Operation of NIM5 fountain with 1.5x10-15 uncertainty and design of new NIM6 in NIM

被引:2
|
作者
Fang, F. [1 ]
Liu, N. [1 ]
Liu, K. [1 ]
Chen, W. [1 ]
Suo, R. [1 ]
Li, Tianchu [1 ]
机构
[1] Natl Inst Metrol, Div Time & Frequency, Beijing, Peoples R China
关键词
1ST ACCURACY EVALUATION; CLOCK;
D O I
10.1088/1742-6596/723/1/012009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The cesium fountain primary frequency standard NIM5 started to operate since 2008 and started to report to BIPM since 2014. The major constrains of NIM5 is a relatively large background signal at the detection and microwave leakages due to the Ramsey cavity. A new fountain clock NIM6 is under construction. Besides some improvements on the vacuum system, a new Ramsey cavity and a microwave synthesizer are made to reduce the Type B uncertainty. Another feature of NIM6 is collecting atoms from a MOT loading optical molasses to get more atoms with a more uniform density distribution. With a new frequency synthesizer based on cryogenic sapphire oscillator (CSO), NIM6 is aiming to reach the quantum projection noise, thus leading to a reduced Type A uncertainty compared with NIM5.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] The progress of the NIM6 fountain clock in NIM
    Fang, Fang
    Chen, Weiliang
    Liu, Kun
    Liu, Nianfeng
    Dai, Shaoyang
    Han, Lei
    Li, Tianchu
    2017 XXXIIND GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE (URSI GASS), 2017,
  • [2] The preliminary evaluation of the new fountain clock NIM6
    Fang, Fang
    Chen, Weiliang
    Liu, Kun
    Liu, Nianfeng
    Han, Lei
    Li, Tianchu
    2019 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (AP-RASC), 2019,
  • [3] Accuracy Evaluation of NIM5 Cesium Fountain Clock
    刘年丰
    房芳
    陈伟亮
    林平卫
    王平
    刘昆
    所睿
    李天初
    Chinese Physics Letters, 2013, 30 (01) : 45 - 48
  • [4] Accuracy Evaluation of NIM5 Cesium Fountain Clock
    Liu Nian-Feng
    Fang Fang
    Chen Wei-Liang
    Lin Ping-Wei
    Wang Ping
    Liu Kun
    Suo Rui
    Li Tian-Chu
    CHINESE PHYSICS LETTERS, 2013, 30 (01)
  • [6] NIM5 Cs fountain clock and its evaluation
    Fang, Fang
    Li, Mingshou
    Lin, Pingwei
    Chen, Weiliang
    Liu, Nianfeng
    Lin, Yige
    Wang, Ping
    Liu, Kun
    Suo, Rui
    Li, Tianchu
    METROLOGIA, 2015, 52 (04) : 454 - 468
  • [7] The transportable cesium fountain clock NIM5: its construction and performance
    Li, Tian-chu
    Lin, Ping-wei
    Li, Ming-shou
    Wang, Ping
    Chen, Wei-liang
    Liu, Nian-feng
    Lin, Yi-ge
    FRONTIERS OF PHYSICS IN CHINA, 2009, 4 (02): : 155 - 159
  • [8] The transportable cesium fountain clock NIM5: its construction and performance
    Tian-chu Li
    Ping-wei Lin
    Ming-shou Li
    Ping Wang
    Wei-liang Chen
    Nian-feng Liu
    Yi-ge Lin
    Frontiers of Physics in China, 2009, 4 : 155 - 159
  • [9] Accuracy Evaluations of the Cs Fountain Primary Frequency Standard NIM5
    Fang, Fang
    Chen, Weiliang
    Liu, Nianfeng
    Liu, Kun
    Suo, Rui
    Li, Tianchu
    2014 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2014, : 159 - 161
  • [10] THE TRANSPORTABLE CESIUM FOUNTAIN CLOCK NIM5: ITS CONSTRUCTION AND PERFORMANCE
    Li, Tianchu
    Lin, Pingwei
    Li, Mingshou
    Wang, Ping
    Chen, Weiliang
    Liu, Nianfeng
    Lin, Yige
    PROCEEDINGS OF THE 7TH SYMPOSIUM FREQUENCY STANDARDS AND METROLOGY, 2009, : 314 - 320