Preliminary experience with Impella Recover® LP5.0 in nine patients with cardiogenic shock: A new circulatory support system in the intensive cardiac care unit

被引:11
作者
Bresson, Didier [1 ]
Sibellas, Franck [1 ]
Farhat, Fadi
Jegaden, Olivier
Kirkorian, Gilbert [1 ]
Bonnefoy, Eric [1 ]
机构
[1] Hosp Civils Lyon, Intens Cardiac Care Unit, Lyon, France
关键词
Acute myocardial infarction; Cardiogenic shock; Left ventricular assist device; Axial pump; VENTRICULAR ASSIST DEVICE; HEART-FAILURE; PROVIDES; SAFETY;
D O I
10.1016/j.acvd.2011.04.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim. - Cardiogenic shock is associated with high mortality. We report our experience with the short-term left ventricular axial pump Impella LP5.0 in nine patients with severe ischaemic heart failure. Methods. - Six patients (group 1) presented with cardiogenic shock at the acute phase of an ST elevation myocardial infarction. Three patients (group 2) had severe ischaemic cardiomyopathy with temporary contra-indication to LVAD or transplantation. We measured haemodynamic and metabolic variables up to 96 hours and recorded morbidity, mechanical pump failures, and mortality up to one year postimplantation. Results. - In all patients the Impella LP5.0 was safely placed through the right subclavian artery. Cardiac power output increased from 0.64 (0.07) W to 0.94 (0.44) W and 1.02 (0.30) W at 24 and 72 hours, respectively. The Impella LP5.0 remained in place for 12 (7.2) days. In group 1, five patients were in INTERMACS Profile 3 at the time of pump insertion. Three could be weaned and survived. One patient in INTERMACS Profile 1 died of intractable heart failure within hours. In group 2, two of three patients underwent heart transplantation. Haemorrhage requiring transfusions was observed in four patients but only one case was directly related to the Impella LP5.0. Conclusion. - Left ventricular assistance with the Impella LP5.0 appears to be well tolerated. It may be especially useful in patients with acute myocardial infarction complicated by cardiogenic shock who achieve INTERMACS Profile 3 with initial treatment. (C) 2011 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:458 / 464
页数:7
相关论文
共 22 条
  • [1] Task force 1: The ACCF and AHA codes of conduct in human subjects research
    Adams, RJ
    Antman, EM
    Kavey, REW
    [J]. CIRCULATION, 2004, 110 (16) : 2512 - 2516
  • [2] Left ventricular assist device and drug therapy for the reversal of heart failure
    Birks, Emma J.
    Tansley, Patrick D.
    Hardy, James
    George, Robert S.
    Bowles, Christopher T.
    Burke, Margaret
    Banner, Nicholas R.
    Khaghani, Asghar
    Yacoub, Magdi H.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) : 1873 - 1884
  • [3] A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock
    Burkhoff, Daniel
    Cohen, Howard
    Brunckhorst, Corinna
    O'Neill, William W.
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (03) : 469.e1 - 469.e8
  • [4] Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials
    Cheng, Jin M.
    den Uil, Corstiaan A.
    Hoeks, Sanne E.
    van der Ent, Martin
    Jewbali, Lucia S. D.
    van Domburg, Ron T.
    Serruys, Patrick W.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (17) : 2102 - 2108
  • [5] Percutaneous Mechanical Assistance for the Failing Heart
    De Souza, Cristiano Freitas
    Brito, Flavio De Souza
    De Lima, Valter Correia
    De Camargo Carvalho, Antonio Carlos
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2010, 23 (02) : 195 - 202
  • [6] ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008
    Dickstein, Kenneth
    Cohen-Solal, Alain
    Filippatos, Gerasimos
    McMurray, John J. V.
    Ponikowski, Piotr
    Poole-Wilson, Philip Alexander
    Stromberg, Anna
    van Veldhuisen, Dirk J.
    Atar, Dan
    Hoes, Arno W.
    Keren, Andre
    Mebazaa, Alexandre
    Nieminen, Markku
    Priori, Silvia Giuliana
    Swedberg, Karl
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (19) : 2388 - 2442
  • [7] Experience with the Impella® recovery axial-flow system for acute heart failure at three cardiothoracic centers in Sweden
    Granfeldt, Hans
    Hellgren, Laila
    Dellgren, Goran
    Myrdal, Gunnar
    Wassberg, Erik
    Kjellman, Ulf
    Ahn, Henrik
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2009, 43 (04) : 233 - 239
  • [8] Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5
    Henriques, JPS
    Remmelink, M
    Baan, J
    van der Schaaf, RJ
    Vis, MM
    Koch, KT
    Scholten, EW
    de Mol, BAJM
    Tijssen, JGP
    Piek, JJ
    de Winter, RJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (07) : 990 - 992
  • [9] KANTROWITZ ADRIAN, 1967, PROGR CARDIOV DIS, V10, P134, DOI 10.1016/0033-0620(67)90005-9
  • [10] Organ perfusion with hemopump device assistance with and without intraaortic balloon pumping
    Meyns, B
    Nishimura, Y
    Racz, R
    Jashari, R
    Flameng, W
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (02) : 243 - 253