Separation of 248Cm from a 252Cf neutron source for production of Cm targets

被引:0
|
作者
Malmbeck, R
Apostolidis, C
Carlos, R
Glatz, JP
Molinet, R
Morgenstern, A
Nicholl, A
Pagliosa, G
Römer, K
Schädel, M
Sätmark, B
Trautmann, N
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Transuranium Elements, D-76125 Karlsruhe, Germany
[2] Gesell Schwerionenforsch mbH, D-64291 Darmstadt, Germany
[3] Univ Mainz, Inst Kernchem, D-55099 Mainz, Germany
关键词
Cm; Cf; separation; target production; alpha-HIBA; chromatography; UV-Vis absorption spectroscopy;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The separation of milligram amounts of Cm-248 from Cf-252 is presented. Essentially isotopically pure Cm-248 was obtained from an "old" Cf-252 neutron source by acid leaching. Curium was separated from californium in a cation exchange column combining two different eluents: alpha -HMBA at pH 4.0 for Cf, and alpha -HIBA at pH 4.8 for Cm. The method was first tested using Sm and Gd as actinide analogues. Excellent separation was obtained, yielding 12.6 mg Cm (11.9 mg Cm-248) free from Cf (Cf-250 < 1.3 x 10(-2) ng and Cf-252 < 4.2 x 10(-3) ng).
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [41] AN INTERLABORATORY COMPARISON ON THE DETERMINATION OF 241AM, 244CM AND 252CF IN URINE
    Gerstmann, Udo C.
    Taubner, Kerstin
    Hartmann, Martina
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 58 - 62
  • [42] TOF spectrum measurement of 252Cf source fission neutron and gamma ray
    College of Communication Engineering, Chongqing University, Chongqing 400044, China
    不详
    Qiangjiguang Yu Lizishu, 2009, 11 (1719-1723):
  • [43] Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source
    Abbrescia, M
    Altieri, S
    Baratti, V
    Barnabà, O
    Belli, G
    Bruno, G
    Colaleo, A
    DeVecchi, C
    Guida, R
    Iaselli, G
    Imbres, E
    Loddo, F
    Maggi, M
    Marangelli, B
    Musitelli, G
    Nardò, R
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Ratti, S
    Riccardi, C
    Romano, F
    Torre, P
    Vicini, A
    Vitulo, P
    Volpe, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (1-2): : 101 - 109
  • [44] Shielding design studies for a neutron irradiator system based on a 252Cf source
    da Silva, AX
    Crispim, VR
    RADIATION PROTECTION DOSIMETRY, 2001, 95 (04) : 333 - 338
  • [45] New evidence of an intense scission neutron source in the 252Cf spontaneous fission
    Kornilov, NV
    Kagalenko, AB
    Poupko, SV
    Androsenko, PA
    Hambsch, FJ
    NUCLEAR PHYSICS A, 2001, 686 : 187 - 203
  • [46] Determining 252Cf source strength by absolute passive neutron correlation counting
    Croft, S.
    Henzlova, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 714 : 5 - 12
  • [47] Production of neutron deficient isotopes in the multinucleon transfer reaction 48Ca(Elab=5.63 MeV/nucleon) + 248Cm
    Kalandarov, Sh A.
    Adamian, G. G.
    Antonenko, N., V
    Devaraja, H. M.
    Heinz, S.
    PHYSICAL REVIEW C, 2020, 102 (02)
  • [48] Calibration of Spherical Neutron Measuring Devices with a 252Cf Source in the Neutron Calibration Room of the KAERI
    Jun, Sun-Mee
    Kim, Bong-Hwan
    Kim, Jang-Lyul
    Lee, Jai Ki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 286 - 289
  • [49] DETERMINATION OF URANIUM IN SOLUTIONS BY THE NEUTRON ACTIVATION ANALYSIS METHOD WITH 252Cf RADIONUCLIDE NEUTRON SOURCE
    Ivannikov, Sergei I.
    Markin, Nikita S.
    Zheleznov, Veniamin V.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2021, 36 (01): : 12 - 17
  • [50] 157Gd photon dose enhancement from a neutron emitting 252Cf point source
    Rivard, MJ
    Yudelev, M
    Wierzbicki, JG
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1211 - 1217