Bioimpedance spectroscopy: Is a picture worth a thousand words?

被引:2
|
作者
Mohamed, Maha [1 ]
Matthie, Jim [2 ]
Fan, Stanley L. [1 ]
机构
[1] Barts Hlth NHS Trust, Dept Renal Med & Transplantat, London, England
[2] Matthie Consulting, La Jolla, CA USA
关键词
PERITONEAL-DIALYSIS PATIENTS; GUIDED FLUID MANAGEMENT; LEFT-VENTRICULAR MASS; BODY-COMPOSITION; BIOELECTRICAL-IMPEDANCE; NATRIURETIC PEPTIDE; LUNG ULTRASOUND; VOLUME CONTROL; MULTIFREQUENCY BIOIMPEDANCE; INDEPENDENT PREDICTOR;
D O I
10.1111/sdi.13084
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Volume status can be difficult to assess in dialysis patients. Peripheral edema, elevated venous pressure, lung crackles, and hypertension are taught as signs of fluid overload, but sensitivity and specificity are poor. Bioimpedance technology has evolved from early single frequency to multifrequency machines which apply spectroscopic analysis (BIS), modeling data to physics-based mixture theory. Bioimpedance plots can aid the evaluation of hydration status and body composition. The challenge remains how to use this information to manage dialysis populations, particularly as interventions to improve over hydration, sarcopenia, and adiposity are not without side effects. It is therefore of no surprise that validation studies for BIS use in peritoneal dialysis patients are limited, and results from clinical trials are inconsistent and conflicting. Despite these limitations, BIS has clinical utility with potential to accurately evaluate small changes in body tissue components. This article explains the information a BIS plot ("picture") can provide and how it can contribute to the overall clinical assessment of a patient. However, it remains the role of the clinician to integrate information and devise treatment strategies to optimize competing patient risks, fluid and nutrition status, effects of high glucose PD fluids on membrane function, and quality of life issues.
引用
收藏
页码:71 / 81
页数:11
相关论文
共 50 条
  • [21] Bioimpedance spectroscopy: A technique to monitor interventions for swelling in minor burns
    Kenworthy, Pippa
    Grisbrook, Tiffany L.
    Phillips, Michael
    Gittings, Paul
    Wood, Fiona M.
    Gibson, William
    Edgar, Dale W.
    BURNS, 2017, 43 (08) : 1725 - 1735
  • [22] Implementation of Single-Tab Electrodes for Bioimpedance Spectroscopy Measures
    Donahue, Paula M. C.
    Crescenzi, Rachelle
    Du, Liping
    Donahue, Manus J.
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (03) : 277 - 283
  • [23] Using Bioimpedance Spectroscopy to Assess Volume Status in Dialysis Patients
    Hussein, Rasha H.
    Calice-Silva, Viviane
    Evans, Rhys
    Levin, Nathan W.
    Ellidir, Rashid A.
    Ali, Elitigani M.
    Bakhiet, Yassir
    Ahmed, Amna
    Abdelkareem, Asmaa
    Abdelraheem, Mohamed B.
    Kotanko, Peter
    Pecoits-Filho, Roberto
    Raimann, Jochen G.
    BLOOD PURIFICATION, 2020, 49 (1-2) : 185 - 196
  • [24] Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
    Grisbrook, T. L.
    Kenworthy, P.
    Phillips, M.
    Gittings, P. M.
    Wood, F. M.
    Edgar, D. W.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (10) : 2189 - 2201
  • [25] Assessment of bioimpedance spectroscopy devices: a comparative study and error analysis of gold-plated copper electrodes
    Mussnig, Sebastian
    Krenn, Simon
    Hecking, Manfred
    Wabel, Peter
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (02)
  • [26] The Effect of Strict Volume Control Assessed by Repeated Bioimpedance Spectroscopy on Cardiac Function in Peritoneal Dialysis Patients
    Hong, Yu Ah
    Yoon, Hye Eun
    Choi, Bum Soon
    Shin, Seok Joon
    Kim, Yong-Soo
    Lee, So Young
    Lee, Sang-Ho
    Kim, Su Hyun
    Lee, Eun Young
    Shin, Sug Kyun
    Kwon, Young Joo
    Kim, Jeong Ho
    Chang, Yoon Kyung
    Kim, Suk Young
    Kim, Ji Eun
    Ahn, Shin Young
    Ko, Gang Jee
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [27] Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy
    Edwick, Dale O.
    Hince, Dana A.
    Rawlins, Jeremy M.
    Wood, Fiona M.
    Edgar, Dale W.
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (06) : 560 - 571
  • [28] Volume Control in Peritoneal Dialysis Patients Guided by Bioimpedance Spectroscopy Assessment
    Luo, Ya-Jun
    Lu, Xin-Hong
    Woods, Feidhlim
    Wang, Tao
    BLOOD PURIFICATION, 2011, 31 (04) : 296 - 302
  • [29] Design of Bioimpedance Spectroscopy Instrument With Compensation Techniques for Soft Tissue Characterization
    Dodde, Robert E.
    Kruger, Grant H.
    Shih, Albert J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (02): : 1 - 8
  • [30] Influence of peritoneal dialysis solution on measurements of fluid status by bioimpedance spectroscopy
    Parmentier, Simon Paul
    Schirutschke, Holger
    Schmitt, Bertram
    Schewe, Jens
    Herbrig, Kay
    Pistrosch, Frank
    Passauer, Jens
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2013, 45 (01) : 229 - 232