Photobleaching in two-photon scanning fluorescence correlation spectroscopy

被引:28
作者
Petrasek, Zdenek [1 ]
Schwille, Petra [1 ]
机构
[1] Tech Univ Dresden, Biotechnol Zentrum, Biophys Grp, D-01307 Dresden, Germany
关键词
diffusion; fluorescence; fluorescence correlation spectroscopy; photobleaching; photochemistry;
D O I
10.1002/cphc.200700579
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Two-photon excitation in fluorescence correlation spectroscopy (FCS) is often preferred to one-photon excitation because of reduced bulk photobleaching and photodamage, and deeper penetration into scattering media, such as thick biological specimens. Two-photon FCS, however, suffers from lower signal-to-noise I ratios which are directly related to the lower molecular brightness achieved. We compare standard FCS with a fixed measurement volume with scanning FCS, where the measurement volume is scanned along a circular path. The experimental results show that photobleaching is the dominant cause of the effects observed at the high excitation powers necessary for good signal-to-noise ratios. Theoretical calculations assuming a non-uniform excitation intensity profile, and using the concept of generalized volume contrast, provide an explanation for the photo-bleaching effects commonly observed in two-photon FCS at high excitation intensities, without having to assume optical saturation. Scanning alleviates these effects by spreading the photobleaching dose over a larger area, thereby reducing the depletion of fluorescent molecules in the measurement volume. These results, which facilitate understanding of the photobleaching in FCS and of the positive effects of scanning, are particularly important in studies involving the autocorrelation amplitude g(0), such as concentration measurements or binding studies using fluorescence cross-correlation between two labeled species.
引用
收藏
页码:147 / 158
页数:12
相关论文
共 53 条
[1]  
Amediek A, 2002, SINGLE MOL, V3, P201, DOI 10.1002/1438-5171(200208)3:4<201::AID-SIMO201>3.0.CO
[2]  
2-7
[3]   A dynamic view of cellular processes by in vivo fluorescence auto- and cross-correlation spectroscopy [J].
Bacia, K ;
Schwille, P .
METHODS, 2003, 29 (01) :74-85
[4]   Excitation saturation in two-photon fluorescence correlation spectroscopy [J].
Berland, K ;
Shen, GQ .
APPLIED OPTICS, 2003, 42 (27) :5566-5576
[5]   Scanning two-photon fluctuation correlation spectroscopy: Particle counting measurements for detection of molecular aggregation [J].
Berland, KM ;
So, PTC ;
Chen, Y ;
Mantulin, WW ;
Gratton, E .
BIOPHYSICAL JOURNAL, 1996, 71 (01) :410-420
[6]   2-PHOTON FLUORESCENCE CORRELATION SPECTROSCOPY - METHOD AND APPLICATION TO THE INTRACELLULAR ENVIRONMENT [J].
BERLAND, KM ;
SO, PTC ;
GRATTON, E .
BIOPHYSICAL JOURNAL, 1995, 68 (02) :694-701
[7]   Photobleaching, mobility, and compartmentalisation: Inferences in fluorescence correlation spectroscopy [J].
Delon, A ;
Usson, Y ;
Derouard, J ;
Biben, T ;
Souchier, C .
JOURNAL OF FLUORESCENCE, 2004, 14 (03) :255-267
[8]   Measuring fast dynamics in solutions and cells with a laser scanning microscope [J].
Digman, MA ;
Brown, CM ;
Sengupta, P ;
Wiseman, PW ;
Horwitz, AR ;
Gratton, E .
BIOPHYSICAL JOURNAL, 2005, 89 (02) :1317-1327
[9]   Spatial two-photon fluorescence cross-correlation Spectroscopy for controlling molecular transport in microfluidic structures [J].
Dittrich, PS ;
Schwille, P .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4472-4479
[10]  
Dittrich PS, 2001, APPL PHYS B-LASERS O, V73, P829, DOI 10.1007/sO03400100737