Physically Tailoring Ion Fluxes by Introducing Foamlike Structures into Polymeric Membranes of Solid Contact Ion-Selective Electrodes

被引:8
作者
Cheong, Yi Heng [1 ,2 ,3 ]
Lisak, Grzegorz [1 ,2 ]
机构
[1] Nanyang Technol Univ, Coll Engn, Sch Civil & Environm Engn, Singapore 639798, Singapore
[2] Nanyang Environm & Water Res Inst, Residues & Resource Reclamat Ctr, Singapore 637141, Singapore
[3] Robert Bosch South East Asia Pte Ltd, Singapore 573943, Singapore
关键词
ion-selective electrode; potential stability; potential reproducibility; membrane modification; ion fluxes; LOWER DETECTION LIMIT; WATER LAYER; POTENTIOMETRIC SENSORS; DIFFUSION; TRANSPORT; RECOMMENDATIONS; COEFFICIENTS; TRANSDUCER; CHALLENGES; GRAPHENE;
D O I
10.1021/acssensors.1c01413
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Transmembrane ion fluxes have earlier been identified as a source of potential instability in solid contact ion-selective electrodes (SC-ISEs). In this work, foamlike structures were intentionally introduced into a potassium-sensitive plasticized poly(vinyl chloride) ion-selective membrane (ISM) near the membrane vertical bar solid contact interface by controlling the temperature during membrane deposition. Foamlike structures in the ISM were shown to be effective at physically tailoring the transport of ions in the ion-selective membrane, greatly reducing the flux of interfering ions from the sample to the membrane vertical bar solid contact interface. The drifts during a conventional water layer test were hence able to be greatly mitigated, even with SC-ISEs incorporating a relatively hydrophilic poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) solid contact. In solutions with a high background concentration of interfering ions, equilibrated ion-selective electrodes with foamlike membranes were able to reproduce their initial potentials within 0.6 mV uncertainty (n = 3) from 0 to 18 h. This was achieved despite sensor exposure to solutions exceeding the selectivity limit of the ISEs in 3 h intervals, allowing improvement of the potential reproducibility of the sensors. Since the introduction of foamlike structures into ISM is linked to temperature-controlled membrane deposition, it is envisaged that the method is generally applicable to all solid contact ion-selective electrodes that are based on polymeric membranes and require membrane deposition from the cocktail solution.
引用
收藏
页码:3667 / 3676
页数:10
相关论文
共 70 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[3]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[4]   Use of ion-selective electrodes for blood-electrolyte analysis.: Recommendations for nomenclature, definitions and conventions [J].
Burnett, RW ;
Covington, AK ;
Fogh-Andersen, N ;
Külpmann, WR ;
Lewenstam, A ;
Maas, AHJ ;
Müller-Plathe, O ;
VanKessel, AL ;
Zijlstra, WG .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (04) :363-370
[5]   Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes [J].
Ceresa, A ;
Sokalski, T ;
Pretsch, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2) :70-76
[6]   Highly reproducible solid contact ion selective electrodes: Emerging opportunities for potentiometry - A review [J].
Cheong, Yi Heng ;
Ge, Liya ;
Lisak, Grzegorz .
ANALYTICA CHIMICA ACTA, 2021, 1162 (1162)
[7]   Ion selective electrodes utilizing a ferrocyanide doped redox active screen-printed solid contact - impact of electrode response to conditioning [J].
Cheong, Yi Heng ;
Ge, Liya ;
Zhao, Nahong ;
Teh, Lay Kuan ;
Lisak, Grzegorz .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 870
[8]   All-solid-state potentiometric sensors: A new wave for in situ aquatic research [J].
Cuartero, Maria ;
Crespo, Gaston A. .
CURRENT OPINION IN ELECTROCHEMISTRY, 2018, 10 :98-106
[9]   Environmental water analysis with membrane electrodes [J].
Cuartero, Maria ;
Bakker, Eric .
CURRENT OPINION IN ELECTROCHEMISTRY, 2017, 3 (01) :97-105
[10]   Evidence of a water layer in solid-contact polymeric ion sensors [J].
De Marco, Roland ;
Veder, Jean-Pierre ;
Clarke, Graeme ;
Nelson, Andrew ;
Prince, Kathryn ;
Pretsch, Erno ;
Bakker, Eric .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2008, 10 (01) :73-76