Development and lab-test of a mobile adsorption air-conditioner

被引:69
作者
Vasta, Salvatore [1 ]
Freni, Angelo [1 ]
Sapienza, Alessio [1 ]
Costa, Fabio [1 ]
Restuccia, Giovanni [1 ]
机构
[1] CNR Ist Tecnol Avanzate Energia Nicola Giordano, I-98126 Messina, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2012年 / 35卷 / 03期
关键词
Adsorption; Air conditioning; Zeolite; Water; WASTE HEAT;
D O I
10.1016/j.ijrefrig.2011.03.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper is focused on the description of a mobile adsorption chiller for cooling in a truck cabin and its experimental performance. The prototype, designed and built at CNR - ITAE, consists of a double-bed adsorber connected with an evaporator and a condenser and driven by the low grade thermal energy coming from the engine coolant loop. Overall volume and weight of the machine are 170 dm(3) and 60 kg, respectively. Performance assessment was preliminarily carried out at ITAE laboratory under the typical EU car air conditioning conditions. The experimental results obtained showed that the system is able to deliver an Average Cooling Power ACP = 1-2.3 kW and a Cooling COP = 0.25-0.45, at a desorption temperature of about 90 degrees C (T-ev similar to 8-14 degrees C and T-con similar to 28-35 degrees C). Afterwards, the cooling system was integrated in a real truck cabin (IVECO STRALIS) and tested on a laboratory test bench, where the engine cooling loop was simulated through an ideal heat source, so demonstrating that the chiller is able to provide cooling comfort to the passengers. (C) 2011 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:701 / 708
页数:8
相关论文
共 15 条
  • [1] Critoph R.E., 2005, P IMECHE E, P219
  • [2] de Boer R., 2008, INT SORPT HEAT PUMP
  • [3] Solar assisted air conditioning of buildings - an overview
    Henning, Hans-Martin
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (10) : 1734 - 1749
  • [4] Hoppler R, 1993, DTSCH KALTE KLIMATES, V14, P31
  • [5] Experimental investigations on adsorption air-conditioner used in internal-combustion locomotive driver-cabin
    Jiangzhou, S
    Wang, RZ
    Lu, YZ
    Xu, YX
    Wu, JY
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (10) : 1153 - 1162
  • [6] Malvicino C., 2008, NEXT GEN MAC WORKSH
  • [7] Meunier F., 2001, Clean Prod. Process, V3, P0008, DOI DOI 10.1007/S100980000096
  • [8] Experimental investigation of a solid adsorption chiller based on a heat exchanger coated with hydrophobic zeolite
    Restuccia, G
    Freni, A
    Russo, F
    Vasta, S
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (10) : 1419 - 1428
  • [9] Sapienza A., 2007, IMPRES INT S INN MAT
  • [10] APPLICATION OF ADSORPTION COOLING SYSTEMS TO AUTOMOBILES
    SUZUKI, M
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (04): : 335 - 340