Investigation into a suitable scintillator and coded-aperture material for a mixed-field radiation imaging system

被引:3
作者
Cieslak, M. J. [1 ]
Gamage, K. A. A. [2 ]
Glover, R. [3 ]
机构
[1] Univ Lancaster, Dept Engn, Lancaster LA1 4YW, England
[2] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
[3] Sellafield Ltd, Radiometr Syst Grp, Seascale CA20 1PG, England
来源
JOURNAL OF INSTRUMENTATION | 2017年 / 12卷
基金
英国工程与自然科学研究理事会;
关键词
Instrumentation for neutron sources; Neutron detectors (cold; thermal; fast neutrons); Radiation monitoring; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); PULSE-SHAPE DISCRIMINATION; PLASTIC SCINTILLATORS; NEUTRON DETECTION; GAMMA; ENVIRONMENT; DETECTOR; ARRAYS; CF-252;
D O I
10.1088/1748-0221/12/12/P12007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monte-Carlo modelling (MCNPX) methods have been employed to conduct an investigation into a suitable scintillator and coded-aperture material for a scintillator based mixed-field radiation imaging system. Single stilbene crystal, pure and Li-6-loaded plastic scintillators were simulated and their neutron/gamma detection performance compared when exposed to the spontaneous fission spectrum produced by Cf-252. The most suitable candidate was then incorporated into a scintillator based mixed-field coded-aperture imaging system. Coded-aperture models made of three W and Cd-113 compositions were tested in different neutron/gamma environments with a square W collimator modelled around the aperture. Each simulation involved recording the interactions of neutron events in organic solid scintillator, whose neutron/gamma detection performance was assessed prior to the coded-aperture material investigation. Three coded-aperture material compositions have been tested with the simulated Cf-252 spontaneous fission as well as (AmBe)-Am-241 neutron sources. Results generally claim very good detection sensitivity and spatial resolution for the radioactive sources located in the centre of the aperture.
引用
收藏
页数:16
相关论文
共 38 条
  • [1] Near-field artifact reduction in planar coded aperture imaging
    Accorsi, R
    Lanza, RC
    [J]. APPLIED OPTICS, 2001, 40 (26) : 4697 - 4705
  • [2] Comparative analysis of pulse shape discrimination methods in a 6Li loaded plastic scintillator
    Balmer, Matthew J. I.
    Gamage, Kelum A. A.
    Taylor, Graeme C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 788 : 146 - 153
  • [3] Beaumont J., 2013, 2013 3 INT C ADV NUC, P1
  • [4] Imaging of fast neutrons and gamma rays from 252Cf in a heavily shielded environment
    Beaumont, Jonathan S.
    Shippen, B. Alan
    Mellor, Matthew P.
    Joyce, Malcolm J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 847 : 77 - 85
  • [5] Neutron detection in a high-gamma field using solution-grown stilbene
    Bourne, M. M.
    Clarke, S. D.
    Adamowicz, N.
    Pozzi, S. A.
    Zaitseva, N.
    Carman, L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 348 - 355
  • [6] A SCINTILLATION COUNTER WITH NEUTRON AND GAMMA-RAY DISCRIMINATORS
    BROOKS, FD
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1959, 4 (03): : 151 - 163
  • [7] Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection
    Cherepy, Nerine J.
    Sanner, Robert D.
    Beck, Patrick R.
    Swanberg, Erik L.
    Tillotson, Thomas M.
    Payne, Stephen A.
    Hurlbut, Charles R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 778 : 126 - 132
  • [8] Pulse shape discrimination characteristics of stilbene crystal, pure and 6Li loaded plastic scintillators for a high resolution coded-aperture neutron imager
    Cieslak, M. J.
    Gamage, K. A. A.
    Glover, R.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Coded-aperture imaging systems: Past, present and future development - A review
    Cieslak, Michal J.
    Gamage, Kelum A. A.
    Glover, Robert
    [J]. RADIATION MEASUREMENTS, 2016, 92 : 59 - 71
  • [10] An X-ray imager based on silicon microstrip detector and coded mask
    Del Monte, E.
    Costa, E.
    Di Persio, G.
    Donnarumma, I.
    Evangelista, Y.
    Feroci, M.
    Frutti, M.
    Lapshov, I.
    Lazzarotto, F.
    Mastropietro, M.
    Morelli, E.
    Pacciani, L.
    Porrovecchio, G.
    Rapisarda, M.
    Rubini, A.
    Soffitta, P.
    Tavani, M.
    Argan, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) : 191 - 193