An automatic and accurate registration method for electro-anatomical map and CT surface

被引:5
|
作者
Shu, Lixia [1 ]
Wang, Jin [2 ]
Long, Deyong [2 ]
Lin, Changyan [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, 2 Anzhen Rd, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
基金
北京市自然科学基金;
关键词
atrial fibrillation; catheter navigation; CT; electro-anatomical map; Hausdorff distance; registration; ELECTROANATOMIC MAPPING SYSTEM; ATRIAL-FIBRILLATION; IMAGE INTEGRATION; CATHETER ABLATION; FUSION; CARTOMERGE;
D O I
10.1002/rcs.1818
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Electro-anatomical maps (EAM) and CT surface registration are widely used for catheter navigation in atrial fibrillation ablations. However, few studies have investigated the registration algorithm. Moreover, some of them are semiautomatic, so that physicians must be proficient; some are inaccurate for catheter navigation. A both automatic and accurate registration method is needed. Method: A Hausdorff distance based approach (HD) was proposed for EAM/CT registration. First, using principal axes based registration, EAM/CT pairs were coarsely aligned. Then, using Hausdorff distance as the fine objective function, EAM/CT pairs were finely aligned. Results: Six real EAM/CT pairs were collected from five patients and 38 simulated pairs were generated. Each pair was aligned using Carto-Merge, a stochastic approach (SA) and HD. Considering the balance of operability, accuracy and robustness, HD obtained the best EAM/CT registration results among the three approaches. Conclusion: Experiments validate that the proposed method registers EAM and CT surface both automatically and accurately.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Fully Automatic Registration Method for CARTO Electro-anatomic Map and CT Surface
    Shu, Lixia
    Guan, Yanni
    Long, Deyong
    Yu, Ronghui
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 553 - 556
  • [2] Evaluation of a μCT-based electro-anatomical cochlear implant model
    Cakir, Ahmet
    Dawant, Benoit M.
    Noble, Jack. H.
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [3] Spatio-Temporal Registration of Electro-Anatomical Mappings with Functional Data for CRT Optimization
    Tavard, Francois
    Simon, Antoine
    Hernandez, Alfredo I.
    Betancur, Julian
    Donal, Erwan
    Leclercq, Christophe
    Garreau, Mireille
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 161 - 164
  • [4] Automatic surface registration based on regional curvature map
    Yang, Zhen
    Sun, Jun-Hua
    Zhang, Guang-Jun
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2010, 21 (02): : 245 - 248
  • [5] In-vivo MRI and in-vivo electro-anatomical voltage map characteristics of infarct heterogeneity in a swine model
    Shokrollahi, E.
    Pop, M.
    Safri, M.
    Yang, Y.
    Radau, P. E.
    Barry, J.
    Detsky, J.
    Griffin, G. H.
    Crystal, E.
    Wright, G. A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2792 - 2795
  • [6] A valid registration algorithm for electroanatomic map and CT surface
    Shu, Lixia
    Wang, Jin
    PROCEEDINGS FIRST INTERNATIONAL CONFERENCE ON ELECTRONICS INSTRUMENTATION & INFORMATION SYSTEMS (EIIS 2017), 2017, : 194 - 197
  • [7] Catheter ablation of post-senning atrial tachycardia using CT-guided electro-anatomical mapping
    De Backer, Julie
    Devos, Dan
    Demulier, Laurent
    Duytschaever, Mattias
    ACTA CARDIOLOGICA, 2009, 64 (01) : 126 - 126
  • [8] A Novel Semi-Automatic Method for Accurate Registration of FDG_CT and FLT_CT Image Modalities
    Wang, Xue
    Wang, Zhenzhong
    Wang, Jin
    Cabrerizo, Mercedes
    Adjouadi, Malek
    Goryawala, Mohammed
    Gulec, Seza A.
    2015 IEEE SIGNAL PROCESSING IN MEDICINE AND BIOLOGY SYMPOSIUM (SPMB), 2015,
  • [9] Automated accurate registration method between UAV image and Google satellite map
    Yijie Yuan
    Wei Huang
    Xiangxin Wang
    Huaiyu Xu
    Hongying Zuo
    Ruidan Su
    Multimedia Tools and Applications, 2020, 79 : 16573 - 16591
  • [10] Automated accurate registration method between UAV image and Google satellite map
    Yuan, Yijie
    Huang, Wei
    Wang, Xiangxin
    Xu, Huaiyu
    Zuo, Hongying
    Su, Ruidan
    MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (23-24) : 16573 - 16591