Patient-specific blood flow simulation through an aneurysmal thoracic aorta with a folded proximal neck

被引:10
|
作者
Bevan, R. L. T. [1 ]
Sazonov, Igor [1 ]
Saksono, Prihambodo H. [1 ]
Nithiarasu, Perumal [1 ]
van Loon, Raoul [1 ]
Luckraz, Heyman [2 ]
Ashraf, Saeed [3 ,4 ]
机构
[1] Swansea Univ, Coll Engn, Swansea SA2 8PP, W Glam, Wales
[2] Wolverhampton NHS Trust, Heart & Lung Ctr, Wolverhampton, W Midlands, England
[3] Swansea Univ, Sch Med, Swansea SA2 8PP, W Glam, Wales
[4] Morriston Hosp, Dept Cardiothorac Surg, Swansea SA2 8PP, W Glam, Wales
基金
英国工程与自然科学研究理事会;
关键词
thoracic aortic aneurysm; CFD; CBS; wall shear stress; biofluid; FLUID-STRUCTURE INTERACTION; FINITE-ELEMENT-ANALYSIS; WALL STRESS; CBS ALGORITHM; STEADY FLOW; RUPTURE; GENERATION; MODEL; RISK; SCHEME;
D O I
10.1002/cnm.1425
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transient blood flow through a geometrically patient-specific human aorta with a thoracic aortic aneurysm (TAA) is carried out. Special attention is given to the folded neck (kink) of the aneurysm found in the geometry studied. It is a common practice in the UK to intervene when the size of a TAA is between 5.5-6.5 cm. However, the results obtained suggest that neck or any other geometrical features of a TAA may also play a major role in determining the failure of an aortic aneurysm. Thus, we believe that the current practice of intervention needs to be reconsidered and a procedure based on flow classification and geometrical features may be required to minimize mortalities. To establish the effect of the kink, we have compared the results with and without the presence of the kink. The original geometry has been modified to obtain a geometry that is smoother without the kink. The results clearly show a drastic drop in wall shear stress when the kink is smoothed out. This clearly demonstrates that attention must be given to the shape and geometrical features of an aneurysm, in addition to its size. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1167 / 1184
页数:18
相关论文
共 50 条
  • [1] Analysis of flow patterns in a patient-specific thoracic aortic aneurysm model
    Tan, F. P. P.
    Borghi, A.
    Mohiaddin, R. H.
    Wood, N. B.
    Thom, S.
    Xu, X. Y.
    COMPUTERS & STRUCTURES, 2009, 87 (11-12) : 680 - 690
  • [2] Simulation of unsteady blood flow dynamics in the thoracic aorta
    Lain, Santiago
    Caballero, Andres D.
    INGENIERIA E INVESTIGACION, 2017, 37 (03): : 92 - 101
  • [3] Intra-aneurysmal blood flow based on patient-specific CT angiogram
    Taku Morino
    Tetsuya Tanoue
    Satoshi Tateshima
    Fernando Vinuela
    Kazuo Tanishita
    Experiments in Fluids, 2010, 49 : 485 - 496
  • [4] Experience of Patient-Specific CFD Simulation of Blood Flow in Proximal Anastomosis for Femoral-Popliteal Bypass
    Ivanova, Yana
    Yukhnev, Andrey
    Tikhomolova, Ludmila
    Smirnov, Evgueni
    Vrabiy, Andrey
    Suprunovich, Andrey
    Morozov, Alexey
    Khubulava, Gennady
    Vavilov, Valery
    FLUIDS, 2022, 7 (10)
  • [5] NUMERICAL SIMULATION OF BLOOD FLOW IN PATIENT-SPECIFIC STENOTIC CAROTID BIFURCATION GEOMETRIES
    Cummins, Megan
    Rossmann, Jenn S.
    IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 173 - 178
  • [6] Numerical Simulation of Blood Flows in Patient-specific Abdominal Aorta with Primary Organs
    Qin, Shanlin
    Chen, Rongliang
    Wu, Bokai
    Shiu, Wen-Shin
    Cai, Xiao-Chuan
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (03) : 909 - 924
  • [7] Efficient parallel simulation of hemodynamics in patient-specific abdominal aorta with aneurysm
    Qin, Shanlin
    Wu, Bokai
    Liu, Jia
    Shiu, Wen-Shin
    Yan, Zhengzheng
    Chen, Rongliang
    Cai, Xiao-Chuan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 136
  • [8] Patient-specific Blood Flow Simulation to Improve Intracranial Aneurysm Diagnosis
    Fenz, Wolfgang
    Dirnberger, Johannes
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [9] The Impact of Boundary Conditions in Patient-Specific Coronary Blood Flow Simulation
    Uus, Alena
    Liatsis, Panos
    Rajani, Ronak
    Mandic, Lidija
    21ST INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2014), 2014, : 35 - 38
  • [10] Validation of Patient-Specific Cerebral Blood Flow Simulation Using Transcranial Doppler Measurements
    Groen, Derek
    Richardson, Robin A.
    Coy, Rachel
    Schiller, Ulf D.
    Chandrashekar, Hoskote
    Robertson, Fergus
    Coveney, Peter V.
    FRONTIERS IN PHYSIOLOGY, 2018, 9