Imaging the aqueous humor outflow pathway in human eyes by three-dimensional micro-computed tomography (3D micro-CT)

被引:86
作者
Hann, Cheryl R. [1 ]
Bentley, Michael D. [2 ]
Vercnocke, Andrew [3 ]
Ritman, Erik L. [3 ]
Fautsch, Michael P. [1 ]
机构
[1] Mayo Clin, Dept Ophthalmol, Rochester, MN 55905 USA
[2] Minnesota State Univ, Dept Biol Sci, Mankato, MN USA
[3] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
3D micro-CT; three-dimensional micro-computed tomography; collector channels; outflow pathway; Schlemm's canal; intrascleral vasculature; anterior segment; OPEN-ANGLE GLAUCOMA; ARGON-LASER TRABECULOPLASTY; TRABECULAR MESHWORK; EXPERIMENTAL HYPERCHOLESTEROLEMIA; COLLECTOR CHANNELS; MICROCOMPUTED TOMOGRAPHY; NONGLAUCOMATOUS NORMALS; JUXTACANALICULAR TISSUE; PRIMARY DEGENERATION; TANGENTIAL SECTIONS;
D O I
10.1016/j.exer.2010.12.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 mu m or 5 gm voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 +/- 5 mu m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 +/- 13 mu m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 56 条
[1]   Extracellular matrix in the trabecular meshwork [J].
Acott, Ted S. ;
Kelley, Mary J. .
EXPERIMENTAL EYE RESEARCH, 2008, 86 (04) :543-561
[2]  
AINSWORTH JR, 1990, INVEST OPHTH VIS SCI, V31, P745
[3]   Schlemm's canal and primary open angle glaucoma: Correlation between Schlemm's canal dimensions and outflow facility [J].
Allingham, RR ;
deKater, AW ;
Ethier, CR .
EXPERIMENTAL EYE RESEARCH, 1996, 62 (01) :101-109
[4]   Gadolinium chelate coated gold nanoparticles as contrast agents for both X-ray computed tomography and magnetic resonance imaging [J].
Alric, Christophe ;
Taleb, Jacqueline ;
Le Duc, Geraldine ;
Mandon, Celine ;
Billotey, Claire ;
Le Meur-Herland, Alice ;
Brochard, Thierry ;
Vocanson, Francis ;
Janier, Marc ;
Perriat, Pascal ;
Roux, Stephane ;
Tillement, Olivier .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (18) :5908-5915
[5]  
ALVARADO J, 1984, OPHTHALMOLOGY, V91, P564
[6]  
ALVARADO JA, 1986, ARCH OPHTHALMOL-CHIC, V104, P1517
[8]   ANATOMICAL STUDY OF SCHLEMM CANAL AND AQUEOUS VEINS BY MEANS OF NEOPRENE CASTS .3. ARTERIAL RELATIONS OF SCHLEMM CANAL [J].
ASHTON, N ;
SMITH, R .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1953, 37 (10) :577-&
[10]   Reduction of the Available Area for Aqueous Humor Outflow and Increase in Meshwork Herniations into Collector Channels Following Acute IOP Elevation in Bovine Eyes [J].
Battista, Stephanie A. ;
Lu, Zhaozeng ;
Hofmann, Sara ;
Freddo, Thomas ;
Overby, Darryl R. ;
Gong, Haiyan .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (12) :5346-5352