Performance of the Fecal Immunochemical Test for Colorectal Cancer Screening Using Different Stool-Collection Devices: Preliminary Results from a Randomized Controlled Trial

被引:4
作者
Shin, Hye Young [1 ]
Suh, Mina [1 ]
Baik, Hyung Won [1 ,2 ]
Choi, Kui Son [1 ]
Park, Boyoung [1 ]
Jun, Jae Kwan [1 ]
Hwang, Sang-Hyun [3 ]
Kim, Byung Chang [4 ]
Lee, Chan Wha [5 ]
Oh, Jae Hwan [4 ]
Lee, You Kyoung [6 ]
Han, Dong Soo [7 ]
Lee, Do-Hoon [3 ]
机构
[1] Natl Canc Ctr, Natl Canc Control Inst, 323 Ilsan Ro, Goyang 10408, South Korea
[2] Yonsei Univ Hlth Syst, Severance Hosp, Lung Canc Clin, Seoul, South Korea
[3] Natl Canc Ctr Hosp, Dept Lab Med, Natl Canc Ctr, Ctr Diagnost Oncol, Goyang, South Korea
[4] Natl Canc Ctr Hosp, Ctr Colorectal Canc, Natl Canc Ctr, Goyang, South Korea
[5] Natl Canc Ctr Hosp, Ctr Canc Prevent & Detect, Natl Canc Ctr, Goyang, South Korea
[6] Soonchunhyang Univ, Dept Lab Med & Genet, Bucheon Hosp, Coll Med, Bucheon, South Korea
[7] Hanyang Univ, Dept Gastroenterol, Guri Hosp, Guri, South Korea
关键词
Colorectal neoplasms; Early detection of cancer; Screening; Intervention study; Predictive value of tests; OCCULT BLOOD-TEST; DIAGNOSTIC YIELD; TASK-FORCE; POPULATION; PROGRAM; INTERVENTION; COLONOSCOPY; HEMOGLOBIN; STRATEGIES; INCREASES;
D O I
10.5009/gnl15479
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: We are in the process of conducting a randomized trial to determine whether compliance with the fecal immunochemical test (FIT) for colorectal cancer screening differs according to the stool-collection method. This study was an interim analysis of the performance of two stool-collection devices (sampling bottle vs conventional container). Methods: In total, 1,701 individuals (age range, 50 to 74 years) were randomized into the sampling bottle group (intervention arm) or the conventional container group (control arm). In both groups, we evaluated the FIT positivity rate, the positive predictive value for advanced neoplasia, and the detection rate for advanced neoplasia. Results: The FIT positivity rates were 4.1% for the sampling bottles and 2.0% for the conventional containers; these values were significantly different. The positive predictive values for advanced neoplasia in the sampling bottles and conventional containers were 11.1% (95% confidence interval [CI], -3.4 to 25.6) and 12.0% (95% CI, -0.7 to 24.7), respectively. The detection rates for advanced neoplasia in the sampling bottles and conventional containers were 4.5 per 1,000 persons (95% CI, 2.0 to 11.0) and 2.4 per 1,000 persons (95% CI, 0.0 to 5;0), respectively. Conclusions: The impact of these findings on FIT screening performance was unclear in this interim analysis. This impact should therefore be evaluated in the final analysis following the final enrollment period.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 28 条
[1]   Screening for colorectal neoplasms with new fecal occult blood tests: update on performance characteristics [J].
Allison, James E. ;
Sakoda, Lori C. ;
Levin, Theodore R. ;
Tucker, Jo P. ;
Tekawa, Irene S. ;
Cuff, Thomas ;
Pauly, Mary Pat ;
Shlager, Lyle ;
Palitz, Albert M. ;
Zhao, Wei K. ;
Schwartz, J. Sanford ;
Ransohoff, David F. ;
Selby, Joseph V. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2007, 99 (19) :1462-1470
[2]   Population Screening for Colorectal Cancer Means Getting FIT: The Past, Present, and Future of Colorectal Cancer Screening Using the Fecal Immunochemical Test for Hemoglobin (FIT) [J].
Allison, James E. ;
Fraser, Callum G. ;
Halloran, Stephen P. ;
Young, Graeme P. .
GUT AND LIVER, 2014, 8 (02) :117-130
[3]   Comparative Effectiveness of a Multifaceted Intervention to Improve Adherence to Annual Colorectal Cancer Screening in Community Health Centers A Randomized Clinical Trial [J].
Baker, David W. ;
Brown, Tiffany ;
Buchanan, David R. ;
Weil, Jordan ;
Balsley, Kate ;
Ranalli, Lauren ;
Lee, Ji Young ;
Cameron, Kenzie A. ;
Ferreira, M. Rosario ;
Stephens, Quinn ;
Goldman, Shira N. ;
Rademaker, Alred ;
Wolf, Michael S. .
JAMA INTERNAL MEDICINE, 2014, 174 (08) :1235-1241
[4]   Superior diagnostic performance of faecal immunochemical tests for haemoglobin in a head-to-head comparison with guaiac based faecal occult blood test among 2235 participants of screening colonoscopy [J].
Brenner, Hermann ;
Tao, Sha .
EUROPEAN JOURNAL OF CANCER, 2013, 49 (14) :3049-3054
[5]   Basic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood [J].
Castiglione, G ;
Grazzini, G ;
Miccinesi, G ;
Rubeca, T ;
Sani, C ;
Turco, P ;
Zappa, M .
JOURNAL OF MEDICAL SCREENING, 2002, 9 (03) :99-103
[6]   Immunochemical Fecal Occult Blood Testing Is Equally Sensitive for Proximal and Distal Advanced Neoplasia [J].
de Wijkerslooth, T. R. ;
Stoop, E. M. ;
Bossuyt, P. M. ;
Meijer, G. A. ;
van Ballegooijen, M. ;
van Roon, A. H. C. ;
Stegeman, I. ;
Kraaijenhagen, R. A. ;
Fockens, P. ;
van Leerdam, M. E. ;
Dekker, E. ;
Kuipers, E. J. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 (10) :1570-1578
[7]   Immunochemical faecal occult blood test: number of samples and positivity cutoff. What is the best strategy for colorectal cancer screening? [J].
Grazzini, G. ;
Visioli, C. B. ;
Zorzi, M. ;
Ciatto, S. ;
Banovich, F. ;
Bonanomi, A. G. ;
Bortoli, A. ;
Castiglione, G. ;
Cazzola, L. ;
Confortini, M. ;
Mantellini, P. ;
Rubeca, T. ;
Zappa, M. .
BRITISH JOURNAL OF CANCER, 2009, 100 (02) :259-265
[8]   An Automated Intervention With Stepped Increases in Support to Increase Uptake of Colorectal Cancer Screening A Randomized Trial [J].
Green, Beverly B. ;
Wang, Ching-Yun ;
Anderson, Melissa L. ;
Chubak, Jessica ;
Meenan, Richard T. ;
Vernon, Sally W. ;
Fuller, Sharon .
ANNALS OF INTERNAL MEDICINE, 2013, 158 (05) :301-311
[9]   Diagnostic yield of a one sample immunochemical test at different cut-off values in an organised screening programme for colorectal cancer [J].
Hamza, S. ;
Dancourt, V. ;
Lejeune, C. ;
Bidan, J. M. ;
Lepage, C. ;
Faivre, J. .
EUROPEAN JOURNAL OF CANCER, 2013, 49 (12) :2727-2733
[10]   Screening for colorectal cancer: randomised trial comparing guaiac-based and immunochemical faecal occult blood testing and flexible sigmoidoscopy [J].
Hol, L. ;
van Leerdam, M. E. ;
van Ballegooijen, M. ;
van Vuuren, A. J. ;
van Dekken, H. ;
Reijerink, J. C. I. Y. ;
van der Togt, A. C. M. ;
Habbema, J. D. F. ;
Kuipers, E. J. .
GUT, 2010, 59 (01) :62-68