A fouling model for simulating long-term performance of SWRO desalination process

被引:31
作者
Lee, Young Geun [2 ]
Lee, Yun Seok [1 ]
Kim, Do Yeon [3 ]
Park, Minkyu [1 ]
Yang, Dae Ryook [3 ]
Kim, Joon Ha [1 ,4 ,5 ]
机构
[1] Gwangju Inst Sci & Technol, Sch Environm Sci & Engn, Kwangju 500712, South Korea
[2] Doosan Heavy Ind & Construct Co Ltd, Water BG, Gyeongsangnamdo 642792, South Korea
[3] Korea Univ, Dept Chem & Biol Engn, Seoul 136701, South Korea
[4] GIST, Ctr Seawater Desalinat Plant, Kwangju 500712, South Korea
[5] GIST, Sustainable Water Resource Technol Ctr, Kwangju 500712, South Korea
基金
新加坡国家研究基金会;
关键词
Fouling model; Membrane resistance; Concentration polarization; Cleaning; Replacement; Membrane maintenance; O&M; REVERSE-OSMOSIS; CONCENTRATION POLARIZATION; ULTRAFILTRATION; SYSTEM;
D O I
10.1016/j.memsci.2012.02.016
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A fouling model for the seawater reverse osmosis (SWRO) process is required to propose an appropriate strategy for membrane maintenance (i.e., membrane cleaning and replacement). In this study, a fouling model that considered the concentration polarization was properly developed to simulate the long-term performance of the SWRO process based on models from the literature. The model was practically applied to one-year operation data obtained from the Fujairah SWRO desalination plant with parameter estimation, and good agreement between the measured data and simulated results was obtained for both the rejection and recovery rates. Compared to an integrated model consisting of two models from the literature, the fouling model proposed in this study showed reliable performance for membrane fouling such as the increase in the permeate TDS concentration according to operating time. In addition, simulations for membrane maintenance were conducted based on the variation in membrane resistance, which reflects the fouling state of the membrane. These revealed that the rearrangement of membranes is not significantly effective without cleaning the fouled membrane. Instead, a partial replacement of membranes can be an effective maintenance scheme to increase the recovery rate. Accordingly, the results of the study presented here can be used to save operation and maintenance (O&M) costs in SWRO plants through the optimized management of fouled membranes. (C) 2012 Elsevier B. V. All rights reserved.
引用
收藏
页码:282 / 291
页数:10
相关论文
共 23 条
[1]   FOULING PREDICTION IN REVERSE-OSMOSIS PROCESSES [J].
BARGER, M ;
CARNAHAN, RP .
DESALINATION, 1991, 83 (1-3) :3-33
[2]  
Beier S.P., 2007, Pressure driven membrane processes
[3]   MODELING OF ULTRAFILTRATION - PREDICTIONS OF CONCENTRATION POLARIZATION EFFECTS [J].
BOUCHARD, CR ;
CARREAU, PJ ;
MATSUURA, T ;
SOURIRAJAN, S .
JOURNAL OF MEMBRANE SCIENCE, 1994, 97 :215-229
[4]   The development of membrane fouling in full-scale RO processes [J].
Chen, KL ;
Song, LF ;
Ong, SL ;
Ng, WJ .
JOURNAL OF MEMBRANE SCIENCE, 2004, 232 (1-2) :63-72
[5]  
Chou Y., 1975, Statistical Analysis
[6]   Studies on organic foulants in the seawater feed of reverse osmosis plants of SWCC [J].
Dalvi, AGI ;
Al-Rasheed, R ;
Javeed, MA .
DESALINATION, 2000, 132 (1-3) :217-232
[7]   State-of-the-art of reverse osmosis desalination [J].
Fritzmann, C. ;
Loewenberg, J. ;
Wintgens, T. ;
Melin, T. .
DESALINATION, 2007, 216 (1-3) :1-76
[8]   Influence of crossflow membrane filter geometry and shear rate on colloidal fouling in reverse osmosis and nanofiltration separations [J].
Hoek, EMV ;
Kim, AS ;
Elimelech, M .
ENVIRONMENTAL ENGINEERING SCIENCE, 2002, 19 (06) :357-372
[9]   Modeling the effects of fouling on full-scale reverse osmosis processes [J].
Hoek, Eric M. V. ;
Allred, Jeff ;
Knoell, Tom ;
Jeong, Byeong-Heon .
JOURNAL OF MEMBRANE SCIENCE, 2008, 314 (1-2) :33-49
[10]   FOULING OF CELLULOSE-ACETATE TUBULAR REVERSE-OSMOSIS MODULES TREATING INDUSTRIAL WATER IN TOKYO [J].
KIMURA, S ;
NAKAO, SI .
DESALINATION, 1975, 17 (03) :267-288