Numerical simulation of blood flow in a flexible stenosed abdominal real aorta

被引:29
作者
Alishahi, M. [1 ]
Alishahi, M. M. [1 ,2 ]
Emdad, H. [1 ,2 ]
机构
[1] Shiraz Univ, Sch Engn, Dept Mech Engn, Shiraz, Iran
[2] Shiraz Univ, Dept Fluid Mech, Shiraz, Iran
关键词
Pulsatile; Blood flow; Stenosis; Abdominal aorta; Flexible wall; FLUID-STRUCTURE INTERACTION; NON-NEWTONIAN FLUID; UNSTEADY-FLOW; CAROTID BIFURCATION; MASS-TRANSFER; MODELS; SHEAR;
D O I
10.1016/j.scient.2011.11.021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study concerns an evaluation of pulsatile flow and arterial wall behavior in a real world model of a stenosed abdominal aorta and iliac arteries. Two different geometries of a healthy and severly stenosed abdominal aorta, extracted from CT scan images and simulations of fluid flow and tissue interaction (Fluid Solid Interaction), are carried out. The blood is taken as incompressible, non-Newtonian, and the arterial wall tissue is treated as isotropic, elastic material with uniform mechanical properties. The results of using two models with rigid and flexible walls are presented and compared. The computed pressure at the abdominal aorta for a flexible healthy wall is consistent with measured values in vivo conditions. Results show that the computed pressure is lower by 15% for the flexible model, as compared to the rigid and complaint models. Although results obtained from the FSI study of pulsatile healthy and stenosed models show a similar trend for Wall Shear Stress (WSS) patterns, considerable differences in magnitude exist. It is shown that for the cases presented here, the effects of wall flexibility and actual stenosed geometry on the flow performance of veins are noticeable. (C) 2012 Sharif University of Technology. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 23 条
[1]  
[Anonymous], 2007, ANSYS CFX REL 11 0
[2]  
*ANSYS, 2007, REL 11 0 DOC ANSYS
[3]   Blood flow patterns in an anatomically realistic coronary vessel: Influence of three different reconstruction methods [J].
Berthier, B ;
Bouzerar, R ;
Legallais, C .
JOURNAL OF BIOMECHANICS, 2002, 35 (10) :1347-1356
[4]   ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS [J].
CARO, CG ;
FITZGERA.JM ;
SCHROTER, RC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046) :109-+
[5]  
Fung Y.C., 1984, Biodynamics Circulation
[6]   Simulation and validation of arterial ultrasound imaging and blood flow [J].
Hoskins, Peter R. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (05) :693-717
[7]   CHARACTERIZATION AND EVOLUTION OF POST-STENOTIC FLOW DISTURBANCES [J].
KHALIFA, AMA ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1981, 14 (05) :279-296
[8]   Modelling of flow and wall behaviour in a mildly stenosed tube [J].
Lee, KW ;
Xu, XY .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (09) :575-586
[9]   A comparison between different asymmetric abdominal aortic aneurysm morphologies employing computational fluid-structure interaction analysis [J].
Li, Zhonghua ;
Kleinstreuer, Clement .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2007, 26 (05) :615-631
[10]  
McDonald DA., 1974, BLOOD FLOW ARTERIES