Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk

被引:29
作者
Chivukula, Venkat Keshav [1 ]
Beckman, Jennifer A. [2 ]
Li, Song [2 ]
Masri, S. Carolina [2 ]
Levy, Wayne C. [2 ]
Lin, Shin [2 ]
Cheng, Richard K. [2 ]
Farris, Stephen D. [2 ]
Wood, Gregory [2 ]
Dardas, Todd F. [2 ]
Kirkpatrick, James N. [2 ]
Koomalsingh, Kevin [3 ]
Zimpfer, Daniel [4 ]
Mackensen, G. Burkhard [5 ]
Chassagne, Fanette [1 ]
Mahr, Claudius [2 ]
Aliseda, Alberto [1 ]
机构
[1] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[2] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[3] Univ Washington, Div Cardiothorac Surg, Seattle, WA 98195 USA
[4] Univ Vienna, Div Cardiothorac Surg, Vienna, Austria
[5] Univ Washington, Div Cardiac Anesthesia, Seattle, WA 98195 USA
关键词
mechanical circulatory support; inflow cannula insertion depth; thrombogenic potential; hemodynamics; Lagrangian metrics; virtual surgery; shear stress history; residence time; MECHANICAL CIRCULATORY SUPPORT; BODY-SURFACE-AREA; HEART-FAILURE; AORTIC-VALVE; CARDIOVASCULAR DEVICES; PLATELET ACTIVATION; SIZE MATTER; BLOOD-FLOW; PUMP; HEMODYNAMICS;
D O I
10.1097/MAT.0000000000001068
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Left ventricular assist device (LVAD) use has continued to grow. Despite recent advances in technology, LVAD patients continue to suffer from devastating complications, including stroke and device thrombosis. Among several variables affecting thrombogenicity, we hypothesize that insertion depth of the inflow cannula into the left ventricle (LV) influences hemodynamics and thrombosis risk. Blood flow patterns were studied in a patient-derived computational model of the LV, mitral valve (MV), and LVAD inflow cannula using unsteady computational fluid dynamics (CFD). Hundreds of thousands of platelets were tracked individually, for two inflow cannula insertion depth configurations (12 mm-reduced and 27 mm-conventional) using platelet-level (Lagrangian) metrics to quantify thrombogenicity. Particularly in patients with small LV dimensions, the deeper inflow cannula insertion resulted in much higher platelet shear stress histories (SH), consistent with markedly abnormal intraventricular hemodynamics. A larger proportion of platelets in this deeper insertion configuration was found to linger in the domain for long residence times (RT) and also accumulated much higher SH. The reduced inflow depth configuration promoted LV washout and reduced platelet SH. The increase of both SH and RT in the LV demonstrates the impact of inflow cannula depth on platelet activation and increased stroke risk in these patients. Inflow cannula depth of insertion should be considered as an opportunity to optimize surgical planning of LVAD therapy.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 69 条
[1]   Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies [J].
Alemu, Yared ;
Bluestein, Danny .
ARTIFICIAL ORGANS, 2007, 31 (09) :677-688
[2]   LVAD Outflow Graft Angle and Thrombosis Risk [J].
Aliseda, Alberto ;
Chivukula, Venkat Keshav ;
Mcgah, Patrick ;
Prisco, Anthony R. ;
Beckman, Jenifer A. ;
Garcia, Guilherme J. M. ;
Mokadam, Nahush A. ;
Mahr, Claudius .
ASAIO JOURNAL, 2017, 63 (01) :14-23
[3]   Right heart failure post left ventricular assist device implantation [J].
Argiriou, Mihalis ;
Kolokotron, Styliani-Maria ;
Sakellaridis, Timothy ;
Argiriou, Orestis ;
Charitos, Christos ;
Zarogoulidis, Paul ;
Katsikogiannis, Nikolaos ;
Kougioumtzi, Ioanna ;
Machairiotis, Nikolaos ;
Tsiouda, Theodora ;
Tsakiridis, Kosmas ;
Zarogoulidis, Konstantinos .
JOURNAL OF THORACIC DISEASE, 2014, 6 :S52-S59
[4]   A Practical Approach to Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention An Interventional Perspective [J].
Atkinson, Tamara M. ;
Ohman, E. Magnus ;
O'Neill, William W. ;
Rab, Tanveer ;
Cigarroa, Joaquin E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (09) :871-883
[5]  
Benjamin EJ, 2017, CIRCULATION, V135, pE146, DOI [10.1161/CIR.0000000000000485, 10.1161/CIR.0000000000000558, 10.1161/CIR.0000000000000530]
[6]   DOES LVAD INFLOW CANNULA POSITION CONTRIBUTE TO THE DEVELOPMENT OF PUMP THROMBOSIS REQUIRING DEVICE EXCHANGE? [J].
Bhama, Jay ;
Eckert, Chad ;
Lockard, Kathleen ;
Shiose, Akira ;
Bermudez, Christian ;
Teuteberg, Jeffrey ;
Ramani, Ravi ;
Simon, Marc ;
Badhwar, Vinay ;
Kormos, Robert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) :E719-E719
[7]   Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage [J].
Bianchi, Matteo ;
Marom, Gil ;
Ghosh, Ram P. ;
Rotman, Oren M. ;
Parikh, Puja ;
Gruberg, Luis ;
Bluestein, Danny .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2019, 18 (02) :435-451
[8]   Pump thrombosis-A riddle wrapped in a mystery inside an enigma [J].
Blitz, Arie .
ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (05) :450-471
[9]   Numerical simulation of left ventricular assist device implantations: Comparing the ascending and the descending aorta cannulations [J].
Bonnemain, Jean ;
Malossi, A. Cristiano I. ;
Lesinigo, Matteo ;
Deparis, Simone ;
Quarteroni, Alfio ;
von Segesser, Ludwig K. .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) :1465-1475
[10]   Hemodynamics of Mechanical Circulatory Support [J].
Burkhoff, Daniel ;
Sayer, Gabriel ;
Doshi, Darshan ;
Uriel, Nir .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (23) :2664-2674