Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold

被引:52
作者
Hori, Y
Yamada, N
Higashi, M
Hirai, N
Nakatani, S
机构
[1] Natl Cardiovasc Ctr, Dept Radiol & Nucl Med, Suita, Osaka 5658565, Japan
[2] Natl Cardiovasc Ctr, Cardiol Div Med, Suita, Osaka 5658565, Japan
关键词
magnetic resonance (MR); Cine study; volume measurement; heart; real time; True FISP; STEADY-STATE PRECESSION; EJECTION FRACTION; MAGNETIC-RESONANCE; DIASTOLIC FUNCTION; REPRODUCIBILITY; VOLUME; ECHOCARDIOGRAPHY; ANGIOGRAPHY; ACCURACY; SMASH;
D O I
10.1081/JCMR-120022260
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both real-time multislice True-FISP cine imaging without breath-hold and single-slice segmented True-FISP cine imaging with multiple breath-holds were performed in short-axis imaging sections to encompass the entire ventricles. Vertical long-axis cine imaging using real-time True-FISP cine sequence without breath-hold was performed to evaluate heart motion during respiration in 13 subjects. Ventricular volume and mass were evaluated by four observers independently with manual tracing. Results. Real-time True-FISP cine quality was sufficient for contour detection in all 24 subjects. Cardiodynamic measurements based on real-time True-FISP cine correlated well with those based on segmented True-FISP cine [left ventricular (LV) end-diastolic volume: r = 0.98; LV end-systolic volume: r = 0.98; LV ejection fraction: r = 0.91; LV mass: r = 0.96; right ventricular (RV) end-diastolic volume: r = 0.89; RV end-systolic volume: r = 0.94; RV ejection fraction: r = 0.79]. Intra- and interobserver variability were sufficiently small in real-time True-FISP cine without breath-hold. Heart motion during respiration along the long axis of the left ventricle (2.2 mm to 3.7 mm) was much less than the slice interval (10 mm), confirming that misregistration of slice position during respiration was low. Conclusion. Real-time True-FISP cine without breath-hold has high reproducibility and is applicable to patients with severe cardiac dysfunction and/or arrhythmias.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 34 条
[1]   RELATION OF TRANSMITRAL FLOW VELOCITY PATTERNS TO LEFT-VENTRICULAR DIASTOLIC FUNCTION - NEW INSIGHTS FROM A COMBINED HEMODYNAMIC AND DOPPLER ECHOCARDIOGRAPHIC STUDY [J].
APPLETON, CP ;
HATLE, LK ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :426-440
[2]   ANGIOCARDIOGRAPHIC DETERMINATION OF LEFT VENTRICULAR VOLUME [J].
ARVIDSSON, H .
ACTA RADIOLOGICA, 1961, 56 (05) :321-&
[3]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[4]   DIRECT QUANTITATION OF RIGHT AND LEFT-VENTRICULAR VOLUMES WITH NUCLEAR-MAGNETIC-RESONANCE IMAGING IN PATIENTS WITH PRIMARY PULMONARY-HYPERTENSION [J].
BOXT, LM ;
KATZ, J ;
KOLB, T ;
CZEGLEDY, FP ;
BARST, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1508-1515
[5]   Reproducibility study of left ventricular measurements with breath-hold cine MRI using a semiautomated volumetric image analysis program [J].
Butler, SP ;
McKay, E ;
Paszkowski, AL ;
Quinn, RJ ;
Shnier, RC ;
Donovan, JT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02) :467-472
[6]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[7]   USE OF BIPLANE CINEFLUOROGRAPHY FOR MEASUREMENT OF VENTRICULAR VOLUME [J].
CHAPMAN, CB ;
BAKER, O ;
REYNOLDS, J ;
BONTE, FJ .
CIRCULATION, 1958, 18 (06) :1105-1117
[8]   REPRODUCIBILITY OF ANGIOGRAPHIC LEFT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
COHN, PF ;
LEVINE, JA ;
BERGERON, GA ;
GORLIN, R .
AMERICAN HEART JOURNAL, 1974, 88 (06) :713-720
[9]   CARDIAC EJECTION FRACTION - PHANTOM STUDY COMPARING CINE MR IMAGING, RADIONUCLIDE BLOOD POOL IMAGING, AND VENTRICULOGRAPHY [J].
DEBATIN, JF ;
NADEL, SN ;
PAOLINI, JF ;
SOSTMAN, HD ;
COLEMAN, RE ;
EVANS, AJ ;
BEAM, C ;
SPRITZER, CE ;
BASHORE, TM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :135-142
[10]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776