New generation Amberlite XAD resin for the removal of metal ions: A review

被引:82
作者
Ahmad, Akil [1 ]
Siddique, Jamal Akhter [2 ]
Laskar, Mohammad Asaduddin [3 ]
Kumar, Rajeev [4 ]
Mohd-Setapar, Siti Hamidah [1 ]
Khatoon, Asma [1 ]
Shiekh, Rayees Ahmad [5 ]
机构
[1] Univ Teknol Malaysia, Fac Chem Engn, CLEAR, Utm Johor Bahru 81310, Johor, Malaysia
[2] Czech Tech Univ, Fac Civil Engn, Dept Mat Engn & Chem, Prague 716629, Thakurova, Czech Republic
[3] Jazan Univ, Dept Chem, Jazan, Saudi Arabia
[4] King Abdulaziz Univ, Fac Meteorol Environm & Arid Land Agr, Dept Environm Sci, Jeddah 21589, Saudi Arabia
[5] Taibah Univ, Fac Sci, Dept Chem, Al Madinah Al Munawarrah, Saudi Arabia
来源
JOURNAL OF ENVIRONMENTAL SCIENCES | 2015年 / 31卷
关键词
Amberlite XAD; Toxic metals; Chelating resin; Preconcentration; Sorption capacity; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; ONLINE PRECONCENTRATION SYSTEM; PLASMA-MASS SPECTROMETRY; RARE-EARTH-ELEMENTS; TRACE HEAVY-METALS; ENVIRONMENTAL-SAMPLES; WATER SAMPLES; SPECTROPHOTOMETRIC DETERMINATION; FUNCTIONALIZED RESIN;
D O I
10.1016/j.jes.2014.12.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The direct determination of toxic metal ions, in environmental samples, is difficult because of the latter's presence in trace concentration in association with complex matrices, thereby leading to insufficient sensitivity and selectivity of the methods used. The simultaneous removal of the matrix and preconcentration of the metal ions, through solid phase extraction, serves as the promising solution. The mechanism involved in solid phase extraction (SPE) depends on the nature of the sorbent and analyte. Thus, SPE is carried out by means of adsorption, ion exchange, chelation, ion pair formation, and so forth. As polymeric supports, the commercially available Amberlite resins have been found very promising for designing chelating matrices due to its good physical and chemical properties such as porosity, high surface area, durability and purity. This review presents an overview of the various works done on the modification of Amberlite XAD resins with the objective of making it an efficient sorbent. The methods of modifications which are generally based on simple impregnation, sorption as chelates and chemical bonding have been discussed. The reported results, including the preconcentration limit, the detection limit, sorption capacity, preconcentration factors etc., have been reproduced. (C) 2015 The Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V.
引用
收藏
页码:104 / 123
页数:20
相关论文
共 162 条
[21]   The use of Bacillus subtilis immobilized on Amberlite XAD-4 as a new biosorbent in trace metal determination [J].
Dogru, Mehmet ;
Gul-Guven, Reyhan ;
Erdogan, Sait .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (01) :166-173
[22]   Preconcentration of manganese(II) from natural and sea water on a palmitoyl quinolin-8-ol functionalized XAD copolymer resin and spectrophotometric determination with the formaldoxime reagent [J].
Dogutan, M ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2003, 485 (02) :205-212
[23]   Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with 0,0-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4 [J].
dos Santos, EJ ;
Herrmann, AB ;
Ribeiro, AS ;
Curtius, AJ .
TALANTA, 2005, 65 (02) :593-597
[24]   Simultaneous preconcentration of Co(II), Ni(II), Cu(II), and Cd(II) from environmental samples on Amberlite XAD-2000 column and determination by FAAS [J].
Duran, Celal ;
Senturk, Hasan Basri ;
Elci, Latif ;
Soylak, Mustafa ;
Tufekci, Mehmet .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 162 (01) :292-299
[25]   Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS) [J].
Duran, Celal ;
Gundogdu, Ali ;
Bulut, Volkan Numan ;
Soylak, Mustafa ;
Elci, Latif ;
Senturk, Hasan Basri ;
Tufekci, Mehmet .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 146 (1-2) :347-355
[26]   Determination of some trace metals in environmental samples by flame AAS following solid phase extraction with amberlite XAD-2000 resin after complexing with 8-hydroxyquinoline [J].
Duran, Celal ;
Senturk, H. Basri ;
Gundogdu, Ali ;
Bulut, V. Numan ;
Elci, Latif ;
Soylak, Mustafa ;
Tufekci, Mehmet ;
Uygur, Yaprak .
CHINESE JOURNAL OF CHEMISTRY, 2007, 25 (02) :196-202
[27]   Extraction chromatography of thorium ion by solid phase impregnated resins containing bi-functional organic extractants [J].
El-Dessouky, S. I. ;
Borai, E. H. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 268 (02) :247-254
[28]   Removal of lanthanum and gadolinium from nitrate medium using Aliquat-336 impregnated onto Amberlite XAD-4 [J].
El-Sofany, E. A. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 153 (03) :948-954
[29]   Determination of trace impurities in some nickel compounds by flame atomic absorption spectrometry after solid phase extraction using Amberlite XAD-16 resin [J].
Elçi, L ;
Soylak, M ;
Uzun, A ;
Büyükpatir, E ;
Dogan, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :358-361
[30]   Solid phase extraction method for the determination of iron, lead and chromium by atomic absorption spectrometry using Amberite XAD-2000 column in various water samples [J].
Elci, Latif ;
Kartal, Aslihan A. ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 153 (1-2) :454-461