Performance enhancement of a desiccant evaporative cooling system using direct/indirect evaporative cooler

被引:49
作者
Elgendy, E. [1 ]
Mostafa, A. [1 ]
Fatouh, M. [1 ]
机构
[1] Helwan Univ, Fac Engn El Mattaria, Dept Power Mech Engn, Cairo, Egypt
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2015年 / 51卷
关键词
Desiccant evaporative cooler; Air conditioning; Exergy; Hot and humid climate; Desiccant wheel; 1ST;
D O I
10.1016/j.ijrefrig.2014.12.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, three novel desiccant evaporative cooling system configurations are proposed, simulated and compared with the conventional system under a wide range of ambient air temperature (30: 40 degrees C) and humidity ratio (0.01: 0.02 kg(v) kg(a)(-1)). In configuration-I, a direct/indirect evaporative cooling is inserted before the rotating heat exchanger. However, it is inserted after the rotating heat exchanger for system configuration-II. In configuration-III, an extra direct/indirect evaporative cooling is added in an opposite manner. Validation results confirm that, simulation and experimental results are in a good agreement with average errors of 2.23 and 3.87% for ambient air temperature and humidity ratio, respectively. Energetic analysis revealed that configuration-I has the highest cooling capacity while configuration-III has the highest thermal COP and air handling COP. Exergetic efficiency of config-III is higher than the conventional system with 54% as average value over the range of ambient air humidity. (C) 2014 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 19 条
[1]  
[Anonymous], 2014, EES ENG EQUATION SOL
[2]  
Beckman W. A., 2004, TRNSYS 16 REFERENCE
[3]   Comparison between the conventional and recirculation modes in desiccant cooling cycles and deriving critical efficiencies of components [J].
Bourdoukan, P. ;
Wurtz, E. ;
Joubert, P. .
ENERGY, 2010, 35 (02) :1057-1067
[4]   Chilled ceiling and displacement ventilation aided with personalized evaporative cooler [J].
Chakroun, W. ;
Ghaddar, N. ;
Ghali, K. .
ENERGY AND BUILDINGS, 2011, 43 (11) :3250-3257
[5]  
Dunkle R. V., 1975, MECH CHEM ENG T MC, VMC1
[6]   Experimental study on a two-stage rotary desiccant cooling system [J].
Ge, T. S. ;
Li, Y. ;
Wang, R. Z. ;
Dai, Y. J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03) :498-508
[7]   The effects of operational conditions of the desiccant wheel on the performance of desiccant cooling cycles [J].
Heidarinejad, Ghassem ;
Pasdarshahri, Hadi .
ENERGY AND BUILDINGS, 2010, 42 (12) :2416-2423
[8]   OPEN-CYCLE DESICCANT AIR-CONDITIONING AS AN ALTERNATIVE TO VAPOR COMPRESSION COOLING IN RESIDENTIAL APPLICATIONS [J].
JURINAK, JJ ;
MITCHELL, JW ;
BECKMAN, WA .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03) :252-260
[9]   HIGH-PERFORMANCE, SOLID DESICCANT, OPEN COOLING CYCLES [J].
KANG, TS ;
MACLAINECROSS, IL .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (02) :176-183
[10]   Effect of ambient conditions on the first and second law performance of an open desiccant cooling process [J].
Kanoglu, Mehmet ;
Bolatturk, Ali ;
Altuntop, Necdet .
RENEWABLE ENERGY, 2007, 32 (06) :931-946