Paravertebral spinal injection for the treatment of patients with degenerative facet osteoarthropathy: Evidence of motor performance improvements based on objective assessments

被引:6
作者
Toosizadeh, Nima [1 ,2 ]
Harati, Homayoon [2 ]
Yen, Tzu-Chuan [2 ,3 ]
Fastje, Cindy [4 ]
Mohler, Jane [1 ,2 ]
Najafi, Bijan [1 ,2 ,5 ]
Dohm, Michael [4 ]
机构
[1] Univ Arizona, Dept Med, Arizona Ctr Aging, Tucson, AZ USA
[2] Univ Arizona, Coll Med, Dept Surg, Interdisciplinary Consortium Adv Mot Performance, Tucson, AZ USA
[3] Univ Arizona, Coll Med, Dept Physiol, Tucson, AZ 85724 USA
[4] Univ Arizona, Coll Med, Dept Orthopaed Surg, Tucson, AZ USA
[5] Baylor Coll Med, Michael E DeBakey Dept Surg, Interdisciplinary Consortium Adv Mot Performance, Houston, TX 77030 USA
关键词
Spine injection; Low back pain; Motor performance; Wearable technology; Osteoarthropathy; Balance; LOW-BACK-PAIN; EPIDURAL STEROID INJECTION; AMBULATORY SYSTEM; PHYSICAL-ACTIVITY; CONTROLLED-TRIAL; BALANCE; GAIT; DISORDERS; EFFICACY; PARAMETERS;
D O I
10.1016/j.clinbiomech.2016.10.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: This study examined short-and long-term improvements in motor performance, quantified using wearable sensors, in response to facet spine injection in degenerative facet osteoarthropathy patients. Methods: Adults with confirmed degenerative facet osteoarthropathy were recruited and were treated with medial or intermediate branch block injection. Self-report pain, health condition, and disability (Oswestry), as well as objective motor performance measures (gait, balance, and timed-up-and-go) were obtained in five sessions: pre-surgery (baseline), immediately after the injection, one-month, three-month, and 12-month follow-ups. Baseline motor performance parameters were compared with 10 healthy controls. Findings: Thirty patients (age = 50 (14) years) and 10 controls (age = 46 (15) years) were recruited. All motor performance parameters were significantly different between groups. Results showed that average pain and Oswestry scores improved by 51% and 24%, respectively among patients, only one month after injection. Similarly, improvement in motor performance was most noticeable in one-month post-injection measurements; most improvements were observed in gait speed (14% normal walking, P <0.02), hip sway within balance tests (63% eyes-open P <0.01), and turning velocity within the timed-up-and-go test (28%, P<0.02). Better baseline motor performance led to better outcomes in terms of pain relief; baseline turning velocity was 18% faster among the responsive compared to the non-responsive patients. Interpretations: Spinal injection can temporarily (one to three months) improve motor performance in degenerative facet osteoarthropathy patients. Successful pain relief in response to treatment is independent of demographic characteristics and initial pain but dependent on baseline motor performance. Immediate self-reported pain relief is unrelated to magnitude of gradual improvement in motor performance. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 108
页数:9
相关论文
共 53 条
  • [1] Surgical outcome of 438 patients treated surgically for lumbar spinal stenosis
    Airaksinen, O
    Herno, A
    Turunen, V
    Saari, T
    Suomlainen, O
    [J]. SPINE, 1997, 22 (19) : 2278 - 2282
  • [2] Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
    Aminian, K
    Trevisan, C
    Najafi, B
    Dejnabadi, H
    Frigo, C
    Pavan, E
    Telonio, A
    Cerati, F
    Marinoni, EC
    Robert, P
    Leyvraz, PF
    [J]. GAIT & POSTURE, 2004, 20 (01) : 102 - 107
  • [3] Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    Aminian, K
    Najafi, B
    Büla, C
    Leyvraz, PF
    Robert, P
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (05) : 689 - 699
  • [4] The Efficacy of Intramuscular Calcitonin Injection in the Management of Lumbar Spinal Stenosis
    Ashraf, Alireza
    Khodadadi, Mehdi
    Sadraei, Amin
    Naseri, Mahshid
    Nasseri, Ali
    [J]. ASIAN SPINE JOURNAL, 2015, 9 (01) : 75 - 82
  • [5] Immediate Pain Response to Interlaminar Lumbar Epidural Steroid Administration: Response Characteristics and Effects of Anesthetic Concentration
    Bartynski, W. S.
    Jennings, R. B.
    Rothfus, W. E.
    Agarwal, V.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) : 239 - 246
  • [6] EPIDURAL STEROID INJECTIONS FOR LOW-BACK-PAIN AND LUMBOSACRAL RADICULOPATHY
    BENZON, HT
    [J]. PAIN, 1986, 24 (03) : 277 - 295
  • [7] MEASURING THE FUNCTIONAL STATUS OF PATIENTS WITH LOW-BACK-PAIN - ASSESSMENT OF THE QUALITY OF 4 DISEASE-SPECIFIC QUESTIONNAIRES
    BEURSKENS, AJ
    DEVET, HC
    KOKE, AJ
    VANDERHEIJDEN, GJ
    KNIPSCHILD, PG
    [J]. SPINE, 1995, 20 (09) : 1017 - 1028
  • [8] A CONTROLLED TRIAL OF CORTICOSTEROID INJECTIONS INTO FACET JOINTS FOR CHRONIC LOW-BACK-PAIN
    CARETTE, S
    MARCOUX, S
    TRUCHON, R
    GRONDIN, C
    GAGNON, J
    ALLARD, Y
    LATULIPPE, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (14) : 1002 - 1007
  • [9] Clinical predictors of success and failure for lumbar facet radiofrequency denervation
    Cohen, Steven P.
    Hurley, Robert W.
    Christo, Paul J.
    Winkley, James
    Mohiuddin, Meraj M.
    Stojanovic, Milan P.
    [J]. CLINICAL JOURNAL OF PAIN, 2007, 23 (01) : 45 - 52
  • [10] The Oswestry Disability Index
    Fairbank, JCT
    Pynsent, PB
    [J]. SPINE, 2000, 25 (22) : 2940 - 2952