Energy saving effect prediction and post evaluation of air-conditioning system in public buildings

被引:29
作者
Chang, Chenchen [1 ]
Zhao, Jing [1 ]
Zhu, Neng [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China
关键词
Artificial Neural Network; Refrigeration Operation Energy Efficiency Ratio; Prediction evaluation; Post evaluation; Energy saving effect; Retrofit air-conditioning system; ARTIFICIAL NEURAL-NETWORKS; CONSUMPTION;
D O I
10.1016/j.enbuild.2011.08.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate energy saving effect evaluation analysis of building energy efficiency retrofit is of benefit to obtain technology optimization and fast return of investment. According to the implement sequence, evaluation methods can be divided into post evaluation and prediction evaluation. The energy saving effect of an air-conditioning system retrofit project was analyzed by these two models respectively. The post evaluation model was built based on the spot test data and a parameter called as Refrigeration Operation Energy saving Effect Ratio (ROEER). The prediction evaluation model was built based on Back-Propagation Artificial Neural Network by the use of MATLAB Neural Network Toolbox. The comparison result between these two kinds of evaluation models match well with each other. These two models can be used to predict and evaluate energy saving effect of air-conditioning system retrofit to further improve the real energy saving effect of building energy efficiency retrofit. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3243 / 3249
页数:7
相关论文
共 19 条
[1]   The retrofit of industrial air-conditioning system on energy efficiency and emission reduction [J].
Ding, Yan ;
Tian, Zhe ;
Zhu, Neng .
ENERGY AND BUILDINGS, 2010, 42 (06) :955-958
[2]   Part load operation coefficient of air-conditioning system of public building [J].
Ding, Yong ;
Li, Baizhan ;
Yao, Runming ;
Tan, Ying .
ENERGY AND BUILDINGS, 2010, 42 (10) :1902-1907
[3]   Application of an energy management and control system to assess the potential of different control strategies in HVAC systems [J].
Escriva-Escriva, Guillermo ;
Segura-Heras, Isidoro ;
Alcazar-Ortega, Manuel .
ENERGY AND BUILDINGS, 2010, 42 (11) :2258-2267
[4]  
*GB, 2005, GB503652005
[5]   Prediction of hourly energy consumption in buildings based on a feedback artificial neural network [J].
González, PA ;
Zamarreño, JA .
ENERGY AND BUILDINGS, 2005, 37 (06) :595-601
[6]   Using artificial neural network models in stock market index prediction [J].
Guresen, Erkam ;
Kayakutlu, Gulgun ;
Daim, Tugrul U. .
EXPERT SYSTEMS WITH APPLICATIONS, 2011, 38 (08) :10389-10397
[7]   Comparison between detailed model simulation and artificial neural network for forecasting building energy consumption [J].
Hernandez Neto, Alberto ;
Sanzovo Fiorelli, Flavio Augusto .
ENERGY AND BUILDINGS, 2008, 40 (12) :2169-2176
[8]   An evaluation of Bayesian techniques for controlling model complexity and selecting inputs in a neural network for short-term load forecasting [J].
Hippert, Henrique S. ;
Taylor, James W. .
NEURAL NETWORKS, 2010, 23 (03) :386-395
[9]  
HU X, 1999, HV AC, V29, P1
[10]   Applications of artificial neural networks in energy systems - A review [J].
Kalogirou, SA .