Integrated pre-concentrator gas sensor microsystem for ppb level benzene detection

被引:65
作者
Leidinger, Martin [1 ]
Rieger, Max [2 ]
Sauerwald, Tilman [1 ]
Alepee, Christine [3 ]
Schuetze, Andreas [1 ]
机构
[1] Univ Saarland, Lab Measurement Technol, D-66123 Saarbrucken, Germany
[2] Fraunhofer Inst Chem Technol ICT, D-76327 Pfinztal, Germany
[3] SGX Sensortech SA, CH-2035 Corcelles Cormondreche, Switzerland
关键词
Gas pre concentration; Metal-organic frameworks; Integrated gas sensor system; Metal oxide semiconductor gas sensor; Indoor air quality; FEM simulation; VOLATILE ORGANIC-COMPOUNDS; INDOOR AIR-QUALITY; FRAMEWORKS;
D O I
10.1016/j.snb.2016.04.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An integrated microsystem for (indoor) air quality monitoring applications is presented. By combining a gas pre-concentrator based on metal-organic frameworks (MOFs) and a metal oxide semiconductor gas sensor, a device for detecting ppb levels of volatile organic compounds was designed, integrated and tested with benzene as a target gas. Two metal organic frameworks have been characterized for their suitability as gas pre-concentration materials for benzene and toluene using inverse gas chromatography and mass spectrometry measurements in order to obtain breakthrough values for gas adsorption. Both MOFs showed a higher pre-concentration effect compared to Tenax (R) TA, a state-of-the-art commercial adsorbent material. By depositing a MOF material on a micro hotplate integrated in a package together with a gas sensor, an integrated gas sensor microsystem was realized. This system has been characterized in FEM simulations concerning its gas pre-concentration capabilities and behavior. Test measurements were performed using benzene at concentrations of 101000 ppb. Both the simulations and the measurements show the suitability of the system design for the task. Significantly increased gas concentrations have been observed during thermal desorption from the pre-concentrator after gas adsorption at a low temperature. ((c)) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:988 / 996
页数:9
相关论文
共 26 条
[1]   Discriminative detection of nitro aromatic explosives by a luminescent metal-organic framework [J].
Asha, K. S. ;
Bhattacharyya, Kalishankar ;
Mandal, Sukhendu .
JOURNAL OF MATERIALS CHEMISTRY C, 2014, 2 (47) :10073-10081
[2]   The health effects of nonindustrial indoor air pollution [J].
Bernstein, Jonathan A. ;
Alexis, Neil ;
Bacchus, Hyacinth ;
Bernstein, I. Leonard ;
Fritz, Pat ;
Horner, Elliot ;
Li, Ning ;
Mason, Stephany ;
Nel, Andre ;
Oullette, John ;
Reijula, Kari ;
Reponen, Tina ;
Seltzer, James ;
Smith, Alisa ;
Tarlo, Susan M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :585-591
[3]   Sick building syndrome [J].
Burge, PS .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2004, 61 (02) :185-190
[4]   A chemically functionalizable nanoporous material [Cu3(TMA)2(H2O)3]n [J].
Chui, SSY ;
Lo, SMF ;
Charmant, JPH ;
Orpen, AG ;
Williams, ID .
SCIENCE, 1999, 283 (5405) :1148-1150
[5]  
Conder J.R., 1979, PHYSICOCHEMICAL MEAS
[6]   The AIRMEX study - VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data [J].
Geiss, Otmar ;
Giannopoulos, Georgios ;
Tirendi, Salvatore ;
Barrero-Moreno, Josefa ;
Larsen, Bo R. ;
Kotzias, Dimitrios .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (22) :3676-3684
[7]   Computational screening of metal-organic frameworks for large-molecule chemical sensing [J].
Greathouse, Jeffery A. ;
Ockwig, Nathan W. ;
Criscenti, Louise J. ;
Guilinger, T. R. ;
Pohl, Phil ;
Allendorf, Mark D. .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (39) :12621-12629
[8]   Risk assessment of exposure to volatile organic compounds in different indoor environments [J].
Guo, H ;
Lee, SC ;
Chan, LY ;
Li, WM .
ENVIRONMENTAL RESEARCH, 2004, 94 (01) :57-66
[9]   Gas mixing apparatus for automated gas sensor characterization [J].
Helwig, Nikolai ;
Schueler, Marco ;
Bur, Christian ;
Schuetze, Andreas ;
Sauerwald, Tilman .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (05)
[10]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564