Platform Switching: Biomechanical Evaluation Using Three-Dimensional Finite Element Analysis

被引:0
作者
Tabata, Lucas Fernando [1 ]
Rocha, Eduardo Passos [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Assuncao, Wirley Goncalves [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Sao Paulo, Brazil
关键词
biomechanics; dental implants; finite element analysis; platform switching; prosthesis; CRESTAL BONE CHANGES; OSSEOINTEGRATED IMPLANTS; TITANIUM IMPLANTS; STRESS-DISTRIBUTION; MARGINAL BONE; SUBMERGED IMPLANTS; FIXED PROSTHESES; SURROUNDING BONE; LENGTH; DIAMETER;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Materials and Methods: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Results: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Conclusion: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:482-491
引用
收藏
页码:482 / 491
页数:10
相关论文
共 54 条
[1]  
Abrahamsson I, 1998, CLIN ORAL IMPLAN RES, V9, P73
[2]   CLINICAL-RESULTS OF OSSEOINTEGRATED IMPLANTS SUPPORTING FIXED PROSTHESES IN EDENTULOUS JAWS [J].
ADELL, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :251-254
[3]  
ALBREKTSSON T, 1986, DENT CLIN N AM, V30, P151
[4]  
Assenza Bartolomeo, 2003, Implant Dent, V12, P235
[5]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[6]  
Barbier L, 1997, INT J ORAL MAX IMPL, V12, P215
[7]   Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs [J].
Becker, Juergen ;
Ferrari, Daniel ;
Herten, Monika ;
Kirsch, Axel ;
Schaer, Alex ;
Schwarz, Frank .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (12) :1089-1096
[8]   Dimension of the periimplant mucosa - Biological width revisited [J].
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) :971-973
[9]  
Bidez M W, 1992, Implant Dent, V1, P289, DOI 10.1097/00008505-199200140-00011
[10]  
Binon PP, 1996, INT J PROSTHODONT, V9, P149