    Yesil, Abdullah
    Gungor, Sinem
    Inal, Serpil Yondem
    Kara, Esil
    Konuk, Aykut
    Ozden, Ozcan
    Kara, Ozgur
    Avci, Volkan
    Baser, Tamer
    Ugur, Timur
    Saglam, Yucel
    Can, Sumeyra
    Durmus, Ismail Faruk
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (01): : 1 - 18