IMPACT OF FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY PULMONARY VENTILATION IMAGING-BASED FUNCTIONAL AVOIDANCE FOR LUNG CANCER RADIOTHERAPY

被引:120
作者
Yamamoto, Tokihiro [1 ]
Kabus, Sven [2 ]
von Berg, Jens [2 ]
Lorenz, Cristian [2 ]
Keall, Paul J. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[2] Philips Res Europe, Dept Digital Imaging, Hamburg, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2011年 / 79卷 / 01期
关键词
Lung cancer; functional imaging; four-dimensional computed tomography; 4D-CT; intensity-modulated radiotherapy; IMRT; volumetric modulated arc therapy; VMAT; INTENSITY-MODULATED RADIOTHERAPY; RADIATION PNEUMONITIS; REGIONAL VENTILATION; THERAPY; SPECT; CT; REGISTRATION; TOXICITY; IMRT; IRRADIATION;
D O I
10.1016/j.ijrobp.2010.02.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify the dosimetric impact of four-dimensional computed tomography (4D-CT) pulmonary ventilation imaging-based functional treatment planning that avoids high-functional lung regions. Methods and Materials: 4D-CT ventilation images were created from 15 non-small-cell lung cancer patients using deformable image registration and quantitative analysis of the resultant displacement vector field. For each patient, anatomic and functional plans were created for intensity-modulated radiotherapy own and volumetric modulated arc therapy (VMAT). Consistent beam angles and dose-volume constraints were used for all cases. The plans with Radiation Therapy Oncology Group (RTOG) 0617-defined major deviations were modified until clinically acceptable. Functional planning spared the high-functional lung, and anatomic planning treated the lungs as uniformly functional. We quantified the impact of functional planning compared with anatomic planning using the two- or one-tailed t test. Results: Functional planning led to significant reductions in the high-functional lung dose, without significantly increasing other critical organ doses, but at the expense of significantly degraded the planning target volume (PTV) conformity and homogeneity. The average reduction in the high-functional lung mean dose was 1.8 Gy for IMRT (p < .001) and 2.0 Gy for VMAT (p < .001). Significantly larger changes occurred in the metrics for patients with a larger amount of high-functional lung adjacent to the PTV. Conclusion: The results of the present study have demonstrated the impact of 4D-CT ventilation imaging-based functional planning for IMRT and VMAT for the first time. Our findings indicate the potential of functional planning in lung functional avoidance for both IMRT and VMAT, particularly for patients who have high-functional lung adjacent to the PTV. (C) 2011 Elsevier Inc.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 29 条
[1]   Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry [J].
Christensen, Gary E. ;
Song, Joo Hyun ;
Lu, Wei ;
El Naqa, Issarn ;
Low, Daniel A. .
MEDICAL PHYSICS, 2007, 34 (06) :2155-2163
[2]   The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer [J].
Christian, JA ;
Partridge, M ;
Nioutsikou, E ;
Cook, G ;
McNair, HA ;
Cronin, B ;
Courbon, F ;
Bedford, JL ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (03) :271-277
[3]  
Guerrero T, 2006, PHYS MED BIOL, V51, P777, DOI [10.1088/0031-9155/51/4/002, 10.1088/0031-9155/-51/4/002]
[4]   Quantification of regional ventilation from treatment planning CT [J].
Guerrero, T ;
Sanders, K ;
Noyola-Martinez, J ;
Castillo, E ;
Zhang, Y ;
Tapia, R ;
Guerra, R ;
Borghero, Y ;
Komaki, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :630-634
[5]  
KABUS S, 2008, P 1 INT WORKSH PULM, P73
[6]   Objective assessment of deformable image registration in radiotherapy: A multi-institution study [J].
Kashani, Rojano ;
Hub, Martina ;
Balter, James M. ;
Kessler, Marc L. ;
Dong, Lei ;
Zhang, Lifei ;
Xing, Lei ;
Xie, Yaoqin ;
Hawkes, David ;
Schnabel, Julia A. ;
McClelland, Jamie ;
Joshi, Sarang ;
Chen, Quan ;
Lu, Weiguo .
MEDICAL PHYSICS, 2008, 35 (12) :5944-5953
[7]   MRI using hyperpolarized noble gases [J].
Kauczor, HU ;
Surkau, R ;
Roberts, T .
EUROPEAN RADIOLOGY, 1998, 8 (05) :820-827
[8]   Final toxicity results of a radiation-dose escalation study in patients with non-small-cell lung cancer (NSCLC): Predictors for radiation pneumonitis and fibrosis [J].
Kong, Feng-Ming ;
Hayman, James A. ;
Griffith, Kent A. ;
Kalemkerian, Gregory P. ;
Arenberg, Douglas ;
Lyons, Susan ;
Turrisi, Andrew ;
Lichter, Allen ;
Fraass, Benedick ;
Eisbruch, Avraham ;
Lawrence, Theodore S. ;
Ten Haken, Randall K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :1075-1086
[9]   Non-small cell lung cancer therapy-related pulmonary toxicity: An update on radiation pneumonitis and fibrosis [J].
Kong, FM ;
Ten Haken, R ;
Eisbruch, A ;
Lawrence, TS .
SEMINARS IN ONCOLOGY, 2005, 32 (02) :S42-S54
[10]   VOLUMETRIC MODULATED ARC RADIOTHERAPY FOR VESTIBULAR SCHWANNOMAS [J].
Lagerwaard, Frank J. ;
Meijer, Otto W. M. ;
van der Hoorn, Elles A. P. ;
Verbakel, Wilko F. A. R. ;
Slotman, Ben J. ;
Senan, Suresh .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :610-615