Endovascular Treatment of Posterior Cerebral Artery Aneurysms With Flow Diversion: Case Series and Systematic Review

被引:22
作者
Wallace, Adam N. [1 ,2 ]
Grossberg, Jonathan A. [3 ]
Almandoz, Josser E. Delgado [1 ]
Kamran, Mudassar [4 ]
Roy, Anil K. [3 ]
Kayan, Yasha [1 ]
Austin, Matthew J. [4 ]
Howard, Brian M. [3 ]
Moran, Christopher J. [4 ,5 ]
Cawley, C. Michael [3 ]
Cross, DeWitte T. [4 ,5 ]
Dion, Jacques E. [6 ]
Kansagra, Akash P. [4 ,5 ,7 ]
Osbun, Joshua W. [4 ,5 ,7 ]
机构
[1] Abbott Northwest Hosp, Neurosci Inst, Div Neurointervent Radiol, 800 E 28th St, Minneapolis, MN 55407 USA
[2] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[3] Emory Univ, Dept Neurosurg, Atlanta, GA 30322 USA
[4] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO USA
[5] Washington Univ, Dept Neurosurg, St Louis, MO USA
[6] Emory Univ, Dept Radiol, Atlanta, GA USA
[7] Washington Univ, Dept Neurol, St Louis, MO USA
关键词
Aneurysm; Flow diverter; Stroke; Hemorrhage; Angiography; PIPELINE EMBOLIZATION DEVICE; SINGLE-CENTER EXPERIENCE; TERM-FOLLOW-UP; UNRUPTURED INTRACRANIAL ANEURYSMS; CIRCULATION ANEURYSMS; DIVERTOR; OCCLUSION; SURPASS; WILLIS; CIRCLE;
D O I
10.1093/neuros/nyx561
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Flow diversion of posterior cerebral artery (PCA) aneurysms has not been widely reported, possibly owing to concerns regarding parent vessel size and branch vessel coverage. OBJECTIVE: To examine the safety and effectiveness of PCA aneurysm flow diverter treatment. METHODS: Retrospective review of PCAaneurysms treated with the Pipeline Embolization Device (PED; Medtronic Inc, Dublin, Ireland) at 3 neurovascular centers, including periprocedural complications and clinical and angiographic outcomes. Systematic review of the literature identified published reports of PCA aneurysms treated with flow diversion. Rates of aneurysm occlusion and complications were calculated, and outcomes of saccular and fusiform aneurysm treatments were compared. RESULTS: Ten PCA aneurysms in 9 patients were treated with the PED. There were 2 intraprocedural thromboembolic events (20%), including 1 symptomatic infarction and 1 delayed PED thrombosis. Eight of 10 patients returned to or improved fromtheir baseline functional status. Complete aneurysm occlusion with parent vessel preservation was achieved in 75% (6/8) of cases at mean follow-up of 16.7 mo. Eleven of 12 (92%) major branch vessels covered by a PED remained patent. Including the present study, systematic review of 15 studies found a complete aneurysmocclusion rate of 88% (30/34) and complication rate of 26% (10/38), including 5 symptomatic ischemic strokes (13%; 5/38). Fusiform aneurysms more frequently completely occluded compared with saccular aneurysms (100% vs 70%; P =.03) but were associated with a higher complication rate (43% vs 9%; P =.06). CONCLUSION: The safety and effectiveness profile of flow diverter treatment of PCA aneurysms may be acceptable in select cases.
引用
收藏
页码:790 / 799
页数:10
相关论文
共 41 条
  • [1] Treatment of intracranial aneurysms by embolization with coils - A systematic review
    Brilstra, EH
    Rinkel, GJE
    van der Graaf, Y
    van Rooij, WJJ
    Algra, A
    [J]. STROKE, 1999, 30 (02) : 470 - 476
  • [2] Safety and efficacy of the Pipeline Embolization Device in 100 small intracranial aneurysms
    Chalouhi, Nohra
    Zanaty, Mario
    Whiting, Alex
    Yang, Steven
    Tjoumakaris, Stavropoula
    Hasan, David
    Starke, Robert M.
    Hann, Shannon
    Hammer, Christine
    Kung, David
    Rosenwasser, Robert
    Jabbour, Pascal
    [J]. JOURNAL OF NEUROSURGERY, 2015, 122 (06) : 1498 - 1502
  • [3] Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device
    Chiu, A. H. Y.
    Cheung, A. K.
    Wenderoth, J. D.
    De Villiers, L.
    Rice, H.
    Phatouros, C. C.
    Singh, T. P.
    Phillips, T. J.
    McAuliffe, W.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (09) : 1728 - 1734
  • [4] Ciceri EF, 2001, AM J NEURORADIOL, V22, P27
  • [5] Immediate procedural outcomes in 44 consecutive Pipeline Flex cases: the first North American single-center series
    Colby, Geoffrey P.
    Lin, Li-Mei
    Caplan, Justin M.
    Jiang, Bowen
    Huang, Judy
    Tamargo, Rafael J.
    Coon, Alexander L.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (07) : 702 - 709
  • [6] Pipeline Embolization Device in the Treatment of Recurrent Previously Stented Cerebral Aneurysms
    Daou, B.
    Starke, R. M.
    Chalouhi, N.
    Tjoumakaris, S.
    Hasan, D.
    Khoury, J.
    Rosenwasser, R. H.
    Jabbour, P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (05) : 849 - 855
  • [7] New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms A Prospective Single-Center Study in 37 Patients
    De Vries, Joost
    Boogaarts, Jeroen
    Van Norden, Anouk
    Wakhloo, Ajay K.
    [J]. STROKE, 2013, 44 (06) : 1567 - 1577
  • [8] Delgado Almandoz Josser E, 2013, BMJ Case Rep, V2013, DOI 10.1136/bcr-2012-010634
  • [9] Coiling of Intracranial Aneurysms A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates
    Ferns, Sandra P.
    Sprengers, Marieke E. S.
    van Rooij, Willem Jan
    Rinkel, Gabriel J. E.
    van Rijn, Jeroen C.
    Bipat, Shandra
    Sluzewski, Menno
    Majoie, Charles B. L. M.
    [J]. STROKE, 2009, 40 (08) : E523 - E529
  • [10] Pipeline Embolization Device for Small Intracranial Aneurysms: Evaluation of Safety and Efficacy in a Multicenter Cohort
    Griessenauer, Christoph J.
    Ogilvy, Christopher S.
    Foreman, Paul M.
    Chua, Michelle H.
    Harrigan, Mark R.
    He, Lucy
    Fusco, Matthew R.
    Mocco, J. D.
    Stapleton, Christopher J.
    Patel, Aman B.
    Sonig, Ashish
    Siddiqui, Adnan H.
    Thomas, Ajith J.
    [J]. NEUROSURGERY, 2017, 80 (04) : 579 - 587