Numerical investigations of optimal synthesis of several low coherence sources for resolution improvement

被引:10
作者
Zhang, Y
Sato, M
Tanno, N
机构
[1] Yamagata Univ, Grad Sch Sci & Engn, Grad Program Sensing & Funct Sensor Engn, Yonezawa, Yamagata 9928510, Japan
[2] JSTC, Reg Joint Res Project Yamagata Prefecture, Yamagata 9902473, Japan
基金
日本学术振兴会;
关键词
biological imaging; optical coherence tomography; resolution improvement;
D O I
10.1016/S0030-4018(01)01197-X
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A clever method is proposed for optimal synthesis of several low coherence sources to improve the resolution of optical coherence tomography. An optimization algorithm is introduced to arrange the parameters of sources for decreasing the effective coherence length and inhibiting the side lobes simultaneously. Computer simulations are presented to show the features of this new method. The influences of source fluctuations are also investigated. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 15 条
[1]   SIGNAL AND RESOLUTION ENHANCEMENTS IN DUAL BEAM OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN EYE [J].
Baumgartner, Angela ;
Hitzenberger, Christoph K. ;
Sattmann, Harald ;
Drexler, Wolfgang ;
Fercher, Adolf F. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) :45-54
[2]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[3]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[4]   EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT [J].
FERCHER, AF ;
MENGEDOHT, K ;
WERNER, W .
OPTICS LETTERS, 1988, 13 (03) :186-188
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   LASERS IN OPHTHALMOLOGY [J].
KRAUSS, JM ;
PULIAFITO, CA .
LASERS IN SURGERY AND MEDICINE, 1995, 17 (02) :102-159
[7]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[8]   OCT en-face images from the retina with adjustable depth resolution in real time [J].
Podoleanu, AG ;
Rogers, JA ;
Jackson, DA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1176-1184
[9]   SYNTHESIZED SOURCE FOR WHITE-LIGHT SENSING SYSTEMS [J].
RAO, YJ ;
NING, YN ;
JACKSON, DA .
OPTICS LETTERS, 1993, 18 (06) :462-464
[10]   An optical coherence microscope with enhanced resolving power in thick tissue [J].
Schmitt, JM ;
Lee, SL ;
Yung, KM .
OPTICS COMMUNICATIONS, 1997, 142 (4-6) :203-207