Application of Titanium Oxide Decorated Multi-walled Carbon Nanotubes/Polyaniline as a Transducer Polymer for the Potentiometric Determination of Mirtazapine

被引:4
作者
Abdallah, Nehad A. [1 ,2 ]
机构
[1] Taibah Univ, Coll Pharm, Pharmacognosy & Pharmaceut Chem Dept, Al Madinah Al Mounawarah 30078, Saudi Arabia
[2] Ain Shams Univ, Fac Pharm, Expt & Adv Pharmaceut Res Unit, Cairo 11566, Egypt
关键词
Carbon nanotubes; nanoparticles; polyaniline; potentiometry; sensors; CHROMATOGRAPHY-MASS SPECTROMETRY; ION-SELECTIVE ELECTRODES; HUMAN PLASMA; LIQUID-CHROMATOGRAPHY; ANTIDEPRESSANT MIRTAZAPINE; VALIDATED METHOD; PHASE MICROEXTRACTION; WHOLE-BLOOD; METABOLITES; MEMBRANE;
D O I
10.1002/slct.202202985
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recently, mortality linked to the intake of the antidepressant mirtazapine (MTZ) together with other drugs has been recently detected, and measuring the MTZ concentration in biological fluids has become crucial. The proposed electrode is thought to be the first potentiometric carbon paste electrode for quantifying MTZ in various biological matrices. It is based on the covalent polymerization of the aniline monomers onto the surface of the multi-walled carbon nanotubes (MWCNTs) /TiO2 nanocomposite to be applied as an ion-to-electron transducer element with 18-crown-6-ether as a recognition element. The MWCNTs/TiO2/Polyaniline (PANI) composite was characterized by XRD and FT-IR. The electrode demonstrated a wide linearity range of 1x10(-7) M to 1x10(-2) M with a Nernstian slope of 59.76 +/- 1.55 mV/concentration decade and a LOD of 3.2x10(-8) M. It was successfully applied for the determination of MTZ in spiked plasma, urine, and artificial cerebrospinal fluid without any significant interference from matrix components, with average recovery, ranged from 97.91 % to 99.31 %.
引用
收藏
页数:8
相关论文
共 52 条
[1]   Solid-Contact ISE for the Potentiometric Determination of Melitracen Hydrochloride in Pharmaceutical Tablets and Human Plasma [J].
Abdallah, Nehad A. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (04)
[2]   Electrochemical determination of Saxagliptin hydrochloride with MWCNTs/ CuO/4′aminobenzo-18-crown-6-ether composite modified carbon paste electrode [J].
Abdallah, Nehad A. ;
Ibrahim, Heba F. .
MICROCHEMICAL JOURNAL, 2019, 147 :487-496
[3]  
Agin F, 2013, MACED J CHEM CHEM EN, V32, P41
[4]  
[Anonymous], 2007, NATL FORMULARY, V3, P2671
[5]   A fast, sensitive and simple method for mirtazapine quantification in human plasma by HPLC-ESI-MS/MS. Application to a comparative bioavailability study [J].
Borges, Ney Carter ;
Barrientos-Astigarraga, Rafael Eliseo ;
Sverdloff, Carlos Eduardo ;
Donato, Jose Luiz ;
Moreno, Patricia ;
Felix, Leila ;
Rebelo Galvinas, Paulo Alexandre ;
Moreno, Ronilson Agnaldo .
BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) :1399-1407
[6]   Poisoning suicide with ingestion of the pyrethroids alpha-cypermethrin and deltamethrin and the antidepressant mirtazapine: A case report [J].
Boumba, Vassiliki A. ;
Rallis, Georgios N. ;
Vougiouklakis, Theodore .
FORENSIC SCIENCE INTERNATIONAL, 2017, 274 :75-78
[7]   Determination of clozapine, and five antidepressants in human plasma, serum and whole blood by gas chromatography-mass spectrometry: A simple tool for clinical and postmortem toxicological analysis [J].
Boumba, Vassiliki A. ;
Rallis, George ;
Petrikis, Petros ;
Vougiouklakis, Theodore ;
Mavreas, Venetsanos .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1038 :43-48
[8]   A Validated Method for the Simultaneous Determination of Quetiapine, Clozapine and Mirtazapine in Postmortem Blood and Tissue Samples [J].
Breivik, Havard ;
Lokken, Trine N. ;
Slordal, Lars ;
Frost, Joachim .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2020, 44 (05) :440-448
[9]   ALL-SOLID-STATE SODIUM-SELECTIVE ELECTRODE BASED ON A CALIXARENE IONOPHORE IN A POLY(VINYL CHLORIDE) MEMBRANE WITH A POLYPYRROLE SOLID CONTACT [J].
CADOGAN, A ;
GAO, ZQ ;
LEWENSTAM, A ;
IVASKA, A ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2496-2501
[10]  
Darwish H.W., 2016, J CHEM-NY, V2016, P1