Effect of elevated temperature environments on the residual axial capacity of RC columns strengthened with different techniques

被引:49
作者
Al-Salloum, Yousef A. [1 ]
Almusallam, Tarek H. [1 ]
Elsanadedy, Hussein M. [1 ]
Iqbal, Rizwan A. [1 ]
机构
[1] King Saud Univ, Dept Civil Engn, Coll Engn, MMB Chair Res & Studies Strengthening & Rehabil S, POB 800, Riyadh 11421, Saudi Arabia
关键词
RC columns; Elevated temperature; Strengthening techniques; FRP; TRM; REINFORCED-CONCRETE COLUMNS; ENHANCED SHEAR-STRENGTH; BRIDGE COLUMNS; FRP; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2016.04.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper examines the effect of different elevated temperature environments on performance of reinforced concrete (RC) circular columns strengthened with different techniques. For this purpose, 50 RC circular column specimens were prepared. The test matrix was divided into five groups, of which the first group was composed of 14 unstrengthened columns. The second group consisted of 14 columns strengthened with one layer of continuous carbon fiber reinforced polymer (CFRP) sheet. The third group was composed of 14 columns strengthened with one layer of 5 CFRP strips combined with near surface mounted (NSM) steel bars. Out of the 14 columns in the second or third groups, 4 specimens from each group were insulated using cement-based, fire protection mortar. The fourth group involved 4 columns strengthened with one layer of continuous glass fiber reinforced polymer (GFRP) sheet combined with NSM steel bars. The last group of columns consisted of 4 columns strengthened with continuous textile reinforced mortar (TRM) layers combined with NSM steel bars. It should be noted that strengthened columns of different groups were designed to have approximately the same axial load capacity at ambient temperature. Unstrengthened as well as strengthened columns were subjected to ambient temperature and heating regimes of 100 degrees C, 200 degrees C, 300 degrees C, 400 degrees C, 500 degrees C and 800 degrees C for a period of 3 h. Thereafter, they were left to cool down at ambient temperature and then loaded under uniaxial compression until failure. The behavior and failure modes of different column groups exposed to high degrees of temperature are presented. Comparisons between different strengthening techniques in terms of their resistance to elevated temperature are discussed. (c) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 361
页数:17
相关论文
共 42 条
  • [1] Al-Karaghool H. O., 2013, THESIS AM U SHARJAH
  • [2] Influence of edge sharpness on the strength of square concrete columns confined with FRP composite laminates
    Al-Salloum, Yousef A.
    [J]. COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) : 640 - 650
  • [3] Behavior of FRP-confined concrete after high temperature exposure
    Al-Salloum, Yousef A.
    Elsanadedy, Hussein M.
    Abadel, Aref A.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (02) : 838 - 850
  • [4] [Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
  • [5] [Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
  • [6] [Anonymous], CANULCS101M04
  • [7] [Anonymous], 2009, E8E8M ASTM
  • [8] [Anonymous], 1995, STANDARD TEST METHOD
  • [9] [Anonymous], 2001, E11901 ASTM
  • [10] [Anonymous], 2010, C39C39M ASTM