Measurement of Prepl Pwall factors in electron beams and in a 60Co beam for plane-parallel chambers

被引:11
作者
Ding, GX
Cygler, JE
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Surrey, BC V3V 1Z2, Canada
[2] Ottawa Reg Canc Ctr, Dept Phys Med, Ottawa, ON K1Y 4K7, Canada
关键词
P-repl correction factors; P-wall correction factors; electron beam calibration;
D O I
10.1118/1.598330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper describes a method to measure the product of PreplPwall correction factors for ionization chambers and presents our measured values of PreplPwall for Markus plane-parallel chambers in electron beams. It is shown that the measured values of PreplPwall can be fitted to an equation, PreplPwall = c(1) + c(2)R(50) + c(3)(R-50)(2), for Markus chambers at the new reference depth for electron beams (6 MeV less than or equal to nominal energy E less than or equal to 20 MeV). We also present our measured values of PreplPwall for NACP and Markus chambers in a water phantom irradiated in a Co-60 beam. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1453 / 1457
页数:5
相关论文
共 15 条
[1]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS [J].
ALMOND, PR ;
XU, ZG ;
PARK, HC .
MEDICAL PHYSICS, 1995, 22 (08) :1307-1314
[2]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS - AN EXTENSION OF THE 1983 AAPM PROTOCOL REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-39 [J].
ALMOND, PR ;
ATTIX, FH ;
HUMPHRIES, LJ ;
KUBO, H ;
NATH, R ;
GOETSCH, S ;
ROGERS, DWO .
MEDICAL PHYSICS, 1994, 21 (08) :1251-1260
[3]  
ALMOND PR, 1996, MED PHYS, V23, P1123
[4]   INFLUENCE OF ENERGY AND ANGULAR SPREAD ON STOPPING-POWER RATIOS FOR ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A ;
NAHUM, A ;
MATTSSON, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :751-768
[5]   STOPPING-POWER RATIOS AND THEIR UNCERTAINTIES FOR CLINICAL ELECTRON-BEAM DOSIMETRY [J].
ANDREO, P ;
FRANSSON, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1847-1861
[6]  
[Anonymous], 1983, MED PHYS, V10, P741
[7]   R(50) as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry [J].
Burns, DT ;
Ding, GX ;
Rogers, DWO .
MEDICAL PHYSICS, 1996, 23 (03) :383-388
[8]   CALCULATION OF STOPPING POWER RATIOS USING REALISTIC CLINICAL ELECTRON-BEAMS [J].
DING, GX ;
ROGERS, DWO ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :489-501
[9]  
HANSON F, 1996, MED PHYS, V23, P1124
[10]  
HUG MS, 1997, MED PHYS, V24, P1609