Comparison of different vitrectomy systems

被引:12
作者
Hubschman, JP [1 ]
机构
[1] Espace Helios, ZA Layatz, F-64500 St Jean De Luz, France
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2005年 / 28卷 / 06期
关键词
transconjunctival vitrectomy; 25-gauge vitrectomy; high-speed vitrectomy;
D O I
10.1016/S0181-5512(05)81102-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: The vitrectomy systems in use today have greatly improved from a technical point of view since the introduction of this surgical technique in the 1970s. The TSV 25 (Transconjunctival Standard vitrectomy) using 25-gauge vitrectomy probes and the high-speed vitrectomy module is one of the latest significant advances. This new system does a complete vitrectomy without opening or closing the conjunctiva. Material and method: At the present time, three different aspiration modes (venturi, peristaltic and concentrix), two different probe diameters (20- and 25-gauge) and two cutting modes (pneumatic and high-speed) are available. The author assessed and compared the efficacy of the two different probe diameters and the two different cutting modes available with the venturi pump on the Millennium (Millennium Microsurgical system, Bausch & Lomb, Saint Louis, MO). Results and conclusion: These estimates highlighted the better efficacy of the high-speed cutting mode in comparison to the pneumatical mode. Regarding the probe diameters, the 25-gauge probe is less efficient than the 20-gauge probe. Nevertheless, the flow difference between the two is minimal in comparison to its clinical benefit.
引用
收藏
页码:606 / 609
页数:4
相关论文
共 10 条
[1]   Initial experience using the Transconjunctival Sutureless Vitrectomy System for vitreoretinal surgery [J].
Fujii, GY ;
de Juan, E ;
Humayun, MS ;
Chang, TS ;
Pieramici, DJ ;
Barnes, A ;
Kent, D .
OPHTHALMOLOGY, 2002, 109 (10) :1814-1820
[2]   A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery [J].
Fujii, GY ;
de Juan, E ;
Humayun, MS ;
Pieramici, DJ ;
Chang, TS ;
Ng, E ;
Barnes, A ;
Wu, SL ;
Sommerville, DN .
OPHTHALMOLOGY, 2002, 109 (10) :1807-1812
[3]   VITRECTOMY-INSTRUMENTATION-SYSTEM MS 7 [J].
HENNIG, J .
ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1975, 196 (03) :205-212
[4]   Office-based sutureless transconjunctival pars plana vitrectomy [J].
Hilton, GF ;
Josephberg, RG ;
Halperin, LS ;
Madreperla, SA ;
Brinton, DA ;
Lee, SS ;
Gordon, SF .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (06) :725-732
[5]   NEW CONCEPT FOR VITREOUS SURGERY .7. 2 INSTRUMENT TECHNIQUES IN PARS-PLANA VITRECTOMY [J].
MACHEMER, R .
ARCHIVES OF OPHTHALMOLOGY, 1974, 92 (05) :407-412
[6]  
MACHEMER R, 1972, Transactions of the American Academy of Ophthalmology and Oto-Laryngology, V76, P462
[7]  
Machemer R, 1971, Trans Am Acad Ophthalmol Otolaryngol, V75, P813
[8]  
Machemer R, 1972, Mod Probl Ophthalmol, V10, P172
[9]  
O'Malley C, 1972, Trans Pac Coast Otoophthalmol Soc Annu Meet, V53, P121
[10]  
OMALLEY C, 1977, OPHTHALMIC SURG LAS, V8, P76