Evaluation of Parallel Level Sets and Bowsher's Method as Segmentation- Free Anatomical Priors for Time-of-Flight PET Reconstruction

被引:34
作者
Schramm, Georg [1 ]
Holler, Martin [2 ]
Rezaei, Ahmadreza [1 ]
Vunckx, Kathleen [1 ]
Knoll, Florian [3 ]
Bredies, Kristian [2 ]
Boada, Fernando [3 ]
Nuyts, Johan [1 ]
机构
[1] KU UZ Leuven, Dept Imaging & Pathol, Div Nucl Med, B-3000 Leuven, Belgium
[2] Karl Franzens Univ Graz, Inst Math & Sci Comp, A-8010 Graz, Austria
[3] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, New York, NY 10016 USA
关键词
Image reconstruction; positron emission tomography (PET); anatomical priors; PARTIAL-VOLUME CORRECTION; POSITRON-EMISSION-TOMOGRAPHY; IMAGE-RECONSTRUCTION; BRAIN; DISTRIBUTIONS; PERFORMANCE; ALGORITHMS;
D O I
10.1109/TMI.2017.2767940
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this article, we evaluate Parallel Level Sets (PLS) and Bowsher's method as segmentation-free anatomical priors for regularized brain positron emission tomography (PET) reconstruction. We derive the proximity operators for two PLS priors and use the EM-TV algorithm in combination with the first order primal-dual algorithm by Chambolle and Pock to solve the non-smooth optimization problem for PET reconstruction with PLS regularization. In addition, we compare the performance of two PLS versions against the symmetric and asymmetric Bowsher priors with quadratic and relative difference penalty function. For this aim, we first evaluate reconstructions of 30 noise realizations of simulated PET data derived from a real hybrid positron emission tomography/magnetic resonance imaging (PET/MR) acquisition in terms of regional bias and noise. Second, we evaluate reconstructions of a real brain PET/MR data set acquired on a GE Signa time-of-flight PET/MR in a similar way. The reconstructions of simulated and real 3D PET/MR data show that all priors were superior to post-smoothed maximum likelihood expectation maximization with ordered subsets (OSEM) in terms of bias-noise characteristics in different regions of interest where the PET uptake follows anatomical boundaries. Our implementation of the asymmetric Bowsher prior showed slightly superior performance compared with the two versions of PLS and the symmetric Bowsher prior. At very high regularization weights, all investigated anatomical priors suffer from the transfer of non-shared gradients.
引用
收藏
页码:590 / 603
页数:14
相关论文
共 39 条
  • [21] Model Fusion and Joint Inversion
    Haber, Eldad
    Gazit, Michal Holtzman
    [J]. SURVEYS IN GEOPHYSICS, 2013, 34 (05) : 675 - 695
  • [22] Three-dimensional maximum probability atlas of the human brain, with particular reference to the temporal lobe
    Hammers, A
    Allom, R
    Koepp, MJ
    Free, SL
    Myers, R
    Lemieux, L
    Mitchell, TN
    Brooks, DJ
    Duncan, JS
    [J]. HUMAN BRAIN MAPPING, 2003, 19 (04) : 224 - 247
  • [23] ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA
    HUDSON, HM
    LARKIN, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 601 - 609
  • [24] Physical and clinical performance of the mCT time-of-flight PET/CT scanner
    Jakoby, B. W.
    Bercier, Y.
    Conti, M.
    Casey, M. E.
    Bendriem, B.
    Townsend, D. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) : 2375 - 2389
  • [25] Inverse problems with structural prior information
    Kaipio, JP
    Kolehmainen, V
    Vauhkonen, M
    Somersalo, E
    [J]. INVERSE PROBLEMS, 1999, 15 (03) : 713 - 729
  • [26] A novel technique to incorporate structural prior information into multi-modal tomographic reconstruction
    Kazantsev, Daniil
    Ourselin, Sebastien
    Hutton, Brian F.
    Dobson, Katherine J.
    Kaestner, Anders P.
    Lionheart, William R. B.
    Withers, Philip J.
    Lee, Peter D.
    Arridge, Simon R.
    [J]. INVERSE PROBLEMS, 2014, 30 (06)
  • [27] Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer
    Knoll, Florian
    Holler, Martin
    Koesters, Thomas
    Otazo, Ricardo
    Bredies, Kristian
    Sodickson, Daniel K.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) : 1 - 16
  • [28] Expectation maximization reconstruction of positron emission tomography images using anatomical magnetic resonance information
    Lipinski, B
    Herzog, H
    Kops, ER
    Oberschelp, W
    MullerGartner, HW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 129 - 136
  • [29] Meltzer CC, 1999, J NUCL MED, V40, P2053
  • [30] MEASUREMENT OF RADIOTRACER CONCENTRATION IN BRAIN GRAY-MATTER USING POSITRON EMISSION TOMOGRAPHY - MRI-BASED CORRECTION FOR PARTIAL VOLUME EFFECTS
    MULLERGARTNER, HW
    LINKS, JM
    PRINCE, JL
    BRYAN, RN
    MCVEIGH, E
    LEAL, JP
    DAVATZIKOS, C
    FROST, JJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04) : 571 - 583