Assessment of next generation refrigerants for air conditioning systems integrated with air-membrane heat and mass exchangers

被引:4
作者
Al-Sulaiman, Fahad A. [1 ,2 ]
机构
[1] KFUPM, Res Inst, CoRERE, Dhahran 31261, Saudi Arabia
[2] KFUPM, Mech Engn Dept, Dhahran 31261, Saudi Arabia
关键词
Air conditioning system; Potential refrigerants; Heat and mass exchanger; Exergy analysis; Energy recovery; Coefficient of performance; DEHUMIDIFICATION SYSTEMS; ENTHALPY EXCHANGER; ENERGY PERFORMANCE; RECOVERY; HYBRID; SIMULATION;
D O I
10.1016/j.enconman.2017.10.032
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermodynamic analysis was conducted, in detail, to compare the performance of an air conditioning system with and without an air-membrane heat and mass exchanger. The study evaluated the performance of the system considering four promising new refrigerants: R1234yf, R1234ze, R32, and R423A. To evaluate the performance of the system, key performance parameters were used, including, coefficient of performance (COP), exergy destruction rate, second law efficiency, compressor work, irreversibility ratio, fuel depletion ratio, and productivity lack. In addition, the effect of varying the compressor pressure ratio, effectiveness of the membrane, and the relative humidity of fresh air on the performance of the system were evaluated for both configurations. The performance of an air conditioning system significantly improves when an air-membrane heat and mass exchanger is used. The main reason of this improvement is the significant drop in the cooling load and, consequently, the compressor input power. Furthermore, the study showed that COP as a measure of performance is not enough to have an appropriate comparison for the performance and further detailed analysis is needed, such as exergy analysis. Therefore, exergy analysis was also conducted to fully assess the advantages of using a membrane with an air conditioning system. From thermodynamics point of view, the study showed that R1234ze has the best performance while R32 has the lowest performance.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 28 条
[1]   Thermodynamic analysis of an innovative liquid desiccant air conditioning system to supply potable water [J].
Ahmed, M. A. ;
Gandhidasan, P. ;
Zubair, Syed M. ;
Bahaidarah, Haitham M. .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :161-173
[2]   Energy and Exergy Analyses of an Air Membrane Heat and Mass Exchanger for Air Conditioning Applications [J].
Al-Sulaiman, Fahad A. .
JOURNAL OF ENERGY ENGINEERING, 2017, 143 (05)
[3]   Techno-economic analysis of solar-assisted air-conditioning systems for commercial buildings in Saudi Arabia [J].
Al-Ugla, A. A. ;
El-Shaarawi, M. A. I. ;
Said, S. A. M. ;
Al-Qutub, A. M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 :1301-1310
[4]   CFD simulation of air to air enthalpy heat exchanger [J].
Al-Waked, Rafat ;
Nasif, Mohammad Shakir ;
Morrison, Graham ;
Behnia, Masud .
ENERGY CONVERSION AND MANAGEMENT, 2013, 74 :377-385
[5]   CO2-assisted compression-adsorption hybrid for cooling and desalination [J].
Ali, Syed Murtuza ;
Chakraborty, Anutosh ;
Leong, Kai Choong .
ENERGY CONVERSION AND MANAGEMENT, 2017, 143 :538-552
[6]   Life cycle assessment and economic analysis of residential air conditioning in Saudi Arabia [J].
Almutairi, Kamel ;
Thoma, Greg ;
Burek, Jasmina ;
Algarni, Salem ;
Nutter, Darin .
ENERGY AND BUILDINGS, 2015, 102 :370-379
[7]   Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies [J].
Angrisani, Giovanni ;
Roselli, Carlo ;
Sasso, Maurizio .
APPLIED ENERGY, 2015, 138 :533-545
[8]   Simulation of potential standalone liquid desiccant cooling cycles [J].
Das, Rajat Subhra ;
Jain, Sanjeev .
ENERGY, 2015, 81 :652-661
[9]  
Dincer I, 2013, EXERGY ENERGY ENV SU
[10]   A novel air conditioning system - Membrane air drying and evaporative cooling [J].
El-Dessouky, HT ;
Ettouney, HM ;
Bouhamra, W .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A7) :999-1009