Determination of silicon in biological samples by ICP-OES after non-oxidative decomposition under alkaline conditions

被引:40
作者
Hauptkorn, S [1 ]
Pavel, J [1 ]
Seltner, H [1 ]
机构
[1] Solvias AG, CH-4002 Basel, Switzerland
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 2-3期
关键词
D O I
10.1007/s002160100759
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-oxidative alkaline sample digestion procedure using tetramethylammonium hydroxide and a high pressure, microwave assisted autoclave digestion system was developed. The silicon concentrations of the digested samples were measured by inductively coupled axial plasma optical emission spectrometry (ICP-OES). Details of the digestion conditions as well as the optimised instrumental parameters for ICP-OES are described. The method was developed and tested using silicon-spiked ascorbic acid and applied to samples of animal tissue and organs. The total silicon content of two different reference materials, NIST 1577b Bovine liver and BCR 184 Bovine Muscle having neither certified nor informational values for Si was determined. The results obtained are compared with the results of independent methods such as wavelength dispersive x-ray fluorescence spectrometry (WDXRF) and solid sampling electrothermal atomic absorption spectrometry (ETAAS). The method described achieves a limit of detection of 2 mg kg(-1) using 100 mg of solid biological or organic material and covers a concentration range of up to 500 mg kg(-1).
引用
收藏
页码:246 / 250
页数:5
相关论文
共 20 条
[1]   Silicones and their determination in biological matrices - A review [J].
CavicVlasak, BA ;
Thompson, M ;
Smith, DC .
ANALYST, 1996, 121 (06) :R53-R63
[2]  
DHAESE PC, 1995, NEPHROL DIAL TRANSPL, V10, P1838
[3]   Determination of trimethylsilanol in the environment by LT-GC/ICP-OES and GC-MS [J].
Grumping, R ;
Mikolajczak, D ;
Hirner, AV .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02) :133-139
[4]   HPLC/ICP-OES determination of water-soluble silicone (PDMS) degradation products in leachates [J].
Grümping, R ;
Hirner, AV .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (04) :347-352
[5]  
GUZZI G, 1987, J RADIOANAL CHEM, V34, P35
[6]  
HOLDEN A J, 1992, Analytical Proceedings, V29, P260, DOI 10.1039/ap9922900260
[7]   Determination of silicon in biological tissue by electrothermal atomic absorption spectrometry using slurry sampling of original and pre-ashed samples [J].
Hornung, M ;
Krivan, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) :1123-1130
[8]  
HUANG M, COMMUNICATION
[9]   TISSUE COMPOSITION OF MAJOR AND TRACE-ELEMENTS IN UREMIA AND HYPERTENSION [J].
INDRAPRASIT, S ;
ALEXANDER, GV ;
GONICK, HC .
JOURNAL OF CHRONIC DISEASES, 1974, 27 (03) :135-161
[10]  
KRUSHEVSKA A, 1994, J ANAL ATOM SPECTROM, V9, P131