Fiber Bragg grating sensor for monitoring bone decalcification

被引:26
作者
Mishra, V. [1 ]
Singh, N. [1 ]
Rai, D. V. [2 ]
Tiwari, U. [1 ]
Poddar, G. C. [1 ]
Jain, S. C. [1 ]
Mondal, S. K. [1 ]
Kapur, P. [1 ]
机构
[1] CSIR, Cent Sci Instruments Org, Chandigarh 160030, India
[2] Shobhit Univ, Inst Engn & Technol, Ctr Biomed Engn, Meerut 250110, Uttar Pradesh, India
关键词
Fiber Bragg Grating; Decalcification; Bending strain; STRAIN; EXERCISES;
D O I
10.1016/j.otsr.2010.04.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Estimation of decalcification is a vital tool to discern bone health. Different techniques are used for its quantitative measurement, e. g. DEXA, QCT & QUS. All these techniques, although noninvasive, suffer from limitations such as radiation exposure and inaccurate values. Recently, fiber optic techniques are fast emerging for medical applications owing to their various attractive features like immunity to EMI/RFI, geometric versatility, chemical inertness, etc. Material and methods: The effect of decalcification on strain response of a goat tibia was investigated in vitro using fiber Bragg grating (FBG) sensing technique. The bone was strained by using three-point bending technique and corresponding Bragg wavelength shifts were recorded. Two similar bone samples from the same animal were taken and one was partially decalcified. Strain response of decalcified and untreated bone was taken concurrently to monitor the effects of calcium loss and that of degradation with time. Results and conclusion: The strain generated for same stress increased with greater degree of decalcification and a steep increase occurred after 2 g calcium loss, indicating the onset of damage. The strain response, therefore gives a direct indication of the degree of calcium present in the bone. Level of evidence: Level III. (c) 2010 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:646 / 651
页数:6
相关论文
共 24 条
[1]   Strength and size of bone in relation to calcium intake [J].
Bell, GH ;
Cuthbertson, DP ;
Orr, J .
JOURNAL OF PHYSIOLOGY-LONDON, 1941, 100 (03) :299-317
[2]   Application of Bragg grating sensors in dental biomechanics [J].
Carvalho, L. ;
Silva, J. C. C. ;
Nogueira, R. N. ;
Pinto, J. L. ;
Kalinowski, H. J. ;
Simoes, J. A. .
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2006, 41 (06) :411-416
[3]   Ex vivo measurement of lumbar intervertebral disc pressure using fibre-Bragg gratings [J].
Dennison, Christopher R. ;
Wild, Peter M. ;
Byrnes, Peter W. G. ;
Saari, Amy ;
Itshayek, Eyal ;
Wilson, Derek C. ;
Zhu, Qingan A. ;
Dvorak, Marcel F. S. ;
Cripton, Peter A. ;
Wilson, David R. .
JOURNAL OF BIOMECHANICS, 2008, 41 (01) :221-225
[4]   Fibre optic Bragg grating sensors: An alternative method to strain gauges for measuring deformation in bone [J].
Fresvig, T. ;
Ludvigsen, P. ;
Steen, H. ;
Reikeras, O. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (01) :104-108
[5]  
Kashyap R., 1999, Fiber Bragg Gratings
[6]  
MILCZESWKI MS, 2006, 5 INT C MECH MAT DES
[7]   Are overground or treadmill runners more likely to sustain tibial stress fracture? [J].
Milgrom, C ;
Finestone, A ;
Segev, S ;
Olin, C ;
Arndt, T ;
Ekenman, I .
BRITISH JOURNAL OF SPORTS MEDICINE, 2003, 37 (02) :160-163
[8]   In vivo strain measurements to evaluate the strengthening potential of exercises on the tibial bone [J].
Milgrom, C ;
Finestone, A ;
Simkin, A ;
Ekenman, I ;
Mendelson, S ;
Millgram, M ;
Nyska, M ;
Larsson, E ;
Burr, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (04) :591-594
[9]   Do high impact exercises produce higher tibial strains than running? [J].
Milgrom, C ;
Finestone, A ;
Levi, Y ;
Simkin, A ;
Ekenman, I ;
Mendelson, S ;
Millgram, M ;
Nyska, M ;
Benjuya, N ;
Burr, D .
BRITISH JOURNAL OF SPORTS MEDICINE, 2000, 34 (03) :195-199
[10]  
Mishra V., 2009, TRENDS MEDICAL PHYS, P225