Patient-specific blood flow simulation through an aneurysmal thoracic aorta with a folded proximal neck

被引:10
|
作者
Bevan, R. L. T. [1 ]
Sazonov, Igor [1 ]
Saksono, Prihambodo H. [1 ]
Nithiarasu, Perumal [1 ]
van Loon, Raoul [1 ]
Luckraz, Heyman [2 ]
Ashraf, Saeed [3 ,4 ]
机构
[1] Swansea Univ, Coll Engn, Swansea SA2 8PP, W Glam, Wales
[2] Wolverhampton NHS Trust, Heart & Lung Ctr, Wolverhampton, W Midlands, England
[3] Swansea Univ, Sch Med, Swansea SA2 8PP, W Glam, Wales
[4] Morriston Hosp, Dept Cardiothorac Surg, Swansea SA2 8PP, W Glam, Wales
基金
英国工程与自然科学研究理事会;
关键词
thoracic aortic aneurysm; CFD; CBS; wall shear stress; biofluid; FLUID-STRUCTURE INTERACTION; FINITE-ELEMENT-ANALYSIS; WALL STRESS; CBS ALGORITHM; STEADY FLOW; RUPTURE; GENERATION; MODEL; RISK; SCHEME;
D O I
10.1002/cnm.1425
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transient blood flow through a geometrically patient-specific human aorta with a thoracic aortic aneurysm (TAA) is carried out. Special attention is given to the folded neck (kink) of the aneurysm found in the geometry studied. It is a common practice in the UK to intervene when the size of a TAA is between 5.5-6.5 cm. However, the results obtained suggest that neck or any other geometrical features of a TAA may also play a major role in determining the failure of an aortic aneurysm. Thus, we believe that the current practice of intervention needs to be reconsidered and a procedure based on flow classification and geometrical features may be required to minimize mortalities. To establish the effect of the kink, we have compared the results with and without the presence of the kink. The original geometry has been modified to obtain a geometry that is smoother without the kink. The results clearly show a drastic drop in wall shear stress when the kink is smoothed out. This clearly demonstrates that attention must be given to the shape and geometrical features of an aneurysm, in addition to its size. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1167 / 1184
页数:18
相关论文
共 50 条
  • [41] Patient-specific isogeometric fluid-structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device
    Bazilevs, Y.
    Gohean, J. R.
    Hughes, T. J. R.
    Moser, R. D.
    Zhang, Y.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2009, 198 (45-46) : 3534 - 3550
  • [42] 4-D Flow MRI-Based Computational Analysis of Blood Flow in Patient-Specific Aortic Dissection
    Pirola, Selene
    Guo, Baolei
    Menichini, Claudia
    Saitta, Simone
    Fu, Weiguo
    Dong, Zhihui
    Xu, Xiao Yun
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) : 3411 - 3419
  • [43] Multiphysics model for blood flow and drug transport with application to patient-specific coronary artery flow
    Calo, V. M.
    Brasher, N. F.
    Bazilevs, Y.
    Hughes, T. J. R.
    COMPUTATIONAL MECHANICS, 2008, 43 (01) : 161 - 177
  • [44] Patient-specific simulation of high-intensity focused ultrasound for head and neck cancer ablation
    Mohizin, Abdul
    Prasad, Bibin
    Kim, Suzy
    Kim, Jung Kyung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (04) : 2119 - 2130
  • [45] Patient-Specific Multiscale Modeling of Blood Flow for Coronary Artery Bypass Graft Surgery
    Sethuraman Sankaran
    Mahdi Esmaily Moghadam
    Andrew M. Kahn
    Elaine E. Tseng
    Julius M. Guccione
    Alison L. Marsden
    Annals of Biomedical Engineering, 2012, 40 : 2228 - 2242
  • [46] Mass transfer and blood flow in a patient-specific three-dimensional Willis circle
    Pignani, Alessio
    Di Venuta, Ivan
    Boghi, Andrea
    Gori, Fabio
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [47] Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI
    Black, Scott MacDonald
    Maclean, Craig
    Hall Barrientos, Pauline
    Ritos, Konstantinos
    McQueen, Alistair
    Kazakidi, Asimina
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [48] Development of cloud services for patient-specific simulations of blood flows through aortic valves
    Kaceniauskas, A.
    Pacevic, R.
    Starikovicius, V.
    Maknickas, A.
    Staskuniene, M.
    Davidavicius, G.
    ADVANCES IN ENGINEERING SOFTWARE, 2017, 103 : 57 - 64
  • [49] Comparison between Single-Phase Flow Simulation and Multiphase Flow Simulation of Patient-Specific Total Cavopulmonary Connection Structures Assisted by a Rotationally Symmetric Blood Pump
    Chen, Tong
    Liu, Xudong
    Si, Biao
    Feng, Yong
    Zhang, Huifeng
    Jia, Bing
    Wang, Shengzhang
    SYMMETRY-BASEL, 2021, 13 (05):
  • [50] Realistic comparison between aneurysmal wall shear stress vector and blood rheology in patient-specific computational hemodynamic models
    Castro, Marcelo A.
    Ahumada Olivares, Mara C.
    Putman, Christopher M.
    Cebral, Juan R.
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672