A randomised, controlled trial evaluating a low cost, 3D-printed bronchoscopy simulator

被引:44
作者
Pedersen, T. H. [1 ]
Gysin, J. [1 ]
Wegmann, A. [2 ]
Osswald, M. [1 ]
Ott, S. R. [3 ]
Theiler, L. [2 ]
Greif, R. [2 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Anaesthesia, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Resp Med, Bern, Switzerland
关键词
airway management; Anaesthesia; bronchoscopy; manikins; three-dimensional printing; BENCH MODEL FIDELITY; SKILLS;
D O I
10.1111/anae.13951
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Low-fidelity, simulation-based psychomotor skills training is a valuable first step in the educational approach to mastering complex procedural skills. We developed a cost-effective bronchial tree simulator based on a human thorax computed tomography scan using rapid-prototyping (3D-print) technology. This randomised, single-blind study evaluated how realistic our 3D-printed simulator would mimic human anatomy compared with commercially available bronchial tree simulators (Laerdal((R)) Airway Management Trainer with Bronchial Tree and AirSim Advance Bronchi, Stavanger, Norway). Thirty experienced anaesthetists and respiratory physicians used a fibreoptic bronchoscope to rate each simulator on a visual analogue scale (VAS) (0 mm = completely unrealistic anatomy, 100 mm = indistinguishable from real patient) for: localisation of the right upper lobe bronchial lumen; placement of a bronchial blocker in the left main bronchus; aspiration of fluid from the right lower lobe; and overall realism. The 3D-printed simulator was rated most realistic for the localisation of the right upper lobe bronchial lumen (p = 0.002), but no differences were found in placement of a bronchial blocker or for aspiration of fluid (p = 0.792 and p = 0.057) compared with using the commercially available simulators. Overall, the 3D-printed simulator was rated most realistic (p = 0.021). Given the substantially lower costs for the 3D-printed simulator (85 pound (Euro100/US$110) compared with > similar to 2000 pound (Euro2350/US$2590) for the commercially available simulators), our 3D-printed simulator provides an inexpensive alternative for learning bronchoscopy skills, and offers the possibility of practising procedures on patient-specific models before attempting them in clinical practice.
引用
收藏
页码:1005 / 1009
页数:5
相关论文
共 16 条
[1]   Development of an Innovative 3D Printed Rigid Bronchoscopy Training Model [J].
Al-Ramahi, Jehad ;
Luo, Huiping ;
Fang, Rui ;
Chou, Adriana ;
Jiang, Jack ;
Kille, Tony .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2016, 125 (12) :965-969
[2]   Assessment of technical skills transfer from the bench training model to the human model [J].
Anastakis, DJ ;
Regehr, G ;
Reznick, RK ;
Cusimano, M ;
Murnaghan, J ;
Brown, M ;
Hutchison, C .
AMERICAN JOURNAL OF SURGERY, 1999, 177 (02) :167-170
[3]  
[Anonymous], 2010, MILLERS ANESTHESIA
[4]   Development of core competencies for an international training programme in intensive care medicine [J].
Barrett, H. ;
Bion, J. F. .
INTENSIVE CARE MEDICINE, 2006, 32 (09) :1371-1383
[5]   Development and Assessment of a Low-Cost 3D-printed Airway Model for Bronchoscopy Simulation Training [J].
Byrne, Timothy ;
Yong, Sarah A. ;
Steinfort, Daniel P. .
JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2016, 23 (03) :251-254
[6]   Fiberoptic Oral Intubation The Effect of Model Fidelity on Training for Transfer to Patient Care [J].
Chandra, Deven B. ;
Savoldelli, Georges L. ;
Joo, Hwan S. ;
Weiss, Israel D. ;
Naik, Viren N. .
ANESTHESIOLOGY, 2008, 109 (06) :1007-1013
[7]   The application of three-dimensional printing technology in anaesthesia: a systematic review [J].
Chao, I. ;
Young, J. ;
Coles-Black, J. ;
Chuen, J. ;
Weinberg, L. ;
Rachbuch, C. .
ANAESTHESIA, 2017, 72 (05) :641-650
[8]   Virtual reality bronchoscopy simulation - A revolution in procedural training [J].
Colt, HG ;
Crawford, SW ;
Galbraith, O .
CHEST, 2001, 120 (04) :1333-1339
[9]   Comparative Effectiveness of Low- and High-Fidelity Bronchoscopy Simulation for Training in Conventional Transbronchial Needle Aspiration and User Preferences [J].
Davoudi, Mohsen ;
Wahidi, Momen M. ;
Rohani, Nazanin Zamanian ;
Colt, Henri G. .
RESPIRATION, 2010, 80 (04) :327-334
[10]   British Thoracic Society guideline for advanced diagnostic and therapeutic flexible bronchoscopy in adults [J].
Du Rand, I. A. ;
Barber, P. V. ;
Goldring, J. ;
Lewis, R. A. ;
Mandal, S. ;
Munavvar, M. ;
Rintoul, R. C. ;
Shah, P. L. ;
Singh, S. ;
Slade, M. G. ;
Woolley, A. .
THORAX, 2011, 66 :1-21