EFFECTS OF THERMOCYCLING AND PH ON ULTRASTRUCTURES CHARACTERISTICS OF STAINLESS STEEL ARCHWIRES

被引:0
作者
Sheibaninia, Ahmad [1 ]
Ojani, Zahra [1 ]
Zarrabi, Fatemeh [1 ]
Rabbani, Marzeih [1 ]
Heydari, Niloufar [1 ]
机构
[1] Islamic Azad Univ, Dept Orthodont, Dent Sch, Tehran Branch, Tehran, Iran
关键词
surface roughness; stiffness; saliva PH; thermocycling; stainless steel wire; ORTHODONTIC ARCH WIRES; MECHANICAL-PROPERTIES; NICKEL RELEASE; BETA-TITANIUM; ION RELEASE; FLUORIDE;
D O I
10.17654/BS016020139
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Aim and Background. There are certain controversies about different changes in surface roughness and stiffness of stainless steel (SS) wires; also, the effects of thermocycling and saliva PH on the surface and mechanical properties of these orthodontics archwires. In the present study, the effects of thermocycling and saliva PH on the surface and mechanical properties of SS wires in Metallurgical Laboratory of Shiraz University during 2016-2017 were investigated. Method and materials. 5cm pieces of 0.016inch SS wires from Ormco Company were placed in a glassed-tube enclosed by borosilicate. The wires were randomly divided into groups 1, deepening in artificial saliva (PH 7.4), consisted of subgroups 1 and 2 and the second group with wires placed in the ascorbic acid contained artificial saliva (PH 4.5) consisted of subgroups 3 and 4 and each subgroup contained 10 pieces. 500 cycles of thermocycling in the 5 to 55 degrees C water were only applied to the subgroups 2 and 4. Surface and mechanical properties of SS wires were evaluated by Instron (Tensile Machine, Finland) and its roughness was measured by AFM machine. Finally, the data was analyzed using ANOVA. Results. A total of 40 samples in four groups based on different PH and presence/absence of thermocycling were evaluated. The most surface roughness was 0.15 +/- 0.02 mu m/Ra in PH 4.5 and presence of thermocycling. The lowest surface roughness was 0.06 +/- 0.009 mu m/Ra in PH 7.4 without thermocycling (P < 0.001). The maximum amount of stiffness was 24.6 +/- 1.4g/mm(2) in PH 7.4 without thermocycling and the lowest amount of it was 012.5 +/- 0.9g/mm(2) in PH 4.5 with the presence of thermocycling (P < 0.001). Conclusion. It seems that the lowest effects on the surface and mechanical properties of SS wires were induced in PH 7.4 without thermocycling.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 32 条
  • [1] Oral environment temperature changes induced by cold/hot liquid intake
    Airoldi, G
    Riva, G
    Vanelli, M
    Filippi, V
    Garattini, G
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (01) : 58 - 63
  • [2] [Anonymous], 1989, IARC MON EV CARC RIS, V49
  • [3] Phase transformation changes in thermocycled nickel-titanium orthodontic wires
    Berzins, David W.
    Roberts, Howard W.
    [J]. DENTAL MATERIALS, 2010, 26 (07) : 666 - 674
  • [4] BETA-TITANIUM - NEW ORTHODONTIC ALLOY
    BURSTONE, CJ
    GOLDBERG, AJ
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (02) : 121 - 132
  • [5] Drinking-water Chlorinated, 1991, IARC MONOGR EVAL CAR
  • [6] Salivary metal levels of orthodontic patients: a novel methodological and analytical approach
    Eliades, T
    Trapalis, C
    Eliades, G
    Katsavrias, E
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2003, 25 (01) : 103 - 106
  • [7] Nickel content of as-received, retrieved, and recycled stainless steel brackets
    Eliades, T
    Zinelis, S
    Eliades, G
    Athanasiou, AE
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (02) : 217 - 220
  • [8] Intraoral aging of the inner headgear component: A potential biocompatibility concern?
    Eliades, T
    Eliades, G
    Watts, DC
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (03) : 300 - 306
  • [9] Gopalan C., 2016, J INDIAN ORTHODONTIC, V50, P75