Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length

被引:3
作者
Choi, Bohm [2 ]
Lee, Dong-Ok
Mo, Sung-Seo [3 ]
Kim, Seong-Hun [4 ]
Park, Ki-Ho [4 ]
Chung, Kyu-Rhim [5 ]
Nelson, Gerald [6 ]
Han, Seong Ho [1 ]
机构
[1] Catholic Univ Korea, St Vincent Hosp, Dept Orthodont, Suwon 442723, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Dept Prosthodont, Suwon 442723, South Korea
[3] Catholic Univ Korea, Yeouido St Marys Hosp, Dept Orthodont, Suwon 442723, South Korea
[4] Kyung Hee Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[5] Ajou Univ, Sch Clin Dental Sci, Dept Orthodont, Suwon 441749, South Korea
[6] Univ Calif San Francisco, Dept Orofacial Sci, San Francisco, CA 94143 USA
关键词
Osseointegration; Mini-implant; Finite element analysis; Von-Mises stress; CORTICAL BONE; ANCHORAGE; MICROIMPLANT; UPDATE;
D O I
10.4041/kjod.2011.41.6.423
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEN. Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling. (Korean J Orthod 2011;41(6): 423-430)
引用
收藏
页码:423 / 430
页数:8
相关论文
共 33 条
[1]   BONDED ARCH BARS IN ORAL AND MAXILLOFACIAL SURGERY - AN UPDATE [J].
BAURMASH, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1993, 76 (05) :553-556
[2]  
Byloff F K, 2000, Int J Adult Orthodon Orthognath Surg, V15, P129
[3]   Treatment of skeletal Class II adult patient with vertical and transverse problems caused by nasal airway obstruction using microimplant anchorage [J].
Chae, Jong-Moon ;
Chang, Na-Young ;
Cho, Jin-Hyoung ;
Kang, Kyung-Hwa ;
Kim, Sang-Cheol .
KOREAN JOURNAL OF ORTHODONTICS, 2009, 39 (04) :257-272
[4]   Atypical orthodontic extraction pattern managed by differential en-masse retraction against a temporary skeletal anchorage device in the treatment of bimaxillary protrusion [J].
Chung, Kyu-Rhim ;
Choo, HyeRan ;
Lee, Jin-Hwa ;
Kim, Seong-Hun .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :423-432
[5]  
Costa A, 1998, Int J Adult Orthodon Orthognath Surg, V13, P201
[6]  
Creekmore T D, 1983, J Clin Orthod, V17, P266
[7]   The use of small titanium screws for orthodontic anchorage [J].
Deguchi, T ;
Takano-Yamamoto, T ;
Kanomi, R ;
Hartsfield, JK ;
Roberts, WE ;
Garetto, LP .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) :377-381
[8]   Implant-Bone Interface Stress Distribution in Immediately Loaded Implants of Different Diameters: A Three-Dimensional Finite Element Analysis [J].
Ding, Xi ;
Zhu, Xing-Hao ;
Liao, Sheng-Hui ;
Zhang, Xiu-Hua ;
Chen, Hong .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05) :393-402
[9]   Effect of Diameter and Length on Stress Distribution of the Alveolar Crest around Immediate Loading Implants [J].
Ding, Xi ;
Liao, Sheng-Hui ;
Zhu, Xing-Hao ;
Zhang, Xiu-Hua ;
Zhang, Lin .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) :279-287
[10]   Bone's mechanostat: A 2003 update [J].
Frost, HM .